Permit Application Status

B0501719


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0501719
Building Permit - Commercial
Certificate of Occupancy
MAZUMA CREDIT UNION
NEW COMMERCIAL
NEW BUILDING
09/21/2005
10/27/2005
04/25/2006
09/02/2008
Locations
Contacts
HBE CORPORATION, Address:11330 OLIVE BOULEVARD  
MAZUMA CREDIT UNION, Address:9300 TROOST AVE  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 04/19/2006 10/29/2010
Correction

Codes Administration - ANSI A117.1-1998 804.7.6 - Refrigerator/Freezer. Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches maximum above the floor or ground. The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches maximum from the centerline of the dedicated space.
Correction

Codes Administration - 2003 IBC 1008.1.1 - Size of doors. The minimum width of each door opening shall be sufficient for the occupant load thereof and shall provide a clear width of not less than 32 inches. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees. Where this section requires a minimum clear width of 32 inches and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches. The maximum width of a swinging door leaf shall be 48 inches nominal. Means of egress doors in an occupancy in Group I-2 used for the movement of beds shall provide a clear width not less than 41.5 inches. The height of doors shall not be less than 80 inches.
Correction

Codes Administration - 2003 IBC 712.3 - Fire-resistance-rated walls. Penetrations into or through fire walls, fire barriers, smoke barrier walls, and fire partitions shall comply with this section.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Codes Administration - Sheet C0.0 indicates that the project is located on Lot 3 at the top of the sheet and on Lot 4 just below that. The project is actually located on Lot 5 of Maple Tree Plaza.
Correction

Codes Administration - I am unable to locate a code analysis for this project.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Codes Administration - All plans submitted for review on or after July 6, 2004 shall be designed to the requirements of the 2003 International Building Code, 2003 International Mechanical Code, 2003 International Plumbing Code, 2003 International Fuel Gas Code, 2003 International Fire Code, 2002 National Electric Code and the ANSI A117.1-1998 as amended and adopted by the City of Lee's Summit.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the code official.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IPC 403.2 - Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex.
Correction

Codes Administration - 2003 IPC 403.6 - Public facilities. Customers, patrons and visitors shall be provided with public toilet facilites in structures and tenant spaces intended for public utilization. Public toilet facilities shall be located not more than one story above or below the space required to be provided with public toilet facilities and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m).
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $4,502.00 $4,502.00 Paid 10/27/2005
24 BLDG Plan Check Fees $95.00 $95.00 Paid 10/27/2005
25 Electrical Permit Fee $232.38 $232.38 Paid 10/27/2005
25 Mechanical Permit Fees $152.00 $152.00 Paid 10/27/2005
25 Plumbing Permit Fees $66.00 $66.00 Paid 10/27/2005
84 Water Meters $200.00 $200.00 Paid 10/27/2005
85 Water Taps $5,468.00 $5,468.00 Paid 10/27/2005
89 Sewer Tap Fees $240.00 $240.00 Paid 10/27/2005
Right of Way Permit $35.00 $35.00 Paid 10/27/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection Failed 11/14/2005
Correction
Corrective Action Required
11/14/2005
COMMENTS TAP AND INITIAL 60' (APPROX.) COVERED PRIOR TO INSPECTION. FROM THAT POINT TO GRADE CLEANOUT APPROVED TO COVER. INITIAL 60' & TAP TO BE UNCOVERED FOR INSPECTION.
Sewer Service Inspection - Commercial Request Complete 11/14/2005 11/14/2005 11/14/2005
Sewer Service Inspection Passed 11/16/2005
Correction
Resolved
11/16/2005
COMMENTS
Sewer Service Inspection - Commercial Request Complete 11/16/2005 11/16/2005 11/16/2005
Water Service Inspection Partial 11/17/2005
Correction
Partial Correction
11/17/2005
WATER SERVICE INSTALLATION WELL FROM CURB APPROVED BY WU & PW; OK TO COVER FROM METER TO MAIN; KINKED LINE EAST OF WELL NOT APPROVED TAP COMPLETED METER WELL SET @ ~15'
Water Service Inspection - Commercial Request Complete 11/17/2005 11/17/2005 11/17/2005
Water Service Inspection Partial 11/18/2005
Correction
Partial Correction
11/18/2005
WATER SERVICE INSTALLATION WELL DISTANCE FROM CURB APPROVED BY WU & PW; OK TO COVER FROM METER TO MAIN + 40' EAST OF METER TAP COMPLETED METER/WELL SET @ ~15'
Water Service Inspection - Commercial Request Complete 11/18/2005 11/18/2005 11/18/2005
Footing Inspection - Commercial Partial 11/23/2005
Correction
Partial Correction
11/23/2005
PERIMETER SPREAD FOOTING & INTEGRAL COLUMN FOOTING PREP PERIMETER EXCEPT FROM (B/8) SW TO (G/8); OK TO POUR WHEN READY COMPONENTS LISTED BELOW:
Correction
Resolved
11/23/2005
INTERIOR ISOLATED COLUMN FOOTINGS
Water Service Inspection Partial 12/02/2005
Correction
Partial Correction
12/02/2005
WATER SERVICE INSTALLATION WELL DISTANCE FROM CURB APPROVED BY WU & PW; OK TO COVER FROM METER TO MAIN + 40' EAST OF METER; TO 138' EAST OF METER; TAP COMPLETED METER/WELL SET @ ~15'
Water Service Inspection - Commercial Request Complete 12/2/2005 12/2/2005 12/02/2005
Water Service Inspection Partial 12/05/2005
Correction
Partial Correction
12/05/2005
WATER SERVICE INSTALLATION WELL DISTANCE FROM CURB APPROVED BY WU & PW; OK TO COVER EXCEPT FROM BUILDING ENTRY TO 5' OUT TAP COMPLETED METER/WELL SET @ ~15'
Water Service Inspection - Commercial Request Complete 12/2/2005 12/5/2005 12/05/2005
Underground Electrical Inspection - Commercial Failed 12/28/2005
Correction
Partial Correction
12/28/2005
EXTERIOR LIGHT POST AND SERVICE ENTRANCE ALL LIGHT POLES APPROVED BUT ONE - AT NE OF BUILDING OPENING SERVICE ENTRANCE PIPING INSTALLED AND APPROVED EXTERIOR OK TO COVER
Underground Electrical Inspection - Commercial Request Complete 12/27/2005 12/28/2005 12/28/2005
Underground Electrical Inspection - Commercial Partial 12/30/2005
Correction
Partial Correction
12/30/2005
EXTERIOR LIGHT POST AND SERVICE ENTRANCE UG CONDUIT SERVING LIGHT POLES APPROVED SERVICE ENTRANCE PIPING INSTALLED AND APPROVED EXTERIOR OK TO COVER
Underground Electrical Inspection - Commercial Request Complete 12/29/2005 12/30/2005 12/30/2005
Underground Electrical Inspection - Commercial Passed 01/24/2006
Correction
Resolved
01/24/2006
EXTERIOR LIGHT POST AND SERVICE ENTRANCE UG CONDUIT TO LIGHT POLES + SERVICE ENTRANCE PIPING
Correction
Resolved
01/24/2006
PVC CONDUIT @ DRIVE-THROUGH CANOPY MATERIAL & WORKMANSHIP OK TO COVER WHEN READY
Underground Electrical Inspection - Commercial Request Complete 1/24/2006 1/24/2006 01/24/2006
Rough Framing Inspection - Commercial Partial 02/06/2006
Correction
Partial Correction
02/06/2006
COMMENTS APPROVED TO COVER OUTSIDE FACE OF EXTERIOR WALLS AS NOTED: FROM NORTH SIDE OF EAST ENTRY AROUND TO SOUTHWEST CORNER BY EDGE OF DRIVE-THROUGH BAYS. NOTE: SOME SCREWS NOT INSTALLED DUE TO OBSTRUCTIONS. TO REMAIN VISIBLE FOR IN-WALL INSPECTION.
