Permit Application Status

B0501958


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0501958
Building Permit - Commercial
Certificate of Occupancy
TI SUMMIT CREST PLAZA LLC
CHANGE OF TENANT
TENANT FINISH BAR/LOUNGE
10/28/2005
11/22/2005
05/21/2006
01/30/2006
Locations
Contacts
JOHN ADAMS, Address:3512 SW MARKET ST  
TI SUMMIT CREST PLAZA LLC, Address:7611 STATE LINE RD STE 301  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/29/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1004.1 - Design occupant load. In determining means of egress requirements, the number of occupants for whom meansof egress facilities shall be provided shall be established by the largest number computed in accordance with Sections 1004.1.1 through 1004.1.3.
Correction

Codes Administration - 2003 IBC 1004.3 - Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

Codes Administration - 2003 IBC 1110.1 - Signs. Required accessible elements shall be identified by the International Symbol of Accessiblity a the following locations: 1. Accessible parking spaces required by Section 1106.1 except where the total number of parking spaces provided is four or less. 2. Accessible passenger loading zones. 3. Accessbile areas of refuge required by Section 1007.6. 4. Accessible rooms where multiple single-user toilet or bathing rooms are clustered in a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the checkout aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting and locker rooms where not all such rooms are accessible.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm notification appliances.
Correction

Fire Department-IFC 1004.3 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

Codes Administration - 2003 IBC 1005.1 - Minimum required egress width. The means of egress width shall not be less than required by this section. The total width of means of egress in inches shall not be les than the total occupant load served by the means of egress multiplied by the factors in Table 1005.1 and not less than specified elsewhere in this code. Multipule means of egress shall be sized such that the loss of any one means of egress shall not reduce the available capacity to less than 50 percent of the required capacity. The maximum capacity required from any story of a building shall be maintained to the termination of the means of egress.
Correction

Codes Administration - For the Health Department permit approval contact Steve Hutchens with the Jackson County Public Works Department at 816-881-4471. Permit approval is required by the City of Lee's Summit prior to issuance of any type of building permit.
Correction

Codes Administration - The location of the condensing unit for the cooler is not indicated on the plans.
Correction

Codes Administration - Information on the plumbing system has not been provided.
Correction

Codes Administration - 2003-IMC 303.3 Prohibited locations. Fuel-fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: 1. Sleeping rooms. 2. Bathrooms. 3. Toilet rooms. 4. Storage closets. 5. Surgical rooms.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Codes Administration - For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

Codes Administration - For the Health Department permit approval contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Plan approval is required by the City of Lee's Summit prior to issuance of any type of permit.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IMC 306.2 - Appliances in rooms. Rooms containing appliances requiring access shall be provided with a door and an unobstructed passageway measuring not less than 36 inches (914 mm) wide and 80 inches (2032 mm) high.
Correction

Codes Administration - 2003 IMC 403.3 - Ventilation rate. Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and occupant load or other parameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less than the number determined fron the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall b designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

Codes Administration - 2003 IPC 608.3 - Devices, appurtenances, appliances and apparatus. All devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that connect to the water supply system, shall be provided with protection against backflow and contamination of the water supply system. Water pumps, filters, softners, tanks and all other appliances and devices that handle or treat potable water shall be protected against contamination.
Correction

Codes Administration - 2003 IPC 802.1.1 - Food handling. Equipment and fixtures utilized for the storage, preparation and handling of food shall discharge through an indirect waste pipe by means of an air gap.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Lee's Summit Code of Ordinances, Section 17-6.D - Regulated smoking environments classified. No persons with ownership, management, or control of a food service establishment shall operate such establishment unless there is posted signage at a height and location conspicuous to persons entering the establishment, eith primary lettering of not less than one inch in height according to one of the following classifications of food service establishments: 1. Smoke-free establishment (existing and new establishments) 2. Smoking establishment (existing establishments only) 3. Mixed smoking/non-smoking establishment (existing establishments only) 4. Smoking restricted establishment (existing and new establishments)
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $81.70 $81.70 Paid 11/22/2005
89 Sewer Tap Fees $150.00 $150.00 Paid 11/22/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Failed 12/08/2005
Correction
Resolved
12/08/2005
INSPECTION DENIED
Correction
Corrective Action Required
12/08/2005
NO ACCESS FOR INSPECTION -ARRIVED AT 1:45 PM FOR REINSPECTION BUT DOOR IS LOCKED
All Rough Inspection - Commercial Failed 12/09/2005
Correction
Resolved
12/09/2005
NO ACCESS FOR INSPECTION
Correction
Corrective Action Required
12/09/2005
UNDERGROUND PLUMBING NOT BEEN INSPECTED AND APPROVED UNDER THIS OPERMIT. WILL RESEARCH THIS AND VERIFY THAT UNDERSLAB PLUMBING HAS BEEN APPROVED
Correction
Corrective Action Required
12/09/2005
TEXT -ABOVE CEILING NOT INSPECTED. ALL TRADES NOT COMPLETED ABOVE CEILING -DO NOT COVER CORNER BATH 1 HR WALL. NOTE: SERVICE GROUNDING CONNECTION AT WALL. WILL REQUIRE ACCESS
Correction
Resolved
12/09/2005
BATHS AND MAIN AREA WALLS ONLY BATH WALL ROUGH APPROVED, EXCEPT FOR CORNER BATH FIRE WALL NOTE: BATHFAN DUCT TO OUTSIDE NOT COMPLETED
All Rough Inspection - Commercial Failed 12/13/2005
Correction
Corrective Action Required
12/13/2005
UNDERGROUND PLUMBING NOT BEEN INSPECTED AND APPROVED UNDER THIS OPERMIT. WILL RESEARCH THIS AND VERIFY THAT UNDERSLAB PLUMBING HAS BEEN APPROVED PROVIDE SIGNED LETTER FROM PLUMBER STATING UNDERSLAB PLUMBING MEETS CODE REQUIREMENT
Correction
Corrective Action Required
12/13/2005
TEXT -ABOVE CEILING NOT INSPECTED. ALL TRADES NOT COMPLETED ABOVE CEILING -NOTE: SERVICE GROUNDING CONNECTION AT WALL. WILL REQUIRE ACCESS OK TO SHEETROCK REAR BATH CORNER WALL
Correction
Resolved
12/13/2005
BATHS AND MAIN AREA WALLS ONLY BATH WALL ROUGH APPROVED NOTE: BATHFAN DUCT TO OUTSIDE NOT COMPLETED
All Rough Inspection - Commercial Failed 01/17/2006
Correction
Corrective Action Required
01/17/2006
UNDERGROUND PLUMBING NOT BEEN INSPECTED AND APPROVED UNDER THIS OPERMIT. WILL RESEARCH THIS AND VERIFY THAT UNDERSLAB PLUMBING HAS BEEN APPROVED PROVIDE SIGNED LETTER FROM PLUMBER STATING UNDERSLAB PLUMBING MEETS CODE REQUIREMENT
Correction
Corrective Action Required
01/17/2006
TEXT -ABOVE CEILING INSPECTED -NOTE: SERVICE GROUNDING CONNECTION AT WALL. WILL REQUIRE ACCESS
Occupancy Inspection - Codes Commercial Failed 01/17/2006
Correction
Corrective Action Required
01/17/2006
PLUMBER BUSINESS LICENSE PROVIDE PLUMBER BUSINESS LICENSE BEFORE ANY OCCUPANCY CAN BE APPROVED
Correction
Corrective Action Required
01/17/2006
ALLROUGH DEFICIENCIES
Correction
Corrective Action Required
01/17/2006
INSTALL BATH ROOM HANDICAP SIGNS
Correction
Corrective Action Required
01/17/2006
BATHROOM SIDE GRAB BARS SHALL BE 42" LONG GRAB BARS INSTALLATION INCOMPLETE
Correction
Corrective Action Required
01/17/2006
PROVIDE COVER PLATES FOR OPEN ELECTRICAL BOXES -IN BATH ROOMS, MECHANICAL ROOM SWITCH, OPEN BOX ABOVE WOMAN BATH SINK
Correction
Corrective Action Required
01/17/2006
CUT OUT ALL WALL COVERING EXPOSED WITHIN ELECTRICAL BOXES
Correction
Corrective Action Required
01/17/2006
INSTALL BATHFAN AT MEN RESTROOM
Correction
Resolved
01/17/2006
Receive Fire Department approval OCCUPANT LOAD SIGN INSTALLED
Correction
Corrective Action Required
01/17/2006
PROVIDE A/C BREAKER SIZE PER LABEL MAX IS 35 AMP. 40 AMP BREAKER INSTALLED
Correction
Corrective Action Required
01/17/2006
INSTALL 15 AMP BREAKER FOR AIR HANDLING UNIT PER LABEL 20 AMP INSTALLED
Correction
Corrective Action Required
01/17/2006
INSTALL SPARK RINGS FOR ALL ELECTRICAL BOXES ALONG WALL WHERE COMBUSTIBLE (WOOD COVERING) IS EXPOSED INSIDE BOXES
Correction
Corrective Action Required
01/17/2006
SUPPORT FLEXIBLE AIR DUCTS EVERY 5 FT IN CEILING SPACE
Occupancy Inspection - Codes Commercial Failed 01/20/2006
Correction
Corrective Action Required
01/20/2006
ALLROUGH DEFICIENCIES -PROVIDE SIGNED LETTER FROM PLUMBER ABOUT UNDERGROUND PLUMBING BEING INSTALLED PER CODE.
Correction
Resolved
01/20/2006
INSTALL BATH ROOM HANDICAP SIGNS
Correction
Resolved
01/20/2006
BATHROOM SIDE GRAB BARS SHALL BE 42" LONG
Correction
Resolved
01/20/2006
PROVIDE COVER PLATES FOR OPEN ELECTRICAL BOXES
Correction
Resolved
01/20/2006
CUT OUT ALL WALL COVERING EXPOSED WITHIN ELECTRICAL BOXES
Correction
Resolved
01/20/2006
INSTALL BATHFAN AT MEN RESTROOM
Correction
Resolved
01/20/2006
PROVIDE A/C BREAKER SIZE PER LABEL
Correction
Resolved
01/20/2006
INSTALL 15 AMP BREAKER FOR AIR HANDLING UNIT PER LABEL
Correction
Resolved
01/20/2006
INSTALL SPARK RINGS FOR ALL ELECTRICAL BOXES ALONG WALL
Correction
Resolved
01/20/2006
SUPPORT FLEXIBLE AIR DUCTS EVERY 5 FT
Occupancy Inspection - Codes Commercial Failed 01/25/2006
Correction
Resolved
01/25/2006
ALLROUGH DEFICIENCIES
All Rough Inspection - Commercial Passed 01/30/2006
Correction
Resolved
01/30/2006
UNDERGROUND PLUMBING NOT BEEN INSPECTED AND APPROVED
Correction
Resolved
01/30/2006
TEXT
Occupancy Inspection - Codes Commercial Passed 01/30/2006
Correction
Resolved
01/30/2006
PLUMBER BUSINESS LICENSE
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home