Permit Application Status

B0500865


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0500865
Building Permit - Commercial
Certificate of Occupancy
BANK MIDWEST NA
NEW COMMERCIAL
NEW COMMERCIAL
05/24/2005
07/21/2005
01/17/2006
09/02/2008
Locations
Contacts
BELL/KNOTT & ASSOCIATES, Address:106 W 11TH SUITE 2200  
TITAN CONSTRUCTION ORGANIZATION, Address:11865 S CONLEY  
BANK MIDWEST NA, Address:1111 MAIN ST STE 1600  
BANK MIDWEST NA, Address:1111 MAIN ST STE 2600  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/16/2006 10/29/2010
Correction

Codes Administration - ANSI A117.1-1998 804.7.6 - Refrigerator/Freezer. Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches maximum above the floor or ground. The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches maximum from the centerline of the dedicated space.
Correction

Codes Administration - 2003 IBC 1109.12.3 - Point of sales and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed.
Correction

Codes Administration - 2003 IBC 1110.1 - Signs. Required accessible elements shall be identified by the International Symbol of Accessiblity a the following locations: 1. Accessible parking spaces required by Section 1106.1 except where the total number of parking spaces provided is four or less. 2. Accessible passenger loading zones. 3. Accessbile areas of refuge required by Section 1007.6. 4. Accessible rooms where multiple single-user toilet or bathing rooms are clustered in a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the checkout aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting and locker rooms where not all such rooms are accessible.
Correction

Codes Administration - 2003 IBC 1203.2 - Attic spaces. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing members shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain and snow. Blocking and bridging shall be arranged so as not to interfere with the movement of air. A minimum of 1 inch of airspace shall be provided between the insulation and the roof sheathing. The net free ventilation area shall not be less than 1/150 of the area of the space ventilated, with 50 percent of the required ventilation area provided by ventilatiors located in the upper portion of the space to be ventilated at least 3 feet above eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents.
Correction

Codes Administration - 2003 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as defined in Section 2406.3 shall comply with Sections 2406.1 through 2406.1.5.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Codes Administration - ( As ammended) A 6-foot vinyl fence with masonry pilasters spaced 50 feet on center shall be provided for this development and a low impact screen per the UDO requirements shall be provided on the west side of the fence. The wall and berm system as described shall be constructed for the entire length of the property and completed prior to any occupancies being given for any of the five buildings shown on the plan.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department: Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the code official is authorized to require a key box to be installed in an accessible location. The key box shall be of an approved type and shall contain keys to gain access as required by the code official.
Correction

Fire Department; Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the code official.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $2,102.00 $2,102.00 Paid 07/21/2005
24 BLDG Plan Check Fees $55.00 $55.00 Paid 07/21/2005
25 Electrical Permit Fee $144.21 $144.21 Paid 07/21/2005
25 Mechanical Permit Fees $42.00 $42.00 Paid 07/21/2005
25 Plumbing Permit Fees $73.00 $73.00 Paid 07/21/2005
84 Water Meters $625.00 $625.00 Paid 07/21/2005
89 Sewer Tap Fees $180.00 $180.00 Paid 07/21/2005
Right of Way Permit $35.00 $35.00 Paid 07/21/2005
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Partial 08/16/2005
Correction
Partial Correction
08/16/2005
TEMPORARY ELECTRICAL SERVICE INSTALLATION PLUG 2 UNUSED OPENINGS IN PANEL IN OFFICE TRAILER. PROTECT FEEDER RACEWAY AND CABLE LYING EXPOSED FROM DISCONNECT TO TRAILER. 100 AMP RELEASE SERVICE
Footing Inspection - Commercial Partial 09/09/2005
Correction
Partial Correction
09/09/2005
PERIMETER GRADE BEAM + INTEGRAL COLUMN FOOTINGS FROM (B/1) TO (E/1) TO (E/4) TO (B/4); OK TO POUR WHEN READY SEGMENTS LISTED BELOW:
Footing Inspection - Commercial Partial 09/12/2005
Correction
Partial Correction
09/12/2005
PERIMETER GRADE BEAM + INTEGRAL COLUMN FOOTINGS FROM (B/1) TO (E/1) TO (E/4) TO (B/4); WEST WALL + REMAINDER OF S & N WALLS TO COMPLETE PERIMETER; OK TO POUR WHEN READY SEGMENTS LISTED BELOW:
Correction
Partial Correction
09/12/2005
ISOLATED COLUMN FOOTINGS -- BUILDING INTERIOR POUR AT RISK, PENDING VERIFICATION OF DESIGN CHANGES NOT REFLECTED IN PERMIT DRAWINGS. PER REVISIONS ON-SITE PROVIDE A/E DOCUMENTATION
Footing Inspection - Commercial Partial 09/19/2005
Correction
Resolved
09/19/2005
ISOLATED COLUMN FOOTINGS -- DRIVE-THROUGH CANOPY OK TO POUR WHEN READY
Underslab Electrical Inspection - Commercial Passed 09/20/2005
Correction
Resolved
09/20/2005
UNDER-FLOOR ELECTRICAL CONDUIT/BOXES OK TO COVER WHEN READY
Underslab Plumbing Inspection - Commercial Passed 09/20/2005
Correction
Resolved
09/20/2005
UNDER-SLAB DWV PIPING OK TO COVER WHEN READY
Underground Plumbing Inspection - Commercial Passed 09/21/2005
Correction
Resolved
09/21/2005
UNDERGROUND ROOF DRAIN PIPING PROVIDE CLEANOUT PER DRAWINGS OK TO COVER WHEN READY AT DRIVE-THROUGH CANOPY
Underground Electrical Inspection - Commercial Passed 09/26/2005
Correction
Resolved
09/26/2005
SECONDARY ELECTRICAL SERVICE READY FOR CONCRETE ENCASEMENT PER AQUILA REQUIREMENT 4" SCH 40 PVC CONDUIT TRENCHED >=36" DEEP
Water Service Inspection Partial 09/30/2005
Correction
Partial Correction
09/30/2005
WATER SERVICE INSTALLATION OK TO COVER WHEN READY FROM BUILDING ENTRY TO WEST BLDG LINE
Water Service Inspection - Commercial Request Complete 9/29/2005 9/30/2005 09/30/2005
Sewer Service Inspection Partial 10/11/2005
Correction
Partial Correction
10/11/2005
SEWER SERVICE INSTALLATION OK TO COVER WHEN READY FROM BUILDING ENTRY TO 100' WEST (C.O. @ 80')
Sewer Service Inspection - Commercial Request Complete 10/11/2005 10/11/2005 10/11/2005
Footing Inspection - Commercial Passed 10/17/2005
Correction
Resolved
10/17/2005
PERIMETER GRADE BEAM + INTEGRAL COLUMN FOOTINGS
Correction
Resolved
10/17/2005
ISOLATED COLUMN FOOTINGS -- BUILDING INTERIOR
Correction
Resolved
10/17/2005
ISOLATED COLUMN FOOTINGS -- DRIVE-THROUGH CANOPY
Sewer Service Inspection Passed 10/17/2005
Correction
Resolved
10/17/2005
SEWER SERVICE INSTALLATION OK TO COVER WHEN READY FROM BUILDING ENTRY TO 5' FROM TAP @ MAIN
Rough Framing Inspection - Commercial Partial 12/08/2005
Correction
Partial Correction
12/08/2005
SHEAR WALL (1): (D) - (E); (E): (1) - (2); (E): (3) - (4); (4): (D) - (E); SILL PLATE ANCHORAGE NOT APPROVED; LENGTH OF BOLTS PREPARED TO BE EPOXIED INTO FOUNDATION IS NOT COMPLIANT WITH STRUCTURAL DRAWING; PROVIDE 3RD PARTY VERIFICATION OF BOLT INSTALLATION SHEATHING ONLY OK TO COVER WHEN READY
Rough Framing Inspection - Commercial Request Complete 12/7/2005 12/8/2005 12/08/2005
All Rough Inspection - Commercial Partial 12/15/2005
Correction
Partial Correction
12/15/2005
WALL FRAMING + IN-WALL SYSTEMS ROUGH GIRDER TRUSSES @ TOWER HAVE NO TIE-DOWN HARDWARE OK TO COVER WHEN READY SPACES EXCEPT @ WET WALLS
All Rough Inspection - Commercial Passed 12/19/2005
Correction
Resolved
12/19/2005
WALL FRAMING + IN-WALL SYSTEMS ROUGH GIRDER TRUSSES @ TOWER HAVE NO TIE-DOWN HARDWARE; TO BE REINSPECTED AT OR BEFORE FINAL INSPECTION. PROTECT PVC PIPING OK TO COVER WHEN READY
Sidewalk Inspection Partial 01/03/2006
Gas Piping Inspection - Commercial Failed 01/05/2006
Correction
Corrective Action Required
01/05/2006
ROOFTOP PIPING SUPPORTS NOT PER DETAIL; DIRT LEGS NOT PER DETAIL NOT PER APPROVED DRWG SEE PLUMBING DETAILS
Gas Service Inspection - Commercial Not Ready 01/05/2006
Correction
Corrective Action Required
01/05/2006
READINESS FOR INSPECTION NOT READY FOR PRESS TEST B/C PIPING NOT APPROVED
Electrical Service Inspection Passed 01/05/2006
Correction
Resolved
01/05/2006
TEMPORARY ELECTRICAL SERVICE INSTALLATION
Correction
Resolved
01/05/2006
ELECTRICAL SERVICE INSTALLATION RELEASE SERVICE. ENSURE PANEL FRONTS ARE IN PLACE BEFORE REQUESTING SERVICE ACTIVATION. REVISED TO 225 AMP PER PR-1
Gas Service Inspection - Commercial Not Ready 01/09/2006
Correction
Resolved
01/09/2006
READINESS FOR INSPECTION
Correction
Corrective Action Required
01/09/2006
GUAGE OPERATION USE WORKING GUAGE WILL NOT ZERO WHEN DE-PRESSURED
Gas Service Inspection - Commercial Failed 01/10/2006
Correction
Resolved
01/10/2006
GUAGE OPERATION
Correction
Corrective Action Required
01/10/2006
TEST PRESSURE LEVEL PRESSURIZE PIPING SYSTEM TO HOLD STEADY DECREASED DURING MONITORING PERIOD
Gas Service Inspection - Commercial Passed 01/11/2006
Correction
Resolved
01/11/2006
TEST PRESSURE LEVEL RELEASE GAS SERVICE HELD STEADY AT 30 PSI FOR >= 20 MIN
Rough Framing Inspection - Commercial Passed 01/17/2006
Correction
Resolved
01/17/2006
SHEAR WALL
Gas Piping Inspection - Commercial Passed 01/17/2006
Correction
Resolved
01/17/2006
ROOFTOP PIPING
Above Ceiling Inspection Failed 01/17/2006
Correction
Corrective Action Required
01/17/2006
TEMPORARY ELECTRICAL WIRING NOT REMOVED SOME AREAS
Correction
Corrective Action Required
01/17/2006
LOW VOLTAGE ELECTRICAL WIRING WORK IN PROGRESS SUBJECT TO APPROVAL
Correction
Corrective Action Required
01/17/2006
PLUMBING PIPE INSULATION INCOMPLETE JOINTS NOT SEALED
Correction
Corrective Action Required
01/17/2006
BUILDING WALL INSULATION INCOMPLETE WALL CAVITIES NOT FILLED
Correction
Corrective Action Required
01/17/2006
PAPER FACED INSULATION SEE "WARNING" ON FACE OF MATERIAL LEFT EXPOSED CONTRARY TO MFGR WARNING
Correction
Corrective Action Required
01/17/2006
SCOPE OF 1/17/06 INSPECTION INT CEILING AREAS ONLY CANOPY NOT READY FOR INSP
Above Ceiling Inspection Passed 01/20/2006
Correction
Resolved
01/20/2006
TEMPORARY ELECTRICAL WIRING
Correction
Resolved
01/20/2006
LOW VOLTAGE ELECTRICAL WIRING
Correction
Resolved
01/20/2006
PLUMBING PIPE INSULATION
Correction
Resolved
01/20/2006
BUILDING WALL INSULATION COMPLETE CORRECTIONS AT WEST WALL
Correction
Resolved
01/20/2006
PAPER FACED INSULATION COMPLETE CORRECTIONS AT WEST WALL
Correction
Resolved
01/20/2006
SCOPE OF 1/17/06 INSPECTION
Correction
Resolved
01/20/2006
CEILING FRAMING + ABOVE-CEILING SYSTEMS ROUGH BUILDING + CANOPY OK TO COVER WHEN READY
Underground Electrical Inspection - Commercial Passed 01/27/2006
Correction
Resolved
01/27/2006
SECONDARY ELECTRICAL SERVICE
Correction
Resolved
01/27/2006
LIGHT POLE BASES + BURIED CONDUIT 6 BASES PREP IN PROGRESS PER DRAWING
Occupancy Inspection - Codes Commercial Not Ready 01/31/2006
Correction
Corrective Action Required
01/31/2006
Receive Fire Department approval
Correction
Corrective Action Required
01/31/2006
Receive Planning & Development Approval
Correction
Corrective Action Required
01/31/2006
Receive Public Works Approval
Correction
Corrective Action Required
01/31/2006
Receive Water Utilities Approval
Correction
Corrective Action Required
01/31/2006
READINESS FOR INSPECTION CALL FOR INSPECTION AFTER PREPARATION IS COMPLETE WORK REQUESTED FOR INSP NOT COMPLETED
