Summary
B0502072
Building Permit - Commercial
Certificate of Occupancy
THE NORTHWESTERN MUTUAL LIFE INS CO
NEW COMMERCIAL
LEASING OFFICE/POOL/MAIL KIOS
11/17/2005
06/30/2006
12/27/2006
05/02/2008
Locations
Contacts
AMLI RESIDENTIAL CONSTRUCTION LLC, Address:10800 FARLEY SUITE 304  
CLIFFORD WONG, Address:5757 ALPHA RD SUITE 505  
THE NORTHWESTERN MUTUAL LIFE INS CO, Address:PO BOX 3151  
JVM NEW LONGVIEW LLC, Address:PO BOX 06494  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/06/2006 10/29/2010
Correction

Codes Administration - ANSI A117.1-1998 804.7.6 - Refrigerator/Freezer. Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches maximum above the floor or ground. The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches maximum from the centerline of the dedicated space.
Correction

Codes Administration - 2003 IBC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be proivided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Exit access corridors, passageways and aisles in rooms and spaces which require two or more means of egress. 2. Exit access corridors and exit stairways locate in buildings required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1023.1, in buildings required to have two or more exits. 5. The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702.
Correction

Codes Administration - 2003 IBC 1010.8 - Handrails. Ramps with a rise greater than 6 inches (152 mm) shall have handrails on both sides complying with Section 1009.11.
Correction

Codes Administration - LSCO 7-1012 - Steps or ladders. Two (2) or more means of egress in the form of steps or ladders shall be provided for all swimming pools. At least one (1) such means of egress shall be located on a side of the pool at both the deep end and shallow end of the pool. Treads of steps and ladders shall be constructed of nonslip material and at least three (3) inches wide for their full length. Steps and ladders shall have a handrail on both sides.
Correction

Codes Administration - LSCO 7-1015 B - Swimming pools shall be equipped with facilities for completely emptying the pool and the discharge of the pool water to the sewer shall be at a rate not exceeding two hundred (200) gallons per minute. No direct connection shall be made to the sewer.
Correction

Codes Administration - The general information for the structural drawings indicates that the plans are designed to the requirements of the 2000 IBC. The 2003 IBC is currently adopted by the City of Lee's Summit.
Correction

Codes Administration - I am unable to locate the specifications for the installation of the mechanical, electrical and plumbing.
Correction

Codes Administration - This permit covers the construction of the clubhouse/leasing office, pool, pool area and mail kios.
Correction

Codes Administration - The plans do not include information regarding pool equipment.
Correction

Codes Administration - 2003 IBC 1009.4 - Stairway landings. There shall be a floor or landing at the top and botton of each stairway. The width of landings shall not be less than the width of sairways they serve. Every landing shall have a minimum dimension measured in the direction of travel equal to the width of the stairway. Such dimension need not excee 48 inches where the stairway has a straight run.
Correction

Fire Department- Provide information on the pool equipment. The pump room shall be appropriately marked for the materials within (NFPA 704).
Correction

Fire Department- 1004.3 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter 7, Section 7-1018 - Every swimming pool shall be equipped with one (1) or more throwing ring buoys not more than fifteen (15) inches in diameter and having sixty (60) feet of three-sixteenths-inch manila line attached, and one (1) or more light but strong poles with blunt ends and not less than twelve (12) feet in length, for making reach assists or rescues.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $1,035.71 $1,035.71 Paid 06/30/2006
89 Sewer Tap Fees $240.00 $240.00 Paid 06/30/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Passed 07/07/2006
Sewer Service Inspection Passed 07/07/2006
Erosion Control Inspection Residential Passed 10/26/2006
All Rough Inspection - Commercial Failed 10/26/2006
Correction
Corrective Action Required
10/26/2006
WINDOWS / DOORS WINDOWS AND DOORS NOT INSTALLED
Correction
Corrective Action Required
10/26/2006
Appliance Access For Service, Repair, Replacement (IRC) ATTIC FURNACES WILL BE INSPECTED WHEN ACCESS IS INSTALLED TO UNITS. [CHECK FLOAT SWITCHS] OK INSULATION AND ROCK AFTER WINDOWS AND DOORS ARE INSTALLED. Attic Area
Electrical Service Inspection Passed 11/29/2006
Correction
Resolved
11/29/2006
None ELECT. SERVICE APPROVED. 400 AMP SERVICE. P-1 APPROVED P-2 APPROVED RELEASE ELECT.
Erosion Control Inspection Residential Passed 11/29/2006
Pool Steel/Bonding - Commercial Partial 12/20/2006
Correction
Partial Correction
12/20/2006
None POLL LIGHT BONDING ONLY APPROVED.
Pool Steel/Bonding - Commercial Partial 12/21/2006
Correction
Partial Correction
12/21/2006
None POOL SHELL AND HAND RAILS FOR STEPS
All Rough Inspection - Commercial Passed 02/16/2007
Correction
Resolved
02/16/2007
WINDOWS / DOORS
Correction
Resolved
02/16/2007
Appliance Access For Service, Repair, Replacement (IRC) Attic Area
Occupancy Inspection - Codes Commercial Failed 02/16/2007
Correction
Corrective Action Required
02/16/2007
Outlet Box Covers & Faceplates (IRC) TERMINATE ALL EXTERIOR CONDUCTORS IN J-BOXS AS REQUIRED PER N. E. C. EXTERIOR
Correction
Corrective Action Required
02/16/2007
Receive Planning & Development Approval
Correction
Corrective Action Required
02/16/2007
Receive Public Works Approval
Correction
Corrective Action Required
02/16/2007
EGRESS 1. REMOVE TARPS COVERING ENTRY. EXTERIOR
Correction
Corrective Action Required
02/16/2007
System Service Ground (IRC) WATER LINE GROUND REQUIRED TO BE ACCESSIBLE. POOL ROOM
Correction
Corrective Action Required
02/16/2007
GRAB BARS GRAB BARS NOT INSTALLED. Bathroom
Correction
Corrective Action Required
02/16/2007
AC UNIT AC UNIT NOT NOT INSTALLED
Correction
Corrective Action Required
02/16/2007
EXTERIOR BRICK COMPLETE EXTERIOR BRICK BELOW WINDOWS. EXTERIOR
Correction
Corrective Action Required
02/16/2007
WATER OBTAIN WATER DEPARTMENT APPROVAL ON BACKFLOW DEVICE.
Erosion Control Inspection Residential Passed 02/16/2007
Occupancy Inspection - Codes Commercial Failed 02/20/2007
Correction
Resolved
02/20/2007
Outlet Box Covers & Faceplates (IRC) EXTERIOR
Correction
Resolved
02/20/2007
EGRESS EXTERIOR
Correction
Resolved
02/20/2007
System Service Ground (IRC) POOL ROOM
Correction
Resolved
02/20/2007
GRAB BARS Bathroom
Correction
Corrective Action Required
02/20/2007
WATER OBTAIN WATER DEPARTMENT APPROVAL ON BACKFLOW DEVICE.
Erosion Control Inspection Residential Passed 02/20/2007
Pool Steel/Bonding - Commercial Partial 03/27/2007
Correction
Partial Correction
03/27/2007
None POOL SHELL AND HAND RAILS FOR STEPS
Correction
Corrective Action Required
03/27/2007
NOT READY
Pool Steel/Bonding - Commercial Partial 03/28/2007
Correction
Partial Correction
03/28/2007
None POOL SHELL AND HAND RAILS FOR STEPS
Correction
Partial Correction
03/28/2007
NOT READY
Correction
Partial Correction
03/28/2007
None POOL DECK BONDING APPROVED
Pool Steel/Bonding - Commercial Partial 04/17/2007
Correction
Partial Correction
04/17/2007
None POOL SHELL AND HAND RAILS FOR STEPS
Correction
Partial Correction
04/17/2007
NOT READY
Correction
Partial Correction
04/17/2007
None POOL LIGHTS BONDING APPROVED
Occupancy Inspection - Codes Commercial Failed 05/21/2007
Correction
Resolved
05/21/2007
AC UNIT
Correction
Resolved
05/21/2007
EXTERIOR BRICK EXTERIOR
Correction
Corrective Action Required
05/21/2007
WATER OBTAIN WATER DEPARTMENT APPROVAL ON BACKFLOW DEVICE.
Pool Steel/Bonding - Commercial Passed 05/21/2007
Correction
Resolved
05/21/2007
None
Correction
Resolved
05/21/2007
NOT READY
Correction
Resolved
05/21/2007
None
Pool Final - Commercial Failed 05/21/2007
Correction
Corrective Action Required
05/21/2007
LABEL SERVICE PANEL LABEL SERVICE PANEL. POOL EQUIPMENT ROOM
Correction
Corrective Action Required
05/21/2007
GFCI OUTLETS IN POOL EQUIPMENT ROOM REQUIRED TO BE GFCI EQUIPMENT ROOM
Correction
Corrective Action Required
05/21/2007
BACKFLOW TEST PROVIDE BACKFLOW TEST RESULTS ON BUILDING WATER SUPPLY.
Pool Final - Commercial Failed 07/10/2007
Correction
Resolved
07/10/2007
LABEL SERVICE PANEL POOL EQUIPMENT ROOM
Correction
Resolved
07/10/2007
GFCI EQUIPMENT ROOM
Occupancy Inspection - Codes Commercial Failed 07/10/2007
Occupancy Inspection - Codes Commercial Passed 04/30/2008
Correction
Resolved
04/30/2008
Receive Planning & Development Approval
Correction
Resolved
04/30/2008
Receive Public Works Approval
Correction
Resolved
04/30/2008
WATER
Correction
Resolved
04/30/2008
None OCCUPANCY APPROVED CLOSE PERMIT C.O.
Pool Final - Commercial Passed 05/01/2008
Correction
Resolved
05/01/2008
BACKFLOW TEST PROVIDE BACKFLOW TEST RESULTS ON BUILDING WATER SUPPLY.
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home