Summary
B0502073
Building Permit - Commercial
Final Completion
THE NORTHWESTERN MUTUAL LIFE INS CO
NEW COMMERCIAL
MAINTENANCE/CAR CARE/TRASH COMPACTOR
11/17/2005
10/17/2006
04/15/2007
10/22/2007
Locations
Contacts
AMLI RESIDENTIAL CONSTRUCTION LLC, Address:10800 FARLEY SUITE 304  
CLIFFORD WONG, Address:5757 ALPHA RD SUITE 505  
STANDARD SHEET METAL INC, Address:405 N OLIVE ST  
SANTA FE TRAILS PLUMBING, INC., Address:PO BOX 860511  
MTD ELECTRIC, Address:20581 SYCAMORE DR  
THE NORTHWESTERN MUTUAL LIFE INS CO, Address:PO BOX 3151  
JVM NEW LONGVIEW LLC, Address:PO BOX 06494  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/06/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1103.1 - Where required. Buildings and structures, temporary or permanent, includeing their associated sites and facilities, shall be accessible to persons with physical disablilities.
Correction

Codes Administration - This permit is for the maintenance/car care facility and the trash compactor facility.
Correction

Codes Administration - The plans indicate that there is a floor drain located in the car care area but I am unable to locate any additional information regarding the associated plumbing and interceptor.
Correction

Codes Administration - The plans indicate a drain in the trash compactor but I am unable to locate any additional information regarding the plumbing and interceptor.
Correction

Codes Administration - I am unable to locate the specifications for the installation of the mechanical, electrical and plumbing.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $225.04 $225.04 Paid 10/17/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Passed 09/01/2006
Correction
Resolved
09/01/2006
None APPROVED PER PLANS
All Rough Inspection - Commercial Failed 04/17/2007
Correction
Corrective Action Required
04/17/2007
Flashings and Sealing (IRC) VENT FLASHING REQUIRED ROOF
Correction
Corrective Action Required
04/17/2007
PANEL COVER INSTALL PANEL COVER
Correction
Corrective Action Required
04/17/2007
CEILING LIGHTS NOT INSTALLED
Correction
Corrective Action Required
04/17/2007
Piping Support (IRC) SUPPORT VENT PIPE IN THE ATTIC. OK INSULATION Attic Area
Correction
Corrective Action Required
04/17/2007
POWER FOR COMPACTOR NO ELECTRIC RAN TO THE COMPACTOR AT TIME OF INSPECTION.
Electrical Service Inspection Failed 04/17/2007
Correction
Corrective Action Required
04/17/2007
Grounding Electrode Installation (IRC) NO GROUND INSTALLED FOR SERVICE PANEL
All Rough Inspection - Commercial Failed 04/18/2007
Correction
Resolved
04/18/2007
None OK TO ROCK WALLS AND CEILING
Erosion Control Inspection Residential Passed 04/18/2007
All Rough Inspection - Commercial Failed 06/01/2007
Correction
Resolved
06/01/2007
Flashings and Sealing (IRC) ROOF
Correction
Corrective Action Required
06/01/2007
PANEL COVER INSTALL PANEL COVER
Correction
Resolved
06/01/2007
CEILING LIGHTS NOT INSTALLED
Correction
Resolved
06/01/2007
Piping Support (IRC) Attic Area
Correction
Corrective Action Required
06/01/2007
POWER FOR COMPACTOR NO ELECTRIC RAN TO THE COMPACTOR AT TIME OF INSPECTION.
Electrical Service Inspection Failed 06/01/2007
Correction
Resolved
06/01/2007
Grounding Electrode Installation (IRC)
Correction
Corrective Action Required
06/01/2007
WIRE SIZE 4/ 0 ALUMINUM SERVICE CONDUCTOR REQUIRED FOR THE 200 AMP SERVICE.
Erosion Control Inspection Residential Passed 06/01/2007
All Rough Inspection - Commercial Passed 06/05/2007
Correction
Resolved
06/05/2007
PANEL COVER INSTALL PANEL COVER
Correction
Resolved
06/05/2007
POWER FOR COMPACTOR
Electrical Service Inspection Passed 06/05/2007
Correction
Resolved
06/05/2007
WIRE SIZE 200 AMP SERVICE APPROVED - RELEASE
Occupancy Inspection - Codes Commercial Failed 07/18/2007
Correction
Resolved
07/18/2007
Disconnecting Means (Appliance Installation) EXTERIOR
Correction
Corrective Action Required
07/18/2007
SPLASH BLOCKS SPLASH BLOCKS REQUIRED.
Correction
Corrective Action Required
07/18/2007
ADDRESS INSTALL ADDRESS NUMBERS VISIBLE FROM TOWER PARK DR.
Correction
Corrective Action Required
07/18/2007
Receive Fire Department approval 1 FIRE EXTINGUISHER REQUIRED
Correction
Corrective Action Required
07/18/2007
Handrails (IRC) HANDRAILS REQUIRED ON BOTH SIDES OF STAIRS. STRAIS AT TRASH COMPACTOR
Correction
Corrective Action Required
07/18/2007
MOP SINK FAUCET INSTALL AIREATOR OR A BACKFLOW DEVICE ON MOP SINK FAUCET.
Erosion Control Inspection Residential Passed 07/18/2007
Occupancy Inspection - Codes Commercial Failed 10/01/2007
Correction
Resolved
10/01/2007
SPLASH BLOCKS
Correction
Resolved
10/01/2007
ADDRESS
Correction
Resolved
10/01/2007
Receive Fire Department approval
Correction
Resolved
10/01/2007
Handrails (IRC) STRAIS AT TRASH COMPACTOR
Correction
Resolved
10/01/2007
MOP SINK FAUCET
Correction
Corrective Action Required
10/01/2007
Receive Planning & Development Approval
Correction
Corrective Action Required
10/01/2007
Receive Public Works Approval
Occupancy Inspection - Codes Commercial Passed 10/19/2007
Correction
Resolved
10/19/2007
Receive Planning & Development Approval
Correction
Resolved
10/19/2007
Receive Public Works Approval
Erosion Control Inspection Residential Passed 10/19/2007
Final Inspection - Commercial Passed 10/19/2007
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home