Permit Application Status

B0401295


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0401295
Building Permit - Commercial
Final Completion
HASLEY & JAMESON INVESTMENTS LLC
NEW SHELL BUILDING
WINDSOR COMMONS #1 SHELL
07/08/2004
10/19/2004
04/17/2005
11/30/2005
Locations
Contacts
ARCHITECTURE GRAPHICS & MANAGEMENT, Address:226 SE DOUGLAS ST SUITE 204  
D. L. KIRBY PROPERTIES, Address:826 NE SWANN RD  
HASLEY & JAMESON INVESTMENTS LLC, Address:1332 NE WINDSOR DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/04/2005 10/29/2010
Correction

CA - ANSI A117.1-1998 404.2.7 - Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Such hardware shall be 34 inches minimum and 48 inches maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Correction

Codes Administration - 2003 IBC 1008.1.4 - Floor elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit veritical in 12 units horizontal (2-percent slope).
Correction

Codes Administration - 2003 IBC 1203.2 - Attic spaces. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing members shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain and snow. Blocking and bridging shall be arranged so as not to interfere with the movement of air. A minimum of 1 inch of airspace shall be provided between the insulation and the roof sheathing. The net free ventilation area shall not be less than 1/150 of the area of the space ventilated, with 50 percent of the required ventilation area provided by ventilatiors located in the upper portion of the space to be ventilated at least 3 feet above eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents.
Correction

Codes Administration - 2003 IBC 1209.2 - Attic spaces. An opening not less than 20 inches by 30 inches shall be provided to any attic area having a clear height of over 30 inches. A 30-inch minimum clear headroom in the attic space shall be provided at or above the access opening.
Correction

Codes Administration - 2003 IBC 1704.1.1 - Building permit requirements. The permit applicant shall submit a statement of special inspections prepared by the registered design professional in responsible charge in accordance with Section 106.1 as a condition for permit issuance. This statement shall include a complete list of materials and work requiring special inspections by this section, the inspections to be performed and a list of the individuals, approved agencies or firms intended to be retained for conducting such inspections.
Correction

Codes Administration - 2003 IBC 1704.1.2 - Report Requirement. Special inspectors shall keep records of inspections. The special inspector shall furnish inspection reports to the building official, and to the registered design professional in responsible charge. Reports shall indicate that work inspected was done in conformance to approved construction documents. Discrepancies shall be brought to the immediate attention of the contractor for correction. If the discrepancies are not corrected, the discrepancies shall be brought to the attention of the building official and to the registered design professional in responsible charge prior to the completion of that phase of the work. A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted at a point in time agreed upon by the permit applicant and the building official prior to the start of work.
Correction

Codes Administration - 2003 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as defined in Section 2406.3 shall comply with Sections 2406.1 through 2406.1.5.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Codes Administration - Details have not been provided on the retaining wall.
Correction

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application.
Correction

Codes Administration - The plans show two 2-hour rated assemblies on the floor plan that do not continue to the underside of the roof decking. There are no code requirements for these walls in the codes as tenant separation is not required and the building meets allowable area requirements with setback increases.
Correction

Codes Administration - The Electrical Plan Notes reference KCP&L.
Correction

Codes Administration - A panel schedule is not provided for