Permit Application Status

B0501278


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0501278
Building Permit - Commercial
Certificate of Occupancy
LEES LANDING PROPERTIES LLC
NEW TENANT FINISH
BODYFIT STUDIO TENANT FINISH
07/19/2005
08/05/2005
02/01/2006
02/15/2006
Locations
Contacts
MEMCO ENTERPRISES, Address:14219 KENNEDY RD  
LEES LANDING PROPERTIES LLC, Address:2270 NW SUMMERFIELD DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/15/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1008.1.1 - Size of doors. The minimum width of each door opening shall be sufficient for the occupant load thereof and shall provide a clear width of not less than 32 inches. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees. Where this section requires a minimum clear width of 32 inches and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches. The maximum width of a swinging door leaf shall be 48 inches nominal. Means of egress doors in an occupancy in Group I-2 used for the movement of beds shall provide a clear width not less than 41.5 inches. The height of doors shall not be less than 80 inches.
Correction

Codes Administration - 2003 IBC 1008.1.8.1 - Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 shall not require tight grasping, tight pinching or twisting of the wrist to operate.
Correction

Codes Administration - 2003 IBC 1014.2.1 - Two exits or exit access doorways. Where two exits or exit doorways are required from any portion of the exit access, the exit doors or exit access doorways shall be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the building or area to be served measured in a straight line between exit doors or exit access doorways. Interlocking or scissor stairs shall be counted as one exit stairway.
Correction

Codes Administration - 2003 IBC 1109.2 - Toilet and bathing facilities. Toilet rooms and bathing facilities shall be accessible. Where a floor level is not required to be connected by an accessible route, the only toilet rooms or bathing facilities provided within the facility shall not be located on the inaccessible floor. At least one of each type of fixture, element, control or dispenser in each accessible toilet room and bathing facility shall be accessible.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department- The exit door shall be clearly identifiable. Provide an exit sign if the other doors will not be used for exiting.
Correction

Codes Administration - Information has not been provided for the electrical installation.
Correction

Codes Administration - The plans do not indicate if there will be any alterations to the mechanical system.
Correction

Codes Adminsitration - Details have not been provided for the wall construction.
Correction

Codes Administration - Exit signage and emergency lighting is now required as two exits are required for the space.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IMC 403.3 - Ventilation rate. Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and occupant load or other parameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less than the number determined fron the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall b designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

Codes Administration - 2003 IPC 403.2 - Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $77.00 $77.00 Paid 08/05/2005
24 BLDG Plan Check Fees $8.25 $8.25 Paid 08/05/2005
25 Electrical Permit Fee $30.00 $30.00 Paid 08/05/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Failed 08/19/2005
Correction
Corrective Action Required
08/19/2005
Stud Drilling and Notching (IRC) EXTERIOR STUD OVERDRILLED. PROVIDE ADDITIONAL BEARING STUD OR STUD SHOE. MASSAGE ROOM
Correction
Corrective Action Required
08/19/2005
Water/DWV Preotection Against Physical Damage (IRC) PROVIDE NAIL GUARDS ON EACH SIDE OF STUD AT HOSE BIBB PIPING. MASSAGE ROOM
Correction
Partial Correction
08/19/2005
None OK TO INSULATE DO NOT ROCK
All Rough Inspection - Commercial Passed 08/23/2005
Correction
Resolved
08/23/2005
Stud Drilling and Notching (IRC)
Correction
Resolved
08/23/2005
Water/DWV Preotection Against Physical Damage (IRC)
Correction
Resolved
08/23/2005
None
Correction
Resolved
08/23/2005
INSULATION & GYPSUM WALLBOARD WHEN READY OK TO INSULATE OK TO INSTALL GWB
Above Ceiling Inspection Passed 09/27/2005
Correction
Resolved
09/27/2005
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH OK TO COVER WHEN READY
Occupancy Inspection - Codes Commercial Failed 10/03/2005
Correction
Resolved
10/03/2005
RESTROOM SIGNS
Correction
Resolved
10/03/2005
Receive Fire Department approval 1) SINGLE ADDRESS 2) MOUNT FIRE EXTINGUISHERS OK PER N ULLERY 10/3/05 CONTINGENT ON CONDITIONS
Correction
Corrective Action Required
10/03/2005
APPROVAL STATUS OF BUILDING SHELL PERMIT AWAITING RESOLUTION OF OUTSTANDING ISSUES
Gas Service Inspection - Commercial Not Ready 10/05/2005
Correction
Corrective Action Required
10/05/2005
TEST PRESSURE LEVEL ON SERVICE LINES #6, #7, #8 SERVICE LINE #7 NO TEST PRESSURE -- CALL WHEN READY HELD STEADY AT >= 10 PSI FOR >=10 MIN
Gas Piping Inspection - Commercial Passed 10/05/2005
Gas Service Inspection - Commercial Not Ready 10/11/2005
Correction
Partial Correction
10/11/2005
TEST PRESSURE LEVEL ON SERVICE LINES #6, #7, #8 SERVICE LINE #9 TEST PRESSURE < 10 PSI MINIMUM -- CALL WHEN READY HELD STEADY AT >= 10 PSI FOR >=10 MIN
Gas Service Inspection - Commercial Passed 10/14/2005
Correction
Resolved
10/14/2005
TEST PRESSURE LEVEL SVC LINES #6, #7, #8, #9 RELEASE SERVICE
Occupancy Inspection - Codes Commercial Passed 02/14/2006
Correction
Resolved
02/14/2006
Receive Fire Department approval
Correction
Resolved
02/14/2006
APPROVAL STATUS OF BUILDING SHELL PERMIT
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home