Summary
B0501552
Building Permit - Residential
Certificate of Occupancy
CLAUS DANIEL & STEPHANIE HOPE TRUSTEE
NEW SINGLE FAMILY
HOUSE AND DECK
08/29/2005
08/30/2005
02/26/2006
03/07/2006
Locations
Contacts
JAMES RAY BUILDERS, Address:4610 SW 11TH ST. CT.  
CLAUS DANIEL & STEPHANIE HOPE TRUSTEE, Address:3137 SW RAGAN DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 02/25/2006 10/29/2010
Correction

Codes Administration- Bedrooms located in basements shall have at least one operable window or door approved for emergency escape which opens to the exterior. All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet. The net clear openable height shall be 24 inches. The minimum net clear openable width shall be 20 inches. The finished sill height shall not exceed 44 inches above the finished floor. (UBC Section 1204).
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The holder of this permit agrees and understands that the work authorized by this permit shall be performed in accordance with the 2000 International Residential Code as amended by Chapter 7 of the Lee's Summit Code of Ordinances.
Correction

CA - The holder of this permit agrees and understands that only persons authorized per LSCO 7-130 are permitted to perform electrical, plumbing or mechanical work authorized by this permit.
Correction

In a combined effort with both the R-4, and the R-7 School Districts the City of Lee's Summit is working together to educate the development community on a new program, the "Lee's Summit Voluntary Residential Development Surcharge". This is a program, which will help raise capital to build new schools for our community. Brochures are available at the front counter of both the Planning and Development and the Codes Administration departments. You can also find more information on the City of Lee's Summit web site at lees-summit.mo.us. (For more information please contact the Board of Education at 986-2400).
Correction

CA - 2000 IRC 401.3 - Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 inches (152 mm) within the first 10 feet (3048 mm). 2000 IRC, Section 401.3
Correction

CA - 2000 IRC 403.1.6 - Foundation sills and exterior wall sole plates shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet on center. Anchor bolts shall be located within 12 inches from the end of each plate section. Anchor bolts shall be 1/2 inch in diameter and shall extend a minimum of 7 inches into the concrete. A nut and washer shall be tightened on each bolt to the plate. 2000 IRC, Section 403.1.6
Correction

CA - 2000 IRC 403.7.3 - The top of any exterior foundation shall extend above the elevation of the street curb or approved drainage device a minimum of 12" (twelve inches) plus 2%. Alternative elevations are permitted subject to approval of the building official, provided it can be demonstrated that required drainage to the point of discharge and away from the structure is provided at all locations on site. 2000 IRC, Section 403.7.3
Correction

CA - 2000 IRC 405.1 - Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or useable space. Drainage tiles, gravel drains or perforated pipe drainage systems shall be installed at or below the area to be protected and discharge by gravity or mechanical means. Perforated pipe shall be placed upon at least 2 inches of washed gravel or crushed rock and covered with not less than 6 inches of the same material. (2000 IRC, Section 405.1)
Correction

CA - 2000 IRC 703.9 - Foundation walls shall extend above the finished grade a minimum of 4 inches where masonry veneer is used and a minimum of 6 inches elsewhere. (2000 IRC, Section 404.1.6) Exterior Insulation Finish Systems, EFIS, shall terminate not less than 6 inches above finished grade. (2000 IRC, Section 703.9)
Correction

CA - 2000 IRC 314.3 - The minimum headroom in all parts of stairways shall not be less than 6 feet 8 inches measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-122 - Any excavation for foundations and/or footings of buildings and structures shall be backfilled within twenty-eight (28) days from the date of permit issuance unless otherwise approved by the building official.
Correction

CA - LSCO 7-128 (a)1 - Retaining walls which are over 4 feet in height measured from the bottom of the footing to the top of the wall of the wall shall be designed and sealed by a professional engineer or architect registered in the State of Missouri. In addition, the building official may waive the requirements for a permit or engineered drawings for walls over 4 feet in height if it is deemed unnecessary to require such submittals due to the location and type of wall to be installed.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-168 A - Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place before inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94; the concrete need not be on the job.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - LSCO 7-930 - All dwellings shall have a controlled method of water disposal from the roofs that will collect and discharge all roof drainage to the ground at least 3 feet from the foundation walls or to an approved drainage system.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $401.00 $401.00 Paid 08/30/2005
25 Electrical Permit Fee $102.95 $102.95 Paid 08/30/2005
25 Mechanical Permit Fees $55.00 $55.00 Paid 08/30/2005
25 Plumbing Permit Fees $40.00 $40.00 Paid 08/30/2005
84 Water Meters $125.00 $125.00 Paid 08/30/2005
85 Water Taps $2,734.00 $2,734.00 Paid 08/30/2005
89 Sewer Tap Fees $360.00 $360.00 Paid 08/30/2005
Right of Way Permit $35.00 $35.00 Paid 08/30/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 09/01/2005
Correction
Resolved
09/01/2005
NONE None -PERIMETER FOOTING, REAR BASEMENT WALKOUT TRENCH, 3 BASEMENT PADS, 2 GARAGE PAD-APPROVED
Miscellaneous Inspection Failed 09/19/2005
Correction
Corrective Action Required
09/19/2005
R325 Premises Identification (IRC) IDENTIFY PROPERTY
Erosion Control Inspection Residential Failed 09/19/2005
Correction
Corrective Action Required
09/19/2005
LSCO 5029 XX Erosion Control DEFICIENT EROSION CONTROL. ADD FENCE ON WEST SIDE OF LOT
Correction
Corrective Action Required
09/19/2005
LSCO5029XX2 Tracking Mud, Debris STREET CLEANUP REQUIRED.
Sewer Service Inspection - R Passed 09/19/2005
Water Service Inspection - R Partial 09/19/2005
Correction
Partial Correction
09/19/2005
NONE None APPROVED TO METER
Water Service Inspection - R Passed 09/19/2005
Underslab Plumbing Inspection - Residential Passed 09/19/2005
Sewer Service Inspection - Residential Request Complete 9/19/2005 9/19/2005 09/19/2005
Sewer Service Inspection - Residential Request Complete 9/19/2005 9/19/2005 09/19/2005
Erosion Control Inspection Residential Failed 11/22/2005
Correction
Corrective Action Required
11/22/2005
LSCO 5029 XX Erosion Control DEFICIENT EROSION CONTROL. ADD FENCE ON WEST SIDE OF LOT
Correction
Resolved
11/22/2005
LSCO5029XX2 Tracking Mud, Debris
All Rough Inspection - Residential Failed 11/22/2005
Correction
Corrective Action Required
11/22/2005
LSCO 3719 Erosion control REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
All Rough Inspection - Residential Failed 11/29/2005
Correction
Resolved
11/29/2005
LSCO 3719 Erosion control
Correction
Corrective Action Required
11/29/2005
R602.9 Cripple Walls (IRC) BRACE CRIPPLE WALLS IN GARAGE AND 1ST FLOOR PER CODE. FYI: A 2X4 DIAGONAL FROM BOTTOM PLATE TO TOP PLATE MIN 4 FT OUT FROM CORNER AND EVERY 25 FT IS ONE ACCEPTABLE MEAN OF BRACING
Correction
Corrective Action Required
11/29/2005
MISC NAIL RAFTERS TO CEILING JOISTS IN GARAGE WITH 3 8D FACE NAILS AND 2 16D TOE NAILS INTO WALL TOP PLATE
Correction
Corrective Action Required
11/29/2005
MISC FIREBLOCKING -FIREBLOCK ALL FLOOR/CEILING PENETRATIONS, IE PLUMBING TRAPS, HVAC, OPENINGS, ETC. -FIREBLOCK BASEMENT WALL SPACE FROM JOIST SPACE, FURDOWN -FIREBLOCK STAIR STRINGER FROM FURDOWN -FB 1ST FL HALLWAY DEAD SPACE FROM ATTIC
Correction
Corrective Action Required
11/29/2005
MISC SEAL RETURN AIR SPACE PENETRATIONS
Correction
Corrective Action Required
11/29/2005
MISC OVERFILLED ELECTRICAL BOXES WHERE REDMARKED-1ST FL BATH, 2 BASEMENT SWITCH BOXES AT BOTTOM STAIR LANDING
Correction
Corrective Action Required
11/29/2005
R502.9 Fastening (IRC) NAIL ALL JOISTS TO WALL TOP PLATE-BASEMENT
Correction
Corrective Action Required
11/29/2005
LSCO 7-905 Glazing at Hazardous Locations (IRC) TEMPERED GLASS WINDOW REQUIRED BY BASEMENT EGRESS DOOR
Correction
Corrective Action Required
11/29/2005
R502.8 Drilling and Notching (Dimensional) (IRC) -REINFORCE OVERNOTCHED DOUBLE JOIST FOR RETURN AIR-UNDER KITCHEN.
Correction
Corrective Action Required
11/29/2005
MISC TEXT OKAY TO INSULATE, DO NOT ROCK
Electrical Service Inspection Failed 11/29/2005
Correction
Corrective Action Required
11/29/2005
MISC CORRECT FOLLOWING -ONLY ONE NEUTRAL CONDUCTOR AT EACH LUG. EQUIPMENT GROUNDING CONDUCTORS SEPARATE FROM NEUTRAL -REMOVE BONDING OF GAS PIPING FROM SERVICE PANEL (GAS UTILITY REQUIREMENT BEFORE THEY RELEASE SERVICE)
Gas Piping Inspection - Residential Passed 11/29/2005
Gas Service Inspection - Residential Failed 11/29/2005
Correction
Corrective Action Required
11/29/2005
M2416.4.1 Gas Test Pressure (IRC) NEED MIN 10 PSI PRESSURE
Erosion Control Inspection Residential Failed 11/29/2005
Correction
Corrective Action Required
11/29/2005
LSCO 5029 XX Erosion Control DEFICIENT EROSION CONTROL. FENCE BOTTOM SHALL BE ENTRENCHED OR BURIED
Driveway Inspection Passed 11/30/2005
Sidewalk Inspection Passed 11/30/2005
All Rough Inspection - Residential Failed 12/08/2005
Correction
Resolved
12/08/2005
R602.9 Cripple Walls (IRC)
Correction
Resolved
12/08/2005
MISC NAIL RAFTERS TO CEILING JOISTS IN GARAGE
Correction
Corrective Action Required
12/08/2005
MISC FIREBLOCKING -FIREBLOCK ALL FLOOR/CEILING PENETRATIONS, IE PLUMBING TRAPS, HVAC, OPENINGS, ETC. -FIREBLOCK BASEMENT WALL SPACE FROM JOIST SPACE, FURDOWN -FB 1ST FL HALLWAY DEAD SPACE FROM ATTIC
Correction
Corrective Action Required
12/08/2005
MISC OVERFILLED ELECTRICAL BOXES WHERE REDMARKED- BASEMENT SWITCH BOX AT BOTTOM STAIR LANDING NOTE: 18 CU IN SWITCH BOX W/ 20 CU IN FILL-BASEMENT LIVING RM SWITCH BOX
Correction
Corrective Action Required
12/08/2005
R502.9 Fastening (IRC) NAIL ALL JOISTS TO WALL TOP PLATE-BASEMENT NOTE: AT WALL WHERE WATER SERVICE ENTERS THE BUILDING.
Correction
Corrective Action Required
12/08/2005
LSCO 7-905 Glazing at Hazardous Locations (IRC) TEMPERED GLASS WINDOW REQUIRED BY BASEMENT EGRESS DOOR
Correction
Resolved
12/08/2005
R502.8 Drilling and Notching (Dimensional) (IRC)
Correction
Corrective Action Required
12/08/2005
MISC TEXT OKAY TO INSULATE, DO NOT ROCK
Gas Service Inspection - Residential Failed 12/08/2005
Correction
Corrective Action Required
12/08/2005
M2416.4.1 Gas Test Pressure (IRC) NEED MIN 10 PSI PRESSURE. MAKE SURE TO FIX GAS PIPE LEAKAGE BEFORE CALLING FOR INSPECTION
Erosion Control Inspection Residential Passed 12/08/2005
Correction
Resolved
12/08/2005
LSCO 5029 XX Erosion Control
All Rough Inspection - Residential Passed 12/13/2005
Correction
Resolved
12/13/2005
MISC FIREBLOCKING
Correction
Resolved
12/13/2005
MISC SEAL RETURN AIR SPACE PENETRATIONS
Correction
Resolved
12/13/2005
MISC OVERFILLED ELECTRICAL BOXES
Correction
Resolved
12/13/2005
R502.9 Fastening (IRC)
Correction
Resolved
12/13/2005
LSCO 7-905 Glazing at Hazardous Locations (IRC)
Correction
Resolved
12/13/2005
MISC TEXT OKAY TO ROCK
Gas Service Inspection - Residential Passed 12/13/2005
Correction
Resolved
12/13/2005
M2416.4.1 Gas Test Pressure (IRC) APPROVED FOR RELEASE
Erosion Control Inspection Residential Failed 12/19/2005
Correction
Corrective Action Required
12/19/2005
LSCO 5029 XX Erosion Control REPAIR SILT FENCE ALONG STREET. INSTALL SILT FENCE AT SE CORNER AND SW CORNER OF LOT WHERE MUD TRACKS INTO STREET. OR PROVIDE GRAVEL FILTER AT THESE LOCATIONS
Correction
Corrective Action Required
12/19/2005
MISC EROSION CONTROL SIGN POSTED -19-DEC-05
Electrical Service Inspection Passed 02/13/2006
Correction
Resolved
02/13/2006
MISC CORRECT FOLLOWING APPROVED FOR RELEASE OF 1-200 AMP SERVICE
Occupancy Inspection - Codes Residential Failed 02/13/2006
Correction
Corrective Action Required
02/13/2006
MISC WHITE ELECTRICAL CONDUCTORS TO A/C SHALL BE PROPERLY IDENTIFIED WITH APPROPRIATE COLOR AT PANEL AND AT A/C DISCONNECT
Sidewalk Inspection Passed 02/22/2006
Miscellaneous Inspection Passed 02/27/2006
Correction
Resolved
02/27/2006
R325 Premises Identification (IRC)
Occupancy Inspection - Codes Residential Failed 02/27/2006
Correction
Resolved
02/27/2006
MISC WHITE ELECTRICAL CONDUCTORS TO A/C SHALL BE PROPERLY IDENTIFIED
Correction
Corrective Action Required
02/27/2006
MISC SOD/36" SPLASHBLOCKS -ALSO PROVIDE MIN 6" CLEARANCE OF SIDING TO GRADE
Correction
Corrective Action Required
02/27/2006
MISC TOP OF WATER METER SHALL BE 14"-18" BELOW LID
Correction
Corrective Action Required
02/27/2006
MISC SEALING EXTERIOR -SEAL A/C CONDENSATING LINE AT WALL PENETRATION -SEAL ABOVE DECK GFCI RECEPTICLE
Correction
Corrective Action Required
02/27/2006
MISC EXPOSE AND EXTEND FOUNDATION WALL DRAINAGE AT NORTH SIDE
Correction
Corrective Action Required
02/27/2006
MISC SECURE DISH WASHER LOOP DRAIN TO UNDERSIDE OF COUNTERTOP
Correction
Corrective Action Required
02/27/2006
MISC PROVIDE MIN 12" CLEARANCE FROM CLOSET SHELF TO INCANDESCENT LIGHT @ BASEMENT BEDROOM. OR PROVIDE FLOURESCENT LIGHT WHICH REQUIRES ONLY 6" CLEARANCE
Correction
Corrective Action Required
02/27/2006
MISC BAR GFCI RECEPTICLE NOT TRIPPING
Occupancy Inspection - Codes Residential Failed 02/28/2006
Correction
Resolved
02/28/2006
MISC TOP OF WATER METER SHALL BE 14"-18" BELOW LID OK PER OLD STANDARD
Correction
Resolved
02/28/2006
MISC SEALING EXTERIOR
Correction
Resolved
02/28/2006
MISC EXPOSE AND EXTEND FOUNDATION WALL DRAINAGE AT NORTH SIDE
Correction
Resolved
02/28/2006
MISC SECURE DISH WASHER LOOP DRAIN TO UNDERSIDE OF COUNTERTOP
Correction
Resolved
02/28/2006
MISC PROVIDE MIN 12" CLEARANCE FROM CLOSET SHELF TO INCANDESCENT LIGHT
Correction
Resolved
02/28/2006
MISC BAR GFCI RECEPTICLE NOT TRIPPING
Erosion Control Inspection Residential Passed 03/06/2006
Correction
Resolved
03/06/2006
LSCO 5029 XX Erosion Control
Correction
Resolved
03/06/2006
MISC EROSION CONTROL SIGN POSTED
Occupancy Inspection - Codes Residential Passed 03/06/2006
Correction
Resolved
03/06/2006
MISC SOD/36" SPLASHBLOCKS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents