Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 02/22/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1004.3 - Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

Codes Administration - 2003 IBC 1110.1 - Signs. Required accessible elements shall be identified by the International Symbol of Accessiblity a the following locations: 1. Accessible parking spaces required by Section 1106.1 except where the total number of parking spaces provided is four or less. 2. Accessible passenger loading zones. 3. Accessbile areas of refuge required by Section 1007.6. 4. Accessible rooms where multiple single-user toilet or bathing rooms are clustered in a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the checkout aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting and locker rooms where not all such rooms are accessible.
Correction

Codes Administration - 2003 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as defined in Section 2406.3 shall comply with Sections 2406.1 through 2406.1.5.
Correction

Codes Administration - 2003 IBC 302.1.1.1 - Separation. Where Table 302.1.1 requires a fire-resistance-rated separation, the incidental use area shall be separated fron the remainder of the building with a fire barrier. Where Table 302.1.1 permits an automatic fire-extinguishing system without a fire barrier, the incidential use area shall be separated by construction capable of resisting the passage of smoke. The partitions shall extend fron the floor to the underside of the fire-resistance-rated floor/ceiling assembly or fire-resistance-rated roof/ceiling assembly or to the underside of the floor or roof deck above. Doors shall be self-closing or automatic-closing upon detection of smoke. Doors shall not have air transfer openings and shall not be undercut in excess of the clearance permitted in accordance with NFPA 80.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department- 1004.3 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

Codes Administration - I am unable to locate a interior finish schedule.
Correction

Codes Administration - Door 122A is existing and swings into the space. Although it is not a required egress door, the Codes Administration Department would prefer that the swing of this door be changed to swing out. In an emergency situation the inward swing of this door could possible cause injuries to those utilizing the facility.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department: Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the code official is authorized to require a key box to be installed in an accessible location. The key box shall be of an approved type and shall contain keys to gain access as required by the code official.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. The plans and specifications shall bear a State of Missouri licensed engineers seal. This includes fire sprinkler systems, grease hood and duct suppression systems as well as other fire suppression system.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm-initiating and notification appli- ances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing informa- tion for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - All exterior mechanical equipment, whether roof mounted or ground mounted, shall be screened from view from off the property. The appearance of screens shall be coordinated with the building to maintain a unified appearance.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $1,352.00 $1,352.00 Paid 08/30/2005
24 BLDG Plan Check Fees $42.50 $42.50 Paid 08/30/2005
25 Electrical Permit Fee $435.00 $435.00 Paid 08/30/2005
25 Mechanical Permit Fees $79.00 $79.00 Paid 08/30/2005
25 Plumbing Permit Fees $77.00 $77.00 Paid 08/30/2005
89 Sewer Tap Fees $120.00 $120.00 Paid 08/30/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Partial 02/23/2006
Correction
Partial Correction
02/23/2006
None 4 INCH SEWER TIED INTO EXISTING SEWER. 4 INCH CLEAN OUT INSTALLED. 4 INCH SEWER RUN INTO FUTURE BATHROOM.
Underslab Plumbing Inspection - Commercial Passed 02/24/2006
Correction
Resolved
02/24/2006
None 4 INCH SEWER TIED INTO EXISTING SEWER. 4 INCH CLEAN OUT INSTALLED. 4 INCH SEWER RUN INTO FUTURE BATHROOM.
Correction
Resolved
02/24/2006
None FINISHED ON 2/24/06
All Rough Inspection - Commercial Failed 05/16/2006
Correction
Resolved
05/16/2006
None WALLS ONLY - ABOVE CEILING TO BE INSPECTED AT A LATER DATE OK TO INSULATE OK TO DRYWALL
Correction
Corrective Action Required
05/16/2006
Metal Boxes (grounding) (IRC) NIT ALL ELECTRICAL BOXES ARE BONDED (WIRE HAS YET TO BE PULLED). CALL IN FOR AN INSPECTION TO ENSURE THAT ALL BOXES ARE APPROVED THROUGHOUT
All Rough Inspection - Commercial Passed 08/10/2006
Correction
Resolved
08/10/2006
Metal Boxes (grounding) (IRC) NIT ALL ELECTRICAL BOXES ARE BONDED (WIRE HAS YET TO BE PULLED). CALL IN FOR AN INSPECTION TO ENSURE THAT ALL BOXES ARE APPROVED THROUGHOUT
Above Ceiling Inspection Passed 08/10/2006
Correction
Resolved
08/10/2006
None ALL DROP CEILING AREAS ARE APPROVED
Occupancy Inspection - Codes Commercial Failed 08/25/2006
Correction
Corrective Action Required
08/25/2006
Unused Openings (IRC) WIRE REQUIRED TO TERMINATE W/N J-BOX OR FIXTURE EXTERIOR
Correction
Corrective Action Required
08/25/2006
ACCESSIBILITY ISSUES 1. GUARDS PLACED AT PLUMBING 2. STOOL - SIZING AND HANDRAILS MENS RESTROOM WOMENS RESTROOM
Correction
Corrective Action Required
08/25/2006
Identification of Disconnecting Means (IRC) ANY APPLIANCE OVER 20 AMPS THAT IS HARD WIRED IS REQUIRED TO HAVE A LOCKABLE DEVICE AT BREAKER Mechanical Room
Correction
Corrective Action Required
08/25/2006
ACCESSIBILITY ISSUE THRESHOLD REQUIRED AT FLOOR LEVEL CHANGE - CONCRETE TO WOOD FLOOR Kitchen area
Correction
Corrective Action Required
08/25/2006
FINISH PLUMBING WASTE LINE TO BE FINISHED FOR SINK - P OR S TRAP Kitchen
Correction
Corrective Action Required
08/25/2006
VENTING REQUIREMENTS FINISH VENTING APPLIANCES Kitchen
Correction
Corrective Action Required
08/25/2006
THROUGH PENETRATION CAP MECHANICAL VENT UTILITY ROOM
Correction
Corrective Action Required
08/25/2006
STAIR REQUIREMENTS STAIR HEIGHT REQUIRMENTS ARE NOT MET AUDITORIUM
Correction
Resolved
08/25/2006
Receive Water Utilities Approval
Correction
Corrective Action Required
08/25/2006
Receive Planning & Development Approval SEE SEPERATE COVER
Correction
Partial Correction
08/25/2006
Receive Fire Department approval SEE SEPERATE COVER
Occupancy Inspection - Codes Commercial Failed 10/20/2006
Correction
Resolved
10/20/2006
Unused Openings (IRC) WIRE REQUIRED TO TERMINATE W/N J-BOX OR FIXTURE EXTERIOR
Correction
Resolved
10/20/2006
ACCESSIBILITY ISSUES 1. GUARDS PLACED AT PLUMBING 2. STOOL - SIZING AND HANDRAILS MENS RESTROOM WOMENS RESTROOM
Correction
Partial Correction
10/20/2006
Identification of Disconnecting Means (IRC) -ANY APPLIANCE OVER 20 AMPS THAT IS HARD WIRED IS REQUIRED TO HAVE A LOCKABLE DEVICE AT BREAKER - PASS -ROOFTOP = WIRING AND DISCONNECT HAVE BEEN LEFT EXPOSED - 2 SMALLER UNITS Mechanical Room
Correction
Resolved
10/20/2006
ACCESSIBILITY ISSUE THRESHOLD REQUIRED AT FLOOR LEVEL CHANGE - CONCRETE TO WOOD FLOOR Kitchen area
Correction
Resolved
10/20/2006
FINISH PLUMBING WASTE LINE TO BE FINISHED FOR SINK - P OR S TRAP Kitchen
Correction
Resolved
10/20/2006
VENTING REQUIREMENTS FINISH VENTING APPLIANCES Kitchen
Correction
Resolved
10/20/2006
THROUGH PENETRATION CAP MECHANICAL VENT UTILITY ROOM
Correction
Resolved
10/20/2006
STAIR REQUIREMENTS STAIR HEIGHT REQUIRMENTS ARE NOT MET AUDITORIUM
Correction
Resolved
10/20/2006
Receive Fire Department approval SEE SEPERATE COVER
Correction
Partial Correction
10/20/2006
None 30 DAY TCO
Occupancy Inspection - Codes Commercial Passed 11/01/2006
Correction
Resolved
11/01/2006
Identification of Disconnecting Means (IRC) Mechanical Room
Correction
Resolved
11/01/2006
Receive Planning & Development Approval
Correction
Resolved
11/01/2006
None
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home