Summary
B0501750
Building Permit - Commercial
Certificate of Occupancy
RMT INVESTMENTS INC
CHANGE OF TENANT
TENANT FINISH
09/29/2005
10/25/2005
04/23/2006
12/27/2005
Locations
Contacts
KURZWEIL COUNTRY MEATS, Address:403 SW WARD RD  
RMT INVESTMENTS INC, Address:8951 S 126TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 03/28/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1013.2 - Egress through intervening spaces. Egress from a room or space shall not pass through adjoining or intervening rooms or areas, except where such adjoining rooms or areas are accessory to the area served; are not a high-hazard occupancy and provide a discernible path of egress travel to an exit. Egress shall not pass through kitchens, storage rooms, closets or spaces used for similar purposes. An exit access shall not pass through a room that can be locked to prevent egress. Means of egress from dwelling units or sleeping areas shall not lead through other sleeping areas, toilet roons or bathrooms.
Correction

Fire Department;-Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Codes Administration - For the Health Department approval contact Steve Hutchens with the Jackson County Public Works Department at 816-881-4471. Permit approval is required by the City of Lee's Summit prior to issuance of the full building permit.
Correction

Codes Administration - The project cost has not been provided.
Correction

Codes Administration - Specification have not been provided for the electrical system.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Codes Administration - For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IPC 608.16.1 - Beverage dispensers. The water supply connection to carbonated beverage dispensers shall be protected against backflow by a backflow preventer conforming to ASSE 1022 or by an air gap. The backflow preventer device and the piping downstream therefrom shall not be affected by carbon dioxide gas.
Correction

Codes Administration - 2003 IPC 608.3 - Devices, appurtenances, appliances and apparatus. All devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that connect to the water supply system, shall be provided with protection against backflow and contamination of the water supply system. Water pumps, filters, softners, tanks and all other appliances and devices that handle or treat potable water shall be protected against contamination.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $137.00 $137.00 Paid 10/25/2005
24 BLDG Plan Check Fees $13.25 $13.25 Paid 10/25/2005
25 Electrical Permit Fee $95.38 $95.38 Paid 10/25/2005
25 Mechanical Permit Fees $34.50 $34.50 Paid 10/25/2005
25 Plumbing Permit Fees $29.00 $29.00 Paid 10/25/2005
89 Sewer Tap Fees $150.00 $150.00 Paid 10/25/2005
25 Electrical Permit Fee $20.00 $20.00 Paid 11/09/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Passed 11/03/2005
Correction
Resolved
11/03/2005
None OK TO COVER
Electrical Service Inspection Passed 11/10/2005
Above Ceiling Inspection Passed 11/15/2005
Occupancy Inspection - Codes Commercial Failed 11/15/2005
Correction
Corrective Action Required
11/15/2005
None HAVE OWNER PROVIDE LADDER TO INSPECT CONNECTION OF DUCTWORK - ABOVE CEILING
Occupancy Inspection - Codes Commercial Failed 12/21/2005
Correction
Corrective Action Required
12/21/2005
None HAVE OWNER PROVIDE LADDER TO INSPECT CONNECTION OF DUCTWORK - ABOVE CEILING
Correction
Corrective Action Required
12/21/2005
None CALLED IN FOR INSPECTION AND NO RESPONSE AFTER SECOND VISIT TO LOCATION
Occupancy Inspection - Codes Commercial Passed 12/22/2005
Correction
Resolved
12/22/2005
None HAVE OWNER PROVIDE LADDER TO INSPECT CONNECTION OF DUCTWORK - ABOVE CEILING
Correction
Resolved
12/22/2005
None CALLED IN FOR INSPECTION AND NO RESPONSE AFTER SECOND VISIT TO LOCATION
Correction
Resolved
12/22/2005
Receive Fire Department approval
Correction
Resolved
12/22/2005
Electrical Listing & Labeling (IRC) PERMANENTLY MARK PANEL
Correction
Resolved
12/22/2005
None
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home