Water Service Inspection Passed 01/31/2006
Correction
Resolved
01/31/2006
WATER SERVICE INSTALLATION
Occupancy Inspection - Codes Commercial Failed 02/03/2006
Correction
Corrective Action Required
02/03/2006
Receive Fire Department approval SEE LIST PROVIDED
Correction
Corrective Action Required
02/03/2006
Receive Planning & Development Approval BUSINESS CARD PROVIDED CONTACT TOM SCANNELL PHONE 816-969-7317
Correction
Resolved
02/03/2006
Receive Water Utilities Approval PER BEN HASKAMP 2/3/06
Correction
Resolved
02/03/2006
READINESS FOR INSPECTION
Correction
Partial Correction
02/03/2006
INSTALLATION OF LIGHTED SIGN PER NEC 600-3 SIGN MUST BE LISTED LABELS BEING INSTALLED
Correction
Corrective Action Required
02/03/2006
GAS PIPING AT ROOF SUPPORTS INCOMPLETE
Correction
Corrective Action Required
02/03/2006
LABELING OF ELECTRICAL CIRCUIT BREAKERS IRC E36O6.2. EACH BREAKER MUST BE LABELED. MUST BE LEGIBLE; SPECIFIC. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE" INCOMPLETE SERVICE PANEL SCHEDULE
Correction
Corrective Action Required
02/03/2006
STUCCO EXTERIOR WALL SURFACE AND PENETRATIONS ENSURE FULLY SEALED
Correction
Corrective Action Required
02/03/2006
SUPPORT OF WATER SERVICE ASSEMBLY SECURE TO WALL PER DISCUSSION W/ G.C.
Correction
Corrective Action Required
02/03/2006
COMPLETETION OF DRIVE-THRU CANOPY + WINDOW OVERHANGS IN PROGRESS SUBJECT TO APPROVAL
Correction
Partial Correction
02/03/2006
OCCUPANCY APPROVAL STATUS NO PUBLIC UNTIL TCO ISSUED OK TO SET UP FOR BUSINESS PENDING TCO OK BY PUB WKS
Occupancy Inspection - Codes Commercial Failed 02/07/2006
Correction
Corrective Action Required
02/07/2006
Receive Planning & Development Approval BUSINESS CARD PROVIDED CONTACT TOM SCANNELL PHONE 816-969-7317
Correction
Corrective Action Required
02/07/2006
Receive Public Works Approval CONTACT BILL LYON @ PHONE 816-969-7324
Correction
Resolved
02/07/2006
READINESS FOR INSPECTION
Correction
Resolved
02/07/2006
INSTALLATION OF LIGHTED SIGN UL LABELS INSTALLED PER NEC 600-3
Correction
Resolved
02/07/2006
GAS PIPING AT ROOF SUPPORTS COMPLETE
Correction
Resolved
02/07/2006
LABELING OF ELECTRICAL CIRCUIT BREAKERS SERVICE PANEL SCHEDULE BREAKERS LABELED
Correction
Corrective Action Required
02/07/2006
STUCCO EXTERIOR WALL SURFACE AND PENETRATIONS ENSURE FULLY SEALED
Correction
Resolved
02/07/2006
SUPPORT OF WATER SERVICE ASSEMBLY SECURED TO WALL
Correction
Resolved
02/07/2006
COMPLETETION OF DRIVE-THRU CANOPY + WINDOW OVERHANGS SUBSTANTIALLY COMPLETED
Occupancy Inspection - Codes Commercial Failed 02/10/2006
Correction
Resolved
02/10/2006
Receive Fire Department approval PER JOE DIR 2/9/06
Correction
Corrective Action Required
02/10/2006
Receive Planning & Development Approval BUSINESS CARD PROVIDED CONTACT TOM SCANNELL PHONE 816-969-7317
Correction
Resolved
02/10/2006
Receive Public Works Approval NO ISSUES REMAINING OF RECORD
Correction
Resolved
02/10/2006
INSTALLATION OF LIGHTED SIGN
Correction
Resolved
02/10/2006
GAS PIPING AT ROOF
Correction
Resolved
02/10/2006
LABELING OF ELECTRICAL CIRCUIT BREAKERS
Correction
Resolved
02/10/2006
STUCCO EXTERIOR WALL SURFACE ENSURE ALL PENETRATIONS + JOINTS FULLY SEALED
Correction
Resolved
02/10/2006
SUPPORT OF WATER SERVICE ASSEMBLY
Correction
Resolved
02/10/2006
COMPLETETION OF DRIVE-THRU CANOPY + WINDOW OVERHANGS
Correction
Partial Correction
02/10/2006
OCCUPANCY APPROVAL STATUS SEE TEMPORARY OCCUPANCY
Occupancy Inspection - Codes Commercial Failed 02/28/2006
Occupancy Inspection - Codes Commercial Failed 03/14/2006
Correction
Corrective Action Required
03/14/2006
Receive Planning & Development Approval SEE P&D REPORT DTD 3/7/06
Correction
Resolved
03/14/2006
Receive Public Works Approval
Correction
Resolved
03/14/2006
STUCCO EXTERIOR WALL SURFACE
Occupancy Inspection - Codes Commercial Passed 08/29/2008
Correction
Resolved
08/29/2008
Receive Planning & Development Approval PER BOB MCKAY 8/22/08
Correction
Resolved
08/29/2008
OCCUPANCY APPROVAL STATUS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home