Permit Application Status

B0502162


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0502162
Building Permit - Commercial
Certificate of Occupancy
GOLF AMERICA LLC
ALTERATION COMMERCIAL
CHAPEL RIDGE CLUBHOUSE RENOVATION
11/29/2005
12/21/2005
06/19/2006
10/02/2006
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES, Address:839 NE WOODS CHAPEL RD  
DAVIDSON DESIGN GROUP, Address:11301STRANG LINE ROAD  
GOLF AMERICA LLC, Address:3215 NE CARNEGIE DR STE 200  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 06/17/2006 10/29/2010
Correction

Codes Administration - The floor/ceiling assembly in this building is a rated fire-resistant assembly. The plans do not indicate how the new penetrations will be protected and how the openings left by the removal of systems will be protected.
Correction

Codes Administration - For the Health Department permit approval contact Steve Hutchens with the Jackson County Public Works Department at 816-881-4471. Approval is required by the City of Lee's Summit prior to issuance of any type of permit.
Correction

Codes Administration - The calculated occupant load is not provided.
Correction

Codes Administration - The Project Synopsis on Sheet A2.1 indicates and occupancy type of A3 but the banquet facilities are actually A2 occupancies.
Correction

Codes Administration - The Project Synopsis on Sheet A2.1 indicates tha the building is not sprinkled.
Correction

Fire Department- The occupant load shall be posted in a conspicuous location near the main door to the banquet room.
Correction

Fire Department- What is the planned use of the basement? Existing fire resistant features and protection shall be maintained until the storage and use of the golf carts is no longer being done.
Correction

Codes Administration - 2003 IBC 1110.1 - Signs. Required accessible elements shall be identified by the International Symbol of Accessiblity a the following locations: 1. Accessible parking spaces required by Section 1106.1 except where the total number of parking spaces provided is four or less. 2. Accessible passenger loading zones. 3. Accessbile areas of refuge required by Section 1007.6. 4. Accessible rooms where multiple single-user toilet or bathing rooms are clustered in a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the checkout aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting and locker rooms where not all such rooms are accessible.
Correction

Codes Administration - 2003 IBC 1004.3 - Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Codes Administration - For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

Codes Administration - For the Health Department permit approval contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Plan approval is required by the City of Lee's Summit prior to issuance of any type of permit.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm-initiating and notification appli- ances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing informa- tion for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IPC 403.1 - Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. Types of occupancies not shown in Tale 403.1 shall be considered individually by the code official. The number of occupants shall be deetermined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $329.90 $329.90 Paid 12/21/2005
89 Sewer Tap Fees $90.00 $90.00 Paid 12/21/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rated Assembly Inspection Failed 01/13/2006
Correction
Corrective Action Required
01/13/2006
TEXT SCREW PATTERN TO BE 8" O.C. IN VALLEYS, 12" IN FIELDS. OK TO COVER BOTH SIDES OF WALLS. DO NOT TAPE.
All Rough Inspection - Commercial Passed 01/13/2006
Correction
Resolved
01/13/2006
None OK TO COVER FIRST FLOOR WALLS.
Rated Assembly Inspection Passed 01/17/2006
Correction
Resolved
01/17/2006
TEXT
Above Ceiling Inspection Partial 01/23/2006
Correction
Partial Correction
01/23/2006
None APPROVED TO COVER CEILING IN FRONT OF KITCHEN PASS-THRU WINDOW.
Above Ceiling Inspection Partial 02/10/2006
Correction
Partial Correction
02/10/2006
None APPROVED TO COVER: ALL OF UPPER FLOOR CONTINGENT UPON COVERING & SECURING ALL JUNCTION BOXES & SUPPORTING VENT PIPE ABOVE MEN'S RESTROOM & COMPLETING CONDUIT TO NORTH EXIT LIGHT.
Above Ceiling Inspection Passed 03/01/2006
Correction
Resolved
03/01/2006
None
Occupancy Inspection - Codes Commercial Failed 03/01/2006
Correction
Resolved
03/01/2006
30 DAY TCO
Correction
Corrective Action Required
03/01/2006
Panel Circuit Identification (IRC) 1- PANEL SHALL BE LABELED TO MATCH BREAKER. (BREAKER MUST ALSO BE LABELED) 2- COVER BLANKS 3- COVER PLATE IS UPSIDE DOWN. NUMBERS TO BE DESCENDING. STORAGE ROOM
Correction
Corrective Action Required
03/01/2006
ICE BASIN DRAINAGE INSTALL DRAINAGE SYSTEM FOR ICE BASIN/SODA MACHINE FOR INSPECTION Bar COUNTER
Correction
Corrective Action Required
03/01/2006
POST MAX. OCCUPANCY SIGNAGE
Correction
Corrective Action Required
03/01/2006
COMBUSTION AIR COMBUSTION AIR INTAKE/OUTLETS REQUIRED. SUBMIT PLANS TO CODES DEPARTMENT AND FIRE DEPARTMENT APPROVAL. PLANS TO INCLUDE THE FOLLOWING ISSUES: 1- REQ'D SIZE/LOCATION 2- FANS IN ADJACENT SPACE 3- FIRE RATING 4- HAZARD LEVEL OF ADJACENT SPACE. BASEMENT FURN. ROOM
Correction
Corrective Action Required
03/01/2006
HEALTH DEPARTMENT KITCHEN SHALL NOT BE USED UNTIL APPROVED BY JACKSON COUNTY HEALTH DEPARTMENT. FINAL OCCUPANCY SHALL NOT BE GRANTED UNTIL VERIFICATION OF APPROVAL IS SUBMITTED TO CODES DEPARTMENT UNDER SEPARATE COVER
Correction
Partial Correction
03/01/2006
Receive Fire Department approval APPROVED FOR TEMPORARY BY CAPTAIN DIRR UNDER SEPARATE COVER
Occupancy Inspection - Codes Commercial Failed 04/21/2006
Correction
Resolved
04/21/2006
Receive Fire Department approval APPROVED BY CAPTAIN DIRR
Correction
Resolved
04/21/2006
HEALTH DEPARTMENT
Correction
Partial Correction
04/21/2006
COMBUSTION AIR COMBUSTION AIR INTAKE/OUTLETS REQUIRED. SUBMIT PLANS TO CODES DEPARTMENT AND FIRE DEPARTMENT APPROVAL. PLANS TO INCLUDE THE FOLLOWING ISSUES: 1- REQ'D SIZE/LOCATION 2- FANS IN ADJACENT SPACE 3- FIRE RATING 4- HAZARD LEVEL OF ADJACENT SPACE. BASEMENT FURN. ROOM
Correction
Resolved
04/21/2006
POST MAX. OCCUPANCY SIGNAGE
Correction
Resolved
04/21/2006
ICE BASIN DRAINAGE
Correction
Resolved
04/21/2006
Panel Circuit Identification (IRC)
Correction
Resolved
04/21/2006
30 DAY TCO TCO EXTENDED TO SEPTEMBER 30, 2006
Correction
Partial Correction
04/21/2006
COMBUSTION AIR COMBUSTION AIR ISSUES DEFFERED UNTIL SEPTEMBER 30 BASEMENT FURN. ROOM
Occupancy Inspection - Codes Commercial Passed 09/29/2006
Correction
Resolved
09/29/2006
COMBUSTION AIR
Correction
Resolved
09/29/2006
COMBUSTION AIR
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home