Rough Framing Inspection - Commercial Request Complete 2/3/2006 2/6/2006 02/06/2006
Rough Framing Inspection - Commercial Partial 02/08/2006
Correction
Resolved
02/08/2006
COMMENTS
Correction
Partial Correction
02/08/2006
STEEL FRAMING @ EXTERIOR WALLS FROM NORTH SIDE OF EAST ENTRY AROUND TO SOUTHWEST CORNER BY EDGE OF DRIVE-THROUGH BAYS. NOTE: SOME SCREWS NOT INSTALLED DUE TO OBSTRUCTIONS. TO REMAIN VISIBLE FOR IN-WALL INSPECTION. OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
Correction
Partial Correction
02/08/2006
STEEL FRAMING @ MECHANICAL SCREEN WALL AT ROOF VERTICAL FRAMING FULL PERIMETER; OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
Rough Framing Inspection - Commercial Request Complete 2/7/2006 2/8/2006 02/08/2006
Rough Framing Inspection - Commercial Partial 02/16/2006
Correction
Corrective Action Required
02/16/2006
STEEL FRAMING UNABLE TO INSPECT. NEED TO VARIFY PLANS. PLEASE RECALL FOR INSPECTION OR CALL OFFICE. 969-7308
Rough Framing Inspection - Commercial Request Complete 2/15/2006 2/16/2006 02/16/2006
Rough Framing Inspection - Commercial Partial 02/21/2006
Correction
Resolved
02/21/2006
STEEL FRAMING @ EXTERIOR WALLS OK TO COVER WHEN READY
Correction
Resolved
02/21/2006
STEEL FRAMING @ MECHANICAL SCREEN WALL AT ROOF
Correction
Partial Correction
02/21/2006
STEEL FRAMING DRIVE THROUGH WALLS AND SOFFITS
Rough Framing Inspection - Commercial Request Complete 2/17/2006 2/21/2006 02/21/2006
Rough Framing Inspection - Commercial Not Ready 02/24/2006
Correction
Resolved
02/24/2006
STEEL FRAMING @ EXTERIOR WALLS
Correction
Resolved
02/24/2006
STEEL FRAMING
Correction
Corrective Action Required
02/24/2006
READINESS FOR INSPECTION + OBJECT OF INSPECTION NOT IDENTIFIED. NOT READY FOR INSPECTION OFFICE TRAILER LOCKED NOACCESS TO PERMIT PRINTS
Rough Framing Inspection - Commercial Partial 02/27/2006
Correction
Partial Correction
02/27/2006
STEEL FRAMING
Correction
Resolved
02/27/2006
READINESS FOR INSPECTION
Correction
Resolved
02/27/2006
FRAMING OF BOILER PLATFORM OK TO COVER WHEN READY
Rough Framing Inspection - Commercial Request Complete 2/24/2006 2/27/2006 02/27/2006
All Rough Inspection - Commercial Partial 03/03/2006
Correction
Partial Correction
03/03/2006
WALL FRAMING + IN-WALL SYSTEMS ROUGH PERIMETER WALLS EXCEPT FOR 113 AND @ WATER HYDRANTS; FRONT ENTRANCE TO CEILING HEIGHT; OK TO COVER WHEN READY PORTIONS LISTED BELOW:
All Rough Inspection - Commercial Partial 03/15/2006
Correction
Partial Correction
03/15/2006
WALL FRAMING + IN-WALL SYSTEMS ROUGH PERIMETER WALLS EXCEPT FOR 113, 113 IF IN-WALL GAS PIPING OK, 114; 115 FOUR WALLS; FRONT ENTRANCE TO CEILING HEIGHT; OK TO COVER WHEN READY PORTIONS LISTED BELOW:
Rough Plumbing Inspection - Commercial Passed 03/15/2006
Correction
Resolved
03/15/2006
DOMESTIC WATER PIPING AT STUD PENETRATIONS OK TO COVER WHEN READY WHEN ISOLATED FROM STEEL
Correction
Resolved
03/15/2006
ROOF DRAIN PIPING TO SATISFACTION OF G.C. PER IPC 312.3 OK TO COVER WHEN READY AFTER PRESSURE TEST
Correction
Resolved
03/15/2006
C.I. DWV PIPING TO SATISFACTION OF G.C. PER IPC 312.3 OK TO COVER WHEN READY AFTER PRESSURE TEST
Gas Piping Inspection - Commercial Passed 03/15/2006
Correction
Resolved
03/15/2006
VISUAL INSPECTION BLACK IRON GAS PIPING ARE ALLOWED PER SPEC IN WALL CAVITY OK TO COVER WHEN READY IF SCREWED FITTINGS
Gas Service Inspection - Commercial Passed 03/15/2006
Correction
Resolved
03/15/2006
PRESSURE TEST RELEASE SERVICE IF SCREWED JOINTS IN WALL CAVITY OK PER SPEC HELD STEADY @ > 10 PSI FOR > 30 MIN
Water Service Inspection Passed 03/22/2006
Correction
Resolved
03/22/2006
WATER SERVICE INSTALLATION
All Rough Inspection - Commercial Partial 03/28/2006
Correction
Partial Correction
03/28/2006
WALL FRAMING + IN-WALL SYSTEMS ROUGH PERIMETER WALLS EXCEPT FOR 113, 113 IF IN-WALL GAS PIPING OK, FRONT ENTRANCE TO CEILING HEIGHT; 109-120; 125-127; OK TO COVER WHEN READY PORTIONS LISTED BELOW:
Rated Assembly Inspection Partial 03/28/2006
Correction
Partial Correction
03/28/2006
FIRE-RATED WALLS GWB @ UPPER 4' OF WALL AT 124; OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
Rough Framing Inspection - Commercial Request Complete 3/27/2006 3/28/2006 03/28/2006
Rough Framing Inspection - Commercial Partial 03/31/2006
Correction
Resolved
03/31/2006
None APPROVED TO COVER ALL WALLS EXCEPT INTERIOR OF VAULT.
Rough Framing Inspection - Commercial Request Complete 3/30/2006 3/31/2006 03/31/2006
Rough Framing Inspection - Commercial Partial 04/05/2006
Correction
Partial Correction
04/05/2006
BOILER ROOM MEZZANINE APPROVED TO COVER
Rated Assembly Inspection Partial 04/05/2006
Correction
Partial Correction
04/05/2006
FIRE-RATED WALLS GWB @ UPPER 4' OF WALL AT 124; OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
Correction
Partial Correction
04/05/2006
MECHANICAL ROOM SCREW PATTERNS IN MECHANICAL ROOM FIRE RATED WALLS APPROVED. APPROVED TO COVER
Rough Framing Inspection - Commercial Request Complete 4/4/2006 4/5/2006 04/05/2006
Rated Assembly Inspection Partial 04/07/2006
Correction
Partial Correction
04/07/2006
MECHANICAL ROOM SCREW PATTERNS IN MECHANICAL ROOM FIRE RATED WALLS APPROVED. SCREW PATTERNS IN BOILER ROOM MEZZANINE FIRE RATED WALLS APPROVED. APPROVED TO COVER
Rough Electrical Inspection - Commercial Partial 04/10/2006
Correction
Partial Correction
04/10/2006
Metal Boxes (grounding) (IRC) SAFE ROOM ONLY
Rough Framing Inspection - Commercial Passed 04/10/2006
Correction
Resolved
04/10/2006
STEEL FRAMING SAFE - APPROVED
Correction
Resolved
04/10/2006
BOILER ROOM MEZZANINE APPROVED TO COVER
Rough Framing Inspection - Commercial Request Complete 4/7/2006 4/10/2006 04/10/2006
All Rough Inspection - Commercial Passed 04/18/2006
Correction
Resolved
04/18/2006
WALL FRAMING + IN-WALL SYSTEMS ROUGH PERIMETER WALLS EXCEPT FOR 113, 113 IF IN-WALL GAS PIPING OK, FRONT ENTRANCE TO CEILING HEIGHT; 109-120; 125-127; 117 OK TO COVER WHEN READY PORTIONS LISTED BELOW:
Above Ceiling Inspection Partial 04/18/2006
Correction
Partial Correction
04/18/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH NW ENTRANCE CANOPY OK, WITH ELECT LUMINAIRES TO BE INSTALLED WHEN RECEIVED; 117; OK TO COVER WHEN READY SPACES LISTED BELOW:
Sidewalk Inspection Passed 04/20/2006
Rated Assembly Inspection Failed 05/12/2006
Correction
Partial Correction
05/12/2006
MECHANICAL ROOM SCREW PATTERNS IN MECHANICAL ROOM FIRE RATED WALLS APPROVED. SCREW PATTERNS IN BOILER ROOM MEZZANINE FIRE RATED WALLS APPROVED. APPROVED TO COVER
Correction
Corrective Action Required
05/12/2006
Through Penetrations (IRC) ROOM 117 - 2 PENETRATIONS AT METAL TRUSSES CHILDREN'S AREA - NW CORNER - BOTH SIDES
Above Ceiling Inspection Partial 05/12/2006
Correction
Partial Correction
05/12/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH NW ENTRANCE CANOPY OK, WITH ELECT LUMINAIRES TO BE INSTALLED WHEN RECEIVED; 117; OK TO COVER WHEN READY SPACES LISTED BELOW:
Correction
Partial Correction
05/12/2006
See Comments PARIMETER ONLY - ROOMS 100, 102, 103, 104, 106, 107, 109, 114, 119, 120, 125, 127, 129, 130 OPEN J-BOXES - ROOMS 111,115, 121, 131 FYI - ROOM 114 - 2' X 4' LIGHTS NOT SUPPORTED
Electrical Service Inspection Passed 05/12/2006
Correction
Resolved
05/12/2006
None MDP - 400 AMP PANEL. RELEASE METER
Above Ceiling Inspection Partial 05/15/2006
Correction
Partial Correction
05/15/2006
See Comments PARIMETER ONLY - ROOMS 100, 102, 103, 104, 106, 107, 109, 114, 119, 120, 125, 127, 129, 130 OPEN J-BOXES - ROOMS 111,115, 121, 131 FYI - ROOM 114 - 2' X 4' LIGHTS NOT SUPPORTED
Correction
Partial Correction
05/15/2006
CEILING FRAMING + ABOVE CEILING ROUGH-IN WELCOME CENTER HARD COVER AT BOTTOM OF CIRCLE AND ADJACENT 2' WAVED BAND; OK TO COVER WHEN READY SPACES LISTED BELOW:
Above Ceiling Inspection Partial 05/17/2006
Correction
Partial Correction
05/17/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH NW ENT CANOPY OK, WITH ELECT LUMINAIRES TO BE INSTALLED; 117; WELCOME CTR HARD COVER AT BOTTOM OF CIRCLE & ADJ 2' WAVED BAND; PERIM ONLY @ 100, 102, 103, 104, 106, 107, 109, 114, 119, 120, 125, 127, 129, 130; E CANOPY; {OPEN JB'S @ 111,115, 121, 131} OK TO COVER WHEN READY SPACES LISTED BELOW:
Correction
Partial Correction
05/17/2006
See Comments FYI - ROOM 114 2' X 4' LITES NOT SPPTD
Correction
Resolved
05/17/2006
CEILING FRAMING + ABOVE CEILING ROUGH-IN SEE ELSEWHERE
Above Ceiling Inspection Partial 05/19/2006
Correction
Resolved
05/19/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH NW ENT CANOPY OK, WITH ELECT LUMINAIRES TO BE INSTALLED; 117; WELCOME CTR HARD COVER AT BOTTOM OF CIRCLE & ADJ 2' WAVED BAND; PERIM ONLY @ 100, 102, 103, 104, 106, 107, 109, 114, 119, 120, 125, 127, 129, 130; E CANOPY; OK TO COVER WHEN READY SPACES LISTED BELOW:
Correction
Resolved
05/19/2006
See Comments SEE ELSEWHERE
Correction
Partial Correction
05/19/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS (CONT'D) SPACES FOLOWING: 102-107; 109-117; 119-120; 125-127; 129-131; CLOSE BOXES; REMOVE TEMP OK TO COVER WHEN READY
Above Ceiling Inspection Passed 06/12/2006
Correction
Resolved
06/12/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH
Correction
Resolved
06/12/2006
See Comments
Correction
Resolved
06/12/2006
CEILING FRAMING + ABOVE CEILING ROUGH-IN AT 101 WELCOME CENTER OKTO COVER ALL WHEN READY 5 LIGHTS TO BE INSTALLED
Correction
Resolved
06/12/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS (CONT'D)
Occupancy Inspection - Codes Commercial Not Ready 06/12/2006
Correction
Partial Correction
06/12/2006
OCCUPANCY APPROVAL STATUS NO STAFF, PUBLIC, OR CUSTOMERS UNTIL APPROVED OK FOR COMPUTER SYSTEM INSTALLATION @ 110-115
Occupancy Inspection - Codes Commercial Not Ready 06/22/2006
Correction
Partial Correction
06/22/2006
OCCUPANCY APPROVAL STATUS AS OF 6/26/06 IF EXCISE TAX IS PAID NLT 6/23/06 OK FOR INSTALLATION OF FURNITURE AND PC EQPMT
Correction
Corrective Action Required
06/22/2006
LICENSE TAX DUE AND OWING NOT PAID PER RECORD
Correction
Resolved
06/22/2006
Receive Fire Department approval PER JOE DIR 6/22/06
Correction
Corrective Action Required
06/22/2006
Receive Water Utilities Approval CONTACT BEN HASKAMP PHONE 816-969-1930
Correction
Corrective Action Required
06/22/2006
Receive Planning & Development Approval CONTACT TOM SCANNEL SEE LIST PROVIDED
Correction
Corrective Action Required
06/22/2006
Receive Public Works Approval CONTACT BILL LYON PHONE 816-969-1800
Correction
Partial Correction
06/22/2006
READINESS FOR INSPECTION WHEN ELECTRICAL WORK TO BE ESSENTIALLY COMPLETED CODES ADMIN INSPECTION TO BE PERFORMED 6/23/06
Rough Electrical Inspection - Commercial Passed 06/22/2006
Correction
Resolved
06/22/2006
Metal Boxes (grounding) (IRC)
Rated Assembly Inspection Passed 06/22/2006
Correction
Resolved
06/22/2006
FIRE-RATED WALLS
Correction
Resolved
06/22/2006
MECHANICAL ROOM
Correction
Resolved
06/22/2006
Through Penetrations (IRC)
Footing Inspection - Commercial Passed 06/22/2006
Correction
Resolved
06/22/2006
PERIMETER SPREAD FOOTING & INTEGRAL COLUMN FOOTING PREP
Occupancy Inspection - Codes Commercial Failed 06/26/2006
Correction
Partial Correction
06/26/2006
OCCUPANCY APPROVAL STATUS SEE TEMPORARY OCCUPANCY
Correction
Resolved
06/26/2006
LICENSE TAX DUE AND OWING NOW PAID PER RECORD
Correction
Corrective Action Required
06/26/2006
Receive Planning & Development Approval CONTACT TOM SCANNELL PHONE 969-7317
Correction
Corrective Action Required
06/26/2006
Receive Public Works Approval CONTACT BILL LYON PHONE 816-969-1800
Correction
Resolved
06/26/2006
READINESS FOR INSPECTION
Correction
Corrective Action Required
06/26/2006
CONDENSATE LINES @ ROOF NOT SECURED TO BLOCKS
Correction
Corrective Action Required
06/26/2006
CONDENSATE LINE BEHIND LADDER TO ROOF IMPINGES ON FOOTHOLD
Correction
Corrective Action Required
06/26/2006
PENETRATIONS/HOLES IN EXTERIOR WALL IRC R703.1: SEAL HOLES & ANNULAR SPACES SOME NOT SEALED CHECK ALL E.G. @GAS ENTRY
Occupancy Inspection - Codes Commercial Failed 06/28/2006
Correction
Resolved
06/28/2006
CONDENSATE LINES @ ROOF SECURING TO BLOCKS IN PROGRESS
Correction
Resolved
06/28/2006
CONDENSATE LINE BEHIND LADDER TO ROOF
Correction
Resolved
06/28/2006
PENETRATIONS/HOLES IN EXTERIOR WALL
Occupancy Inspection - Codes Commercial Failed 07/07/2006
Correction
Resolved
07/07/2006
Receive Water Utilities Approval PER BEN HASKAMP
Occupancy Inspection - Codes Commercial Failed 07/13/2006
Correction
Resolved
07/13/2006
LICENSE TAX DUE AND OWING
Correction
Corrective Action Required
07/13/2006
Receive Planning & Development Approval TO BE COMPLETED & APPROVED PER DEVELOPMENT AGREEMENT SINGLE REMAINING ISSUE LANDSCAPING @ EAST P/L
Correction
Corrective Action Required
07/13/2006
Receive Public Works Approval AFFIDAVITS OF PAYMENT AND BOND TO BE PROVIDED CONTACT BILL LYON PHONE 816-969-1800
Correction
Resolved
07/13/2006
CONDENSATE LINES @ ROOF
Occupancy Inspection - Codes Commercial Failed 07/19/2006
Correction
Corrective Action Required
07/19/2006
Receive Planning & Development Approval TO BE COMPLETED & APPROVED PER DEVELOPMENT AGREEMENT SINGLE REMAINING ISSUE LANDSCAPING @ EAST P/L
Correction
Resolved
07/19/2006
Receive Public Works Approval PER BILL LYON 7/19/06
Occupancy Inspection - Codes Commercial Passed 08/29/2008
Correction
Resolved
08/29/2008
OCCUPANCY APPROVAL STATUS
Correction
Resolved
08/29/2008
Receive Planning & Development Approval PER BOB MCKAY 8/22/08
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home