Permit Application Status

B0500318


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0500318
Building Permit - Residential
Certificate of Occupancy
GOODMAN DAVID R
NEW SINGLE FAMILY
HOUSE
03/07/2005
03/10/2005
09/06/2005
07/18/2006
Locations
Contacts
BKS CONSTRUCTION, Address:PO BOX 291  
GOODMAN DAVID R, Address:3429 SW LOIS LN  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 09/05/2005 10/29/2010
Correction

Codes Administration- Bedrooms located in basements shall have at least one operable window or door approved for emergency escape which opens to the exterior. All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet. The net clear openable height shall be 24 inches. The minimum net clear openable width shall be 20 inches. The finished sill height shall not exceed 44 inches above the finished floor. (UBC Section 1204).
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The holder of this permit agrees and understands that the work authorized by this permit shall be performed in accordance with the 2000 International Residential Code as amended by Chapter 7 of the Lee's Summit Code of Ordinances.
Correction

CA - The holder of this permit agrees and understands that only persons authorized per LSCO 7-130 are permitted to perform electrical, plumbing or mechanical work authorized by this permit.
Correction

In a combined effort with both the R-4, and the R-7 School Districts the City of Lee's Summit is working together to educate the development community on a new program, the "Lee's Summit Voluntary Residential Development Surcharge". This is a program, which will help raise capital to build new schools for our community. Brochures are available at the front counter of both the Planning and Development and the Codes Administration departments. You can also find more information on the City of Lee's Summit web site at lees-summit.mo.us. (For more information please contact the Board of Education at 986-2400).
Correction

CA - 2000 IRC 401.3 - Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 inches (152 mm) within the first 10 feet (3048 mm). 2000 IRC, Section 401.3
Correction

CA - 2000 IRC 403.1.6 - Foundation sills and exterior wall sole plates shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet on center. Anchor bolts shall be located within 12 inches from the end of each plate section. Anchor bolts shall be 1/2 inch in diameter and shall extend a minimum of 7 inches into the concrete. A nut and washer shall be tightened on each bolt to the plate. 2000 IRC, Section 403.1.6
Correction

CA - 2000 IRC 403.7.3 - The top of any exterior foundation shall extend above the elevation of the street curb or approved drainage device a minimum of 12" (twelve inches) plus 2%. Alternative elevations are permitted subject to approval of the building official, provided it can be demonstrated that required drainage to the point of discharge and away from the structure is provided at all locations on site. 2000 IRC, Section 403.7.3
Correction

CA - 2000 IRC 405.1 - Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or useable space. Drainage tiles, gravel drains or perforated pipe drainage systems shall be installed at or below the area to be protected and discharge by gravity or mechanical means. Perforated pipe shall be placed upon at least 2 inches of washed gravel or crushed rock and covered with not less than 6 inches of the same material. (2000 IRC, Section 405.1)
Correction

CA - 2000 IRC 703.9 - Foundation walls shall extend above the finished grade a minimum of 4 inches where masonry veneer is used and a minimum of 6 inches elsewhere. (2000 IRC, Section 404.1.6) Exterior Insulation Finish Systems, EFIS, shall terminate not less than 6 inches above finished grade. (2000 IRC, Section 703.9)
Correction

CA - 2000 IRC 314.3 - The minimum headroom in all parts of stairways shall not be less than 6 feet 8 inches measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-122 - Any excavation for foundations and/or footings of buildings and structures shall be backfilled within twenty-eight (28) days from the date of permit issuance unless otherwise approved by the building official.
Correction

CA - LSCO 7-128 (a)1 - Retaining walls which are over 4 feet in height measured from the bottom of the footing to the top of the wall of the wall shall be designed and sealed by a professional engineer or architect registered in the State of Missouri. In addition, the building official may waive the requirements for a permit or engineered drawings for walls over 4 feet in height if it is deemed unnecessary to require such submittals due to the location and type of wall to be installed.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-168 A - Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place before inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94; the concrete need not be on the job.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - LSCO 7-930 - All dwellings shall have a controlled method of water disposal from the roofs that will collect and discharge all roof drainage to the ground at least 3 feet from the foundation walls or to an approved drainage system.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $482.00 $482.00 Paid 03/10/2005
25 Electrical Permit Fee $117.13 $117.13 Paid 03/10/2005
25 Mechanical Permit Fees $53.00 $53.00 Paid 03/10/2005
25 Plumbing Permit Fees $61.00 $61.00 Paid 03/10/2005
84 Water Meters $125.00 $125.00 Paid 03/10/2005
85 Water Taps $2,734.00 $2,734.00 Paid 03/10/2005
89 Sewer Tap Fees $450.00 $450.00 Paid 03/10/2005
Right of Way Permit $35.00 $35.00 Paid 03/10/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 03/15/2005
Correction
Resolved
03/15/2005
NONE None FOOTING AND PADS APPROVED NOTE: BIGGER I-BEAM NEEDED IF BEAM SPAN IS AT ITS CURRENT CONFIGURATION. PLAN CALLS FOR 8" BEAM SPANING 13'6"
Erosion Control Inspection Residential Failed 03/15/2005
Correction
Corrective Action Required
03/15/2005
LSCO 5029 XX Erosion Control EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Water Service Inspection - R Partial 03/30/2005
Correction
Partial Correction
03/30/2005
NONE None APPROVED TO METER
Sewer Service Inspection - R Passed 03/30/2005
Erosion Control Inspection Residential Failed 03/30/2005
Correction
Corrective Action Required
03/30/2005
LSCO 5029 XX Erosion Control EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - Residential Request Complete 3/30/2005 3/30/2005 03/30/2005
Sewer Service Inspection - Residential Request Complete 3/30/2005 3/30/2005 03/30/2005
Water Service Inspection - R Passed 03/31/2005
Correction
Resolved
03/31/2005
NONE None
Erosion Control Inspection Residential Failed 03/31/2005
Correction
Corrective Action Required
03/31/2005
LSCO 5029 XX Erosion Control EROSION CONTROL AND STREET CLEANUP REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Water Service Inspection - Residential Request Complete 3/31/2005 3/31/2005 03/31/2005
Water Service Inspection - Residential Request Complete 3/31/2005 3/31/2005 03/31/2005
Underground Plumbing Inspection - Residential Failed 04/20/2005
Correction
Corrective Action Required
04/20/2005
LSCO 3719 Erosion control REQUESTED INSPECTION DENIED DUE TO LACK OF ADEQUATE EROSION CONTOL
Correction
Corrective Action Required
04/20/2005
R325 Premises Identification (IRC)
Underground Plumbing Inspection - Residential Request Complete 4/19/2005 4/20/2005 04/20/2005
Underground Plumbing Inspection - Residential Request Complete 4/19/2005 4/20/2005 04/20/2005
Piers/Caissons Inspection - Residential Passed 06/24/2005
Correction
Resolved
06/24/2005
NONE None
Electrical Service Inspection Failed 07/29/2005
Correction
Corrective Action Required
07/29/2005
MISC SERVICE ENTRANCE CONDUCTOR SHALL NOT BEND OVER 5 TIMES RADIUS OF CONDUCTOR
Gas Piping Inspection - Residential Passed 07/29/2005
Gas Service Inspection - Residential Failed 07/29/2005
Correction
Corrective Action Required
07/29/2005
M2416.4.1 Gas Test Pressure (IRC) PRESSURIZED GAS PIPING FOR TESTING
All Rough Inspection - Residential Failed 07/29/2005
Correction
Corrective Action Required
07/29/2005
R403.1.6 Foundation Anchor Bolts (IRC) -ANCHOR REQUIRED WITHIN 12" OF END OF WALL PLATE, EVERY 6 FT ON CENTER, AND MIN 2 ANCHORS (AT FRONT GARAGE PORTA WALLS) -TIGHTEN ALL ANCHOR NUTS -ANCHOR DEFICIENCY IN BASEMENT AS WELL
Correction
Corrective Action Required
07/29/2005
MISC WALL TOP PLATE STRAPS REQUIRED -ABOVE KITCHEN WINDOW, AND FRONT BEDROOM
Correction
Corrective Action Required
07/29/2005
MISC NAIL STUD SHOES AT KITCHEN WALL
Correction
Corrective Action Required
07/29/2005
MISC FIREBLOCKING -FIREBLOCK FIREPLACE FROM ATTIC -FIREBLOCK FLOOR PENETRATIONS -FIREBLOCK VERTICAL DEAD SPACES IN BASEMENT FROM WALL AND FUR-DOWN -FIREBLOCK BASEMENT WALL FROM JOIST SPACE
Correction
Corrective Action Required
07/29/2005
E3801.2 Convenience Receptacle Spacing (Walls & Floors) (IRC) KITCHEN/DINING AREA AT CANTILEVERED FLOOR WINDOWS
Correction
Corrective Action Required
07/29/2005
MISC FRAME AND SECURE FIREPLACE
Correction
Corrective Action Required
07/29/2005
MISC OVERFILLED ELECTRICAL BOXES IN 1ST FLOOR WHERE RED-MARKED
Correction
Corrective Action Required
07/29/2005
MISC NAILGUARD REQUIRED AT MASTERBATH SINK WALL
Correction
Corrective Action Required
07/29/2005
P2605.1 Piping Support (IRC) BASEMENT IN ELECTRICAL SERVICE ROOM
Correction
Corrective Action Required
07/29/2005
MISC S-TRAP AT MASTERBATH TUB NOT ALLOWED
Correction
Corrective Action Required
07/29/2005
R317.1 Smoke Alarms (IRC) REQUIRED IMMEDIATELY OUTSIDE BASEMENT BEDROOM
Correction
Corrective Action Required
07/29/2005
MISC CONNECT BASEMENT BATHFAN TO DUCT
Correction
Corrective Action Required
07/29/2005
MISC CLEANOUT ACCESS REQUIRED BY DEAD SPACE BY SHOWER-BASEMENT
Correction
Corrective Action Required
07/29/2005
E3804.7 Electrical in Air Handling Spaces (IRC) INSTALL ELECTRICAL INSIDE FLEXIBLE METALLIC CONDUIT GOING TO LIGHT FIXTURE-LOOK NEAR BASEMENT BOTTOM STAIR LANDING
Correction
Corrective Action Required
07/29/2005
MISC TEXT OKAY TO INSULATE, DO NOT ROCK
All Rough Inspection - Residential Failed 08/02/2005
Correction
Resolved
08/02/2005
R403.1.6 Foundation Anchor Bolts (IRC)
Correction
Resolved
08/02/2005
MISC WALL TOP PLATE STRAPS REQUIRED
Correction
Resolved
08/02/2005
MISC NAIL STUD SHOES AT KITCHEN WALL
Correction
Corrective Action Required
08/02/2005
MISC FIREBLOCKING -FIREBLOCK FIREPLACE FROM ATTIC -FIREBLOCK VERTICAL DEAD SPACES IN BASEMENT FROM WALL AND FUR-DOWN -FIREBLOCK BASEMENT WALL FROM JOIST SPACE
Correction
Corrective Action Required
08/02/2005
E3801.2 Convenience Receptacle Spacing (Walls & Floors) (IRC) KITCHEN/DINING AREA AT CANTILEVERED FLOOR WINDOWS YOU PUT RECEPTICLE IN THE WRONG PLACE FROM THAT I'VE REQUESTED
Correction
Corrective Action Required
08/02/2005
MISC FRAME AND SECURE FIREPLACE
Correction
Corrective Action Required
08/02/2005
MISC OVERFILLED ELECTRICAL BOXES IN 1ST FLOOR WHERE RED-MARKED LOOK AT FRONT DINING RM AT B-VENT CHASE
Correction
Resolved
08/02/2005
MISC NAILGUARD REQUIRED AT MASTERBATH SINK WALL
Correction
Corrective Action Required
08/02/2005
P2605.1 Piping Support (IRC) BASEMENT IN ELECTRICAL SERVICE ROOM
Correction
Resolved
08/02/2005
MISC S-TRAP AT MASTERBATH TUB NOT ALLOWED
Correction
Resolved
08/02/2005
R317.1 Smoke Alarms (IRC)
Correction
Resolved
08/02/2005
MISC CONNECT BASEMENT BATHFAN TO DUCT
Correction
Corrective Action Required
08/02/2005
MISC CLEANOUT ACCESS REQUIRED BY DEAD SPACE BY SHOWER-BASEMENT CHECK ON FINAL
Correction
Corrective Action Required
08/02/2005
E3804.7 Electrical in Air Handling Spaces (IRC) RECONNECT TO LIGHT FIXTURE
Gas Service Inspection - Residential Failed 08/02/2005
Correction
Corrective Action Required
08/02/2005
M2416.4.1 Gas Test Pressure (IRC) PRESSURIZED GAS PIPING FOR TESTING
Electrical Service Inspection Passed 08/02/2005
Correction
Resolved
08/02/2005
MISC SERVICE ENTRANCE CONDUCTOR -APPROVED FOR 1-200 AMP SERVICE RELEASE
Gas Service Inspection - Residential Passed 08/03/2005
Correction
Resolved
08/03/2005
M2416.4.1 Gas Test Pressure (IRC) TESTED AT 20 PSI. APPROVED
Erosion Control Inspection Residential Failed 08/03/2005
Correction
Corrective Action Required
08/03/2005
LSCO 5029 XX Erosion Control EROSION CONTROL AND STREET CLEANUP REQUIRED. PROTECT STORM INLET AT REAR LOT NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 08/05/2005
Correction
Corrective Action Required
08/05/2005
MISC FIREBLOCKING -FIREBLOCK FIREPLACE FROM ATTIC -FIREBLOCK VERTICAL DEAD SPACES IN BASEMENT FROM WALL AND FUR-DOWN -FIREBLOCK BASEMENT WALL FROM JOIST SPACE
Correction
Resolved
08/05/2005
E3801.2 Convenience Receptacle Spacing (Walls & Floors) (IRC)
Correction
Resolved
08/05/2005
MISC FRAME AND SECURE FIREPLACE
Correction
Resolved
08/05/2005
MISC OVERFILLED ELECTRICAL BOXES IN 1ST FLOOR WHERE RED-MARKED
Correction
Corrective Action Required
08/05/2005
P2605.1 Piping Support (IRC) BASEMENT IN ELECTRICAL SERVICE ROOM
Correction
Corrective Action Required
08/05/2005
MISC CLEANOUT ACCESS REQUIRED BY DEAD SPACE BY SHOWER-BASEMENT CHECK ON FINAL
Correction
Resolved
08/05/2005
E3804.7 Electrical in Air Handling Spaces (IRC)
All Rough Inspection - Residential Passed 08/08/2005
Correction
Resolved
08/08/2005
MISC FIREBLOCKING
Correction
Resolved
08/08/2005
P2605.1 Piping Support (IRC) BASEMENT IN ELECTRICAL SERVICE ROOM-CHECK ON FINAL
Correction
Resolved
08/08/2005
MISC CLEANOUT ACCESS REQUIRED BY DEAD SPACE BY SHOWER-BASEMENT CHECK ON FINAL
Correction
Resolved
08/08/2005
MISC TEXT OKAY TO ROCK
Driveway Inspection Passed 02/14/2006
Underground Plumbing Inspection - Residential Failed 06/02/2006
Correction
Corrective Action Required
06/02/2006
R325 Premises Identification (IRC)
Occupancy Inspection - Codes Residential Failed 06/02/2006
Correction
Corrective Action Required
06/02/2006
MISC UNDERGROUND PLUMBING NEVER APPROVED
Correction
Corrective Action Required
06/02/2006
LSCO 3719 Erosion control SOD - GRADING - SEAL AROUND EXTERIOR LIGHT - SEAL EXTERIOR PENETRATIONS - ELECTRICAL WHIP TERMINATION(EAST SIDE) EXTERIOR ISSUES
Correction
Corrective Action Required
06/02/2006
LSCO 7-907 Garage Separation (IRC) UNABLETO DETERMINE -GARAGE HAS FURNITURE ALREADY MOVED INTO IT
Correction
Corrective Action Required
06/02/2006
E3603.2 Kitchen and dining area receptacles (branch circuits) (IRC) REQUIRES 2-20 AMP BREAKERS SERVING COUNTERTOP Kitchen
Correction
Corrective Action Required
06/02/2006
E3304.7 Electrical Equipment Mounting (IRC) INSTALL SPARKRING AT OUTLET SERVING DISHWASHER/DISPOSAL - ALSO REPLACE BROKEN OUTLET Kitchen
Correction
Corrective Action Required
06/02/2006
R317.1 Smoke Alarms (IRC) SMOKE DETECTORS ARE REQUIRED TO BE PLACED W/N DIRECT VICNITY OF BEDROOMS Master Bedroom
Correction
Corrective Action Required
06/02/2006
E4109.3 Hydromassage Bathtub Access (IRC) HYDROTUB MOTOR REQUIRED TO BE READILY ACCESSIBLE Master Bathroom
Correction
Corrective Action Required
06/02/2006
MISC INSTALLATION PER MANUFACTURERS INSTRUCTIONS PROVIDE INSTALLATION INSTRUCTIONS FOR HYDROTUB MOTOR - QUESTIONING INSTALLATION ON BATHROOM PLUGS
Correction
Corrective Action Required
06/02/2006
E3304.11 Identification of Disconnecting Means (IRC) -SERVICE PANEL - LOCKABLE BREAKERS REQUIRED AT COOKTOP AND OVEN -AIR CONDITIONER HAS NOT BEEN INSTALLED -SECURE SERVICE CONDUTOR W/N 12" FORM PANEL -ANY UNFINISHED BASEMENT AREA OVER 70 SQ FT REQUIRES A GFCI OUTLET (BOTH AREAS) Basement
Correction
Corrective Action Required
06/02/2006
MISC THROUGH PENETRATIONS INSTALL ATTIC ACCESS PANEL Master Closet
Correction
Corrective Action Required
06/02/2006
E3304.9 Prevent Physical Damage (IRC) SECURE CONDUIT AT JOIST LEVEL Mechanical Room
Correction
Corrective Action Required
06/02/2006
E3304.9 Prevent Physical Damage (IRC) SECURE WIRING UNDER COUNTERTOP Basement KITCHEN AREA
Correction
Corrective Action Required
06/02/2006
MISC FIXTURE INSTALLATION SEAL AROUND ELECTRICAL FIXTURES TO PREVENT INFILTRATION Deck CEILING
Underslab Plumbing Inspection - Residential Passed 06/22/2006
Underground Plumbing Inspection - Residential Passed 06/22/2006
Correction
Resolved
06/22/2006
LSCO 3719 Erosion control
Correction
Resolved
06/22/2006
R325 Premises Identification (IRC)
Sidewalk Inspection Passed 06/22/2006
Erosion Control Inspection Residential Passed 06/22/2006
Correction
Resolved
06/22/2006
LSCO 5029 XX Erosion Control
Occupancy Inspection - Codes Residential Failed 06/22/2006
Correction
Resolved
06/22/2006
MISC UNDERGROUND PLUMBING NEVER APPROVED
Correction
Corrective Action Required
06/22/2006
LSCO 3719 Erosion control SOD - GRADING - SEAL AROUND EXTERIOR LIGHT - SEAL EXTERIOR PENETRATIONS - ELECTRICAL WHIP TERMINATION(EAST SIDE) EXTERIOR ISSUES
Correction
Resolved
06/22/2006
LSCO 7-907 Garage Separation (IRC)
Correction
Corrective Action Required
06/22/2006
E3603.2 Kitchen and dining area receptacles (branch circuits) (IRC) REQUIRES 2-20 AMP BREAKERS SERVING COUNTERTOP YOU NEED 2 BRANCH CIRCUITS SERVING KITCHEN COUNTERTOP Kitchen
Correction
Resolved
06/22/2006
E3304.7 Electrical Equipment Mounting (IRC)
Correction
Resolved
06/22/2006
R317.1 Smoke Alarms (IRC)
Correction
Resolved
06/22/2006
E4109.3 Hydromassage Bathtub Access (IRC)
Correction
Resolved
06/22/2006
MISC INSTALLATION PER MANUFACTURERS INSTRUCTIONS
Correction
Corrective Action Required
06/22/2006
E3304.11 Identification of Disconnecting Means (IRC) -ANY UNFINISHED BASEMENT REQUIRES A GFCI OUTLET (MECH RM) Basement
Correction
Corrective Action Required
06/22/2006
MISC THROUGH PENETRATIONS ATTIC ACCESS PANEL IN MASTER CLOSET
Correction
Resolved
06/22/2006
E3304.9 Prevent Physical Damage (IRC)
Correction
Resolved
06/22/2006
E3304.9 Prevent Physical Damage (IRC)
Correction
Resolved
06/22/2006
MISC FIXTURE INSTALLATION
Sidewalk Inspection Passed 06/22/2006
Sidewalk Inspection Passed 06/22/2006
Sidewalk Inspection Passed 06/22/2006
Sidewalk Inspection Passed 06/22/2006
Occupancy Inspection - Codes Residential Failed 06/23/2006
Correction
Corrective Action Required
06/23/2006
LSCO 3719 Erosion control SOD - GRADING - SEAL AROUND EXTERIOR LIGHT - SEAL EXTERIOR PENETRATIONS - ELECTRICAL WHIP TERMINATION(EAST SIDE) EXTERIOR ISSUES
Correction
Resolved
06/23/2006
E3603.2 Kitchen and dining area receptacles (branch circuits) (IRC) YOU WILL HAVE MIN 2 BRANCH CIRCUITS SERVING THE COUNTERTOP
Correction
Resolved
06/23/2006
E3304.11 Identification of Disconnecting Means (IRC)
Correction
Resolved
06/23/2006
MISC THROUGH PENETRATIONS
Correction
Corrective Action Required
06/23/2006
MISC CIRCUITS GOING TO EXTERIOR LIGHT POLES -CHANGE OUT WIRING RATED FOR WET CONDITION -ANY EXPOSED WIRE TO EXTERIOR SHALL ALSO BE RATED SUNLIGHT RESISTENT
Occupancy Inspection - Codes Residential Passed 07/17/2006
Correction
Resolved
07/17/2006
LSCO 3719 Erosion control
Correction
Resolved
07/17/2006
MISC CIRCUITS GOING TO EXTERIOR LIGHT POLES
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home