Permit Application Status

B0600053


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0600053
Building Permit - Commercial
Certificate of Occupancy
TI SUMMIT CREST PLAZA LLC
NEW TENANT FINISH
TENANT FINISH
01/13/2006
01/30/2006
07/29/2006
03/08/2006
Locations
Contacts
CRAIG A LUEBBERT, ARCHITECT, LLC, Address:230 SW MAIN ST STE 203  
DOCS ORIGINAL COFFEE HOUSE, Address:3524 SW MARKET ST  
TI SUMMIT CREST PLAZA LLC, Address:7611 STATE LINE RD STE 301  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/26/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1008.1.8.1 - Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 shall not require tight grasping, tight pinching or twisting of the wrist to operate.
Correction

Codes Administration - 2003 IBC 1110.1 - Signs. Required accessible elements shall be identified by the International Symbol of Accessiblity a the following locations: 1. Accessible parking spaces required by Section 1106.1 except where the total number of parking spaces provided is four or less. 2. Accessible passenger loading zones. 3. Accessbile areas of refuge required by Section 1007.6. 4. Accessible rooms where multiple single-user toilet or bathing rooms are clustered in a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the checkout aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting and locker rooms where not all such rooms are accessible.
Correction

Codes Administration - The project cost has not been provided. This information is required for permit fee calculation.
Correction

Codes Administration - 2003 IBC 303.1.1 - Nonacessory assembly use. A building or tenant space used for assembly purposes by less than 50 persons shall be considered a Group B occupancy.
Correction

Codes Administration - The original shell building was reviewed as a Type V-B construction, non-separated uses with increases for distance to property lines and the sprinkler system. The plans submitted show a construction type of II-B.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Codes Administration - For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

Codes Administration - For the Health Department permit approval contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Plan approval is required by the City of Lee's Summit prior to issuance of any type of permit.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IMC 403.3 - Ventilation rate. Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and occupant load or other parameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less than the number determined fron the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall b designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

Codes Administration - 2003 IMC 501.2 - Outdoor discharge. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic or crawl space.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Lee's Summit Code of Ordinances, Section 17-6.D - Regulated smoking environments classified. No persons with ownership, management, or control of a food service establishment shall operate such establishment unless there is posted signage at a height and location conspicuous to persons entering the establishment, eith primary lettering of not less than one inch in height according to one of the following classifications of food service establishments: 1. Smoke-free establishment (existing and new establishments) 2. Smoking establishment (existing establishments only) 3. Mixed smoking/non-smoking establishment (existing establishments only) 4. Smoking restricted establishment (existing and new establishments)
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $30.00 $30.00 Paid 01/30/2006
0120 Building Permit Fee $95.29 $95.29 Paid 01/30/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 02/09/2006
Correction
Resolved
02/09/2006
None UNDERSLAB PLUMBING APPROVED
Underslab Electrical Inspection - Commercial Passed 02/10/2006
Correction
Resolved
02/10/2006
None UNDERSLAB ELECTRICAL APPROVED
Rough Electrical Inspection - Commercial Passed 02/15/2006
Correction
Resolved
02/15/2006
IN-WALL ELECTRICAL ROUGH-IN
Rough Plumbing Inspection - Commercial Passed 02/15/2006
Rough Plumbing Inspection - Commercial Passed 02/16/2006
Correction
Resolved
02/16/2006
None IN-WALL ROUGH PLUMBING APPROVED
Rough Electrical Inspection - Commercial Passed 02/22/2006
Correction
Resolved
02/22/2006
ELECTRICAL ROUGH IN COUNTERTOP
Occupancy Inspection - Codes Commercial Failed 03/06/2006
Correction
Corrective Action Required
03/06/2006
Receive Fire Department approval
Correction
Corrective Action Required
03/06/2006
CONNECT ABOVE-CEILING DVW VENTING TO VENT STACK THROUGH ROOF ALSO SUPPORT VENT PVC EVERY 4 FT
Correction
Corrective Action Required
03/06/2006
SHALL VENT ALL BATHFANS TO EXTERIOR
Correction
Corrective Action Required
03/06/2006
CAP OPENINGS AT ABOVE-CEILING ELECTRICAL BOXES
Correction
Corrective Action Required
03/06/2006
BATHROOM -MIRROR:MAXIMUM 40" ABOVE FLOOR -PROVIDE OPEN FRONT TOILET SEATS -TOILET PAPER DISPENSER OUTLET:MIN 12" ABOVE GRAP BAR AND MAX 48" ABOVE FLOOR
Rough Plumbing Inspection - Commercial Passed 03/07/2006
Rough Electrical Inspection - Commercial Passed 03/07/2006
Occupancy Inspection - Codes Commercial Passed 03/07/2006
Correction
Resolved
03/07/2006
Receive Fire Department approval
Correction
Resolved
03/07/2006
CONNECT ABOVE-CEILING DVW VENTING TO VENT STACK THROUGH ROOF
Correction
Resolved
03/07/2006
SHALL VENT ALL BATHFANS TO EXTERIOR
Correction
Resolved
03/07/2006
CAP OPENINGS AT ABOVE-CEILING ELECTRICAL BOXES
Correction
Resolved
03/07/2006
BATHROOM
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents