Summary
B0600032
Building Permit - Commercial
Certificate of Occupancy
GALE COMMUNITIES INC
NEW TENANT FINISH
TENANT FINISH
01/09/2006
02/07/2006
08/06/2006
10/13/2006
Locations
Contacts
TIMOTHY P DEVINE RA, Address:12733 W 82ND STREET  
MAUR CO, Address:6618 W 141ST TER #2405  
GALE COMMUNITIES INC, Address:400 SW LONGVIEW BLVD STE 210, Phone:(816) 645-2336  
GALE COMMUNITIES INC, Address:400 SW LONGVIEW BLVD STE 105  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/05/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1004.1 - Design occupant load. In determining means of egress requirements, the number of occupants for whom meansof egress facilities shall be provided shall be established by the largest number computed in accordance with Sections 1004.1.1 through 1004.1.3.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

Codes Administration - The mechanical plans reference the 1997 UMC. The City of Lee's Summit has adopted the 2003 IMC.
Correction

Codes Administration - The finish notes provided are not consistant with the notes on the floor plans.
Correction

Codes Administration - The allowable area for the shell building was calculated using none separated uses. This will allow for the tenant spaces to be constructed without fire-rated assemblies between them.
Correction

Codes Administration - The plans indicate an occupancy type of M which is a mercantile occupancy. Based on the use of this space the Codes Administration staff believes the space to most resemble a B occupancy.
Correction

Codes Administration - The shell building was classified as Type V-B construction. This tenant finish has the construction Type as II-B.
Correction

Codes Administration - The City of Lee's Summit will not issue any type of certificate of occupancy for this tenant space until Fascination Drive and Longview Road are completed and approved by the Public Works Inspection Department.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm-initiating and notification appli- ances.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Codes Administration - 2003 IBC 1109.12.1 - Dressing, fitting and locker rooms. Where dressing rooms, fitting rooms or locker rooms are provided, at least 5 percent, but not less than one, of each type of use in each cluster provided shall be accessible.
Correction

Codes Administration - 2003 IBC 1004.3 - Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

Codes Administration - 2003 IPC 403.1 - Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. Types of occupancies not shown in Tale 403.1 shall be considered individually by the code official. The number of occupants shall be deetermined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $136.28 $136.28 Paid 02/07/2006
89 Sewer Tap Fees $120.00 $120.00 Paid 02/07/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 02/08/2006
All Rough Inspection - Commercial Failed 02/21/2006
Correction
Corrective Action Required
02/21/2006
BOXES INCOMPLETE ELECTRICAL BOXES TO BE "MADE-UP" FOR INSPECTION OF GROUNDING AND CONNECTION METHODS
Correction
Corrective Action Required
02/21/2006
Water/DWV Preotection Against Physical Damage (IRC) 1- PIPING WITHIN 1-1/2" OF NAILING SURFACE TO BE PROTECTED WITH NAIL GUARDS. (INCLUDING PIPING IMMEDIATELY ADJACENT TO STUD) 2- COPPER WATER PIPING MAY NOT BE IN CONTACT WITH DISSIMILAR METAL. Restroom
Correction
Corrective Action Required
02/21/2006
None DO NOT INSULATE DO NOT ROCK
All Rough Inspection - Commercial Partial 02/23/2006
Correction
Partial Correction
02/23/2006
BOXES INCOMPLETE
Correction
Resolved
02/23/2006
Water/DWV Preotection Against Physical Damage (IRC) Restroom
Correction
Resolved
02/23/2006
None
Correction
Corrective Action Required
02/23/2006
Roof Extension (Plumbing Vent) IPC COMPLETE PLUMBING VENT THROUGHN THE ROOF.
Correction
Corrective Action Required
02/23/2006
Bathroom ventilation (IRC) COMPLETE EXHAUST FOR BATHROOMS.
Correction
Resolved
02/23/2006
None OK TO ROCK WALLS ONLY
Correction
Partial Correction
02/23/2006
None WALLS ONLY APPROVED
Above Ceiling Inspection Failed 03/13/2006
Correction
Corrective Action Required
03/13/2006
ELELCTRICAL BOXS 2 J-BOXS REQUIRES - PLUGS
All Rough Inspection - Commercial Passed 03/22/2006
Correction
Resolved
03/22/2006
BOXES INCOMPLETE
Correction
Resolved
03/22/2006
Roof Extension (Plumbing Vent) IPC
Correction
Resolved
03/22/2006
Bathroom ventilation (IRC)
Correction
Resolved
03/22/2006
None
Above Ceiling Inspection Passed 03/22/2006
Correction
Resolved
03/22/2006
ELELCTRICAL BOXS
Occupancy Inspection - Codes Commercial Failed 03/22/2006
Correction
Corrective Action Required
03/22/2006
FIRE DEPT. REQUIREMENTS 1 - 5 # FIRE EXTINGUISHER REQUIRED.
Occupancy Inspection - Codes Commercial Passed 10/12/2006
Correction
Resolved
10/12/2006
FIRE DEPT. REQUIREMENTS
Correction
Resolved
10/12/2006
None OCCUPANCY APPROVED CLOSE PERMIT
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home