Summary
B0600191
Building Permit - Commercial
Certificate of Occupancy
AFZALI MOJAN
CHANGE OF TENANT
ALTER BUILDING TO DENTIST OFFICE
02/15/2006
03/02/2006
08/29/2006
05/31/2006
Locations
Contacts
NADER AFZALI, Address:11828 ROE AVE  
AFZALI MOJAN, Address:13002 WALMER ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/29/2006 10/29/2010
Correction

Fire Department- IFC 3006.2 Interior supply location. Medical gases shall be stored in areas dedicated to the storage of such gases without other storage or uses. Where containers of medical gases in quantities greater than the permit amount are located inside buildings, they shall be in a 1-hour exterior room, a 1-hour interior room or a gas cabinet in accordance with Section 3006.2.1, 3006.2.2 or 3006.2.3. 3006.2.1 One-hour exterior rooms. A 1-hour exterior room shall be a room or enclosure separated from the remainder of the building by fire barriers with a fire-resistance rating of not less than 1 hour. Openings between the room or enclosure and interior spaces shall be self-closing smokeand draft-control assemblies having a fire protection rating of not less than 1 hour. Rooms shall have at least one exterior wall that is provided with at least two vents. Each vent shall not be less than 36 square inches (0.023 m2) in area. One vent shall be within 6 inches (152 mm) of the floor and one shall be within 6 inches (152 mm) of the ceiling. Rooms shall be provided with at least one automatic sprinkler to provide container cooling in case of fire.
Correction

Fire Department-IFC 3006.4 Medical gas systems. Medical gas systems including, but not limited to, distribution piping, supply manifolds, connections, pressure regulators, and relief devices and valves, shall comply with NFPA 99 and the general provisions of this chapter.
Correction

Fire Department- Provide information on the type and quantity of medical gas to be stored in the building.
Correction

Fire Department; IFC 1003.3.1.8 Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type.
Correction

Codes Administration - 2002 NEC 517.13 - Grounding of receptacles and fixed electric equipment in patient care areas. Wiring in patient care areas shall comply with 517.13 (A) and (B).
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IPC 607.3.2 - Backflow prevention device or check valve. Where a backflow prevention device, check valve or other device is installed on a water supply system utilizing storage water heating equipment such that thermal expansion causes an increase in pressure, a device for controlling pressure shall be installed.
Correction

Codes Administration - 2003 IPC 608.16.9 - Dental pump equipment. Where dental pumping equipment connects to the water distribution system, the water supply system shall be protected against backflow in accordance with Section 608.13.1, 608.13.2, 608.13.5, 608.13.6 or 608.13.8.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $46.19 $46.19 Paid 03/02/2006
89 Sewer Tap Fees $390.00 $390.00 Paid 03/02/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Partial 03/22/2006
Correction
Partial Correction
03/22/2006
UNDER-SLAB DWV & WATER PIPING AT TR #3 COPPER PIPING HAS BEEN DAMAGED; REPLACE DAMAGED SECTION OK TO COVER WHEN READY EXCEPT @ TR #3
Underslab Electrical Inspection - Commercial Passed 03/22/2006
Correction
Resolved
03/22/2006
UNDER-FLOOR ELECTRICAL CONDUIT/BOXES OK TO COVER WHEN READY
Underslab Plumbing Inspection - Commercial Passed 03/23/2006
Correction
Resolved
03/23/2006
UNDER-SLAB DWV & WATER PIPING OK TO COVER WHEN READY
All Rough Inspection - Commercial Passed 04/12/2006
Correction
Resolved
04/12/2006
None OKAY TO INSULATE, OKAY TO ROCK
Above Ceiling Inspection Passed 05/08/2006
Correction
Resolved
05/08/2006
NEW ADDITIONS TO ABOVE-CEILING SYSTEMS OK TO COVER WHEN READY
Occupancy Inspection - Codes Commercial Failed 05/23/2006
Correction
Resolved
05/23/2006
Receive Fire Department approval OK PER JOE DIR 5/23/06
Correction
Corrective Action Required
05/23/2006
Receive Water Utilities Approval TO BEN HASKAMP @ L.S. WATER UTILITIES (CARD PROVIDED) PROVIDE TEST RESULTS FOR BACKFLOW PREVENTION
Correction
Corrective Action Required
05/23/2006
WATER CLOSET SEATS IPC 420.3 NOT COMMERCIAL TYPE WITH OPEN FRONT
Correction
Corrective Action Required
05/23/2006
MOLD ON GYPSUM WALLBOARD @ WATER SERVICE ENTRY REPLACE AFFECTED GWB AFTER LEAK IS ELIMINATED
Correction
Corrective Action Required
05/23/2006
ELECTRICAL RECEPTACLE @ MICROWAVE OVEN SHELF BOX NOT FLUSH WITH COMBUSTIBLE WALL SURFACE
Correction
Corrective Action Required
05/23/2006
OVERSIZE GWB CUTOUT FOR ELECTRICAL RECEPTACLE ROOM @ NORTH/NORTHWEST
Correction
Corrective Action Required
05/23/2006
HOOKUP OF EQUIPMENT SUBJECT TO APPROVAL
Occupancy Inspection - Codes Commercial Failed 05/26/2006
Correction
Partial Correction
05/26/2006
Receive Water Utilities Approval TO BEN HASKAMP @ L.S. WATER UTILITIES (CARD PROVIDED); SUBMIT NO LATER THAN OPENING FOR BUSINESS 5/30/06. BACKFLOW PREVENTION DEVICE AT SERVICE ENTRY LEAKING -- TO BE REPLACED. PROVIDE TEST RESULTS FOR BACKFLOW PREVENTION
Correction
Resolved
05/26/2006
WATER CLOSET SEATS
Correction
Resolved
05/26/2006
MOLD ON GYPSUM WALLBOARD @ WATER SERVICE ENTRY AFFECTED AREA OF GWB REPLACED W/ GREEN BOARD
Correction
Resolved
05/26/2006
ELECTRICAL RECEPTACLE @ MICROWAVE OVEN SHELF
Correction
Resolved
05/26/2006
OVERSIZE GWB CUTOUT FOR ELECTRICAL RECEPTACLE
Correction
Partial Correction
05/26/2006
HOOKUP OF EQUIPMENT IN PROGRESS SUBJECT TO APPROVAL
Occupancy Inspection - Codes Commercial Passed 05/30/2006
Correction
Resolved
05/30/2006
Receive Water Utilities Approval PER BEN HASKAMP 5/30/06
Correction
Resolved
05/30/2006
HOOKUP OF EQUIPMENT
Correction
Resolved
05/30/2006
BACKFLOW PREVENTION NO APPARENT VIOLATION OF INTERNATIONAL PLUMBING CODE, IN COJUNCTION WITH NATIONAL CENTER FOR CHRONIC DISEASE PREVENTION AND HEALTH PROMOTION "FACT SHEET" ISSUED JANUARY 2002. DENTAL PROFESSIONAL IS RESPONSIBLE TO MAINTAIN BACKFLOW PREVENTION AT DENTAL OPERATIVE UNITS AND AT VACUUM PUMP
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home