Permit Application Status

B0501690


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0501690
Building Permit - Commercial
Certificate of Occupancy
DACUR INVESTMENT COMPANY INC
CHANGE OF TENANT
FRAMING, MISC. ELECTRICAL
09/15/2005
09/15/2005
03/14/2006
10/20/2005
Locations
Contacts
LITTLE GYM OF LEES SUMMIT, Address:853 NW OBRIEN RD  
DACUR INVESTMENT COMPANY INC, Address:2700 KENDALLWOOD PKWY # 208  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 03/14/2006 10/29/2010
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $59.00 $59.00 Paid 09/15/2005
25 Electrical Permit Fee $30.00 $30.00 Paid 09/15/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Not Ready 09/21/2005
Correction
Corrective Action Required
09/21/2005
READINESS FOR INSPECTION IBC 109.1, 109.5: NOT READY PROPERTY LOCKED INTERIOR NOT ACCESSIBLE
All Rough Inspection - Commercial Passed 09/22/2005
Correction
Resolved
09/22/2005
WALL FRAMING + IN-WALL SYSTEMS ROUGH OK TO COVER WHEN READY
Correction
Resolved
09/22/2005
READINESS FOR INSPECTION
Rough Framing Inspection - Commercial Passed 09/26/2005
Correction
Resolved
09/26/2005
LINTEL AT NEW PASS-THROUGH WINDOW IN CMU WALL OK TO COVER WHEN READY
Above Ceiling Inspection Partial 09/29/2005
Correction
Partial Correction
09/29/2005
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH EXCEPT OFFICE (NE) AREA NOT READY REMOVE COMBUSTIBLES OK TO COVER WHEN READY
Above Ceiling Inspection Failed 10/03/2005
Correction
Partial Correction
10/03/2005
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH OFFICE (NE) AREA ISSUES: 1) REMOVE COMBUSTIBLES ABOVE CEILING 2) REMOVE ABANDONED MATERIAL (E.G. STEEL ANGLE) 3) PLUG OPENING IN ELECT BOX EXERCISE AREA & LOBBY APPROVED EARLIER
Occupancy Inspection - Codes Commercial Failed 10/03/2005
Correction
Partial Correction
10/03/2005
OCCUPANCY APPROVAL STATUS SEE TEMPORARY OCCUPANCY
Correction
Corrective Action Required
10/03/2005
WATER HEATER RELIEF VALVE WASTE DISCHARGE IPC 504.6 NOT PIPED TO INDIRECT WASTE RECEPTOR
Correction
Corrective Action Required
10/03/2005
HANDICAPPED ACCESSIBLE RESTROOM SIGN NOT IN PLACE PER ADA/ANSI
Correction
Corrective Action Required
10/03/2005
WIRING OF ELECTRICAL RECEPTACLES CHECK ALL. ONE RECEPT AT WEST WALL BROKEN SOME WITH OPEN GROUNDS VARIOUS LOCATIONS
Correction
Corrective Action Required
10/03/2005
ELECT CIRCUIT BREAKERS COATED WITH PAINT CLEAN PAINT FROM HANDLE SO AMPS ARE READABLE
Correction
Corrective Action Required
10/03/2005
UNUSED CIRCUIT BREAKER OPENING IN ELECT PANEL NOT PROPERLY PLUGGED WEST PANEL
Correction
Corrective Action Required
10/03/2005
LABELING OF ELECTRICAL CIRCUIT BREAKERS IRC E36O6.2. EACH BREAKER MUST BE LABELED. MUST BE LEGIBLE; SPECIFIC. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE" INCOMPLETE/IMPROPER SERVICE PANEL SCHEDULE
Correction
Corrective Action Required
10/03/2005
LABELING OF ELECTRICAL SERVICE EQUIPMENT TWO METERS SERVING SPACE LABEL METERS PER PANEL
Correction
Corrective Action Required
10/03/2005
Receive Fire Department approval REAR DOOR LOCK CORRECTED. COMBINATION EMERGENCY LIGHT / EXIT SIGN INSTALLATION IN PROGRESS. PER LIST PROVIDED
Occupancy Inspection - Codes Commercial Failed 10/04/2005
Correction
Corrective Action Required
10/04/2005
INSTALLATION OF LIGHTED SIGN INSTALL NO NON-LISTED SIGN SIGN MUST BE LISTED PER NEC 600-3
Correction
Resolved
10/04/2005
WIRING OF ELECTRICAL RECEPTACLES CAUTION: IF/WHEN RECEPTACLES ARE REINSTALLED, ENSURE WIRING IS CODE-COMPLIANT. SOME WITH OPEN GROUNDS NOW ELIMINATED
Correction
Resolved
10/04/2005
ELECT CIRCUIT BREAKERS COATED WITH PAINT
Correction
Resolved
10/04/2005
UNUSED CIRCUIT BREAKER OPENING IN ELECT PANEL
Correction
Partial Correction
10/04/2005
Receive Fire Department approval REAR DOOR LOCK CORRECTED. COMBINATION EMERGENCY LIGHT / EXIT SIGN INSTALLED. PER LIST PROVIDED
Above Ceiling Inspection Passed 10/19/2005
Correction
Resolved
10/19/2005
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH
Occupancy Inspection - Codes Commercial Passed 10/19/2005
Correction
Resolved
10/19/2005
Receive Fire Department approval
Correction
Resolved
10/19/2005
LABELING OF ELECTRICAL SERVICE EQUIPMENT
Correction
Resolved
10/19/2005
LABELING OF ELECTRICAL CIRCUIT BREAKERS
Correction
Resolved
10/19/2005
WIRING OF ELECTRICAL RECEPTACLES
Correction
Resolved
10/19/2005
HANDICAPPED ACCESSIBLE RESTROOM SIGN
Correction
Resolved
10/19/2005
WATER HEATER RELIEF VALVE WASTE DISCHARGE
Correction
Resolved
10/19/2005
OCCUPANCY APPROVAL STATUS
Correction
Resolved
10/19/2005
INSTALLATION OF LIGHTED SIGN INSTALL NO NON-LISTED SIGN SIGN MUST BE LISTED PER NEC 600-3
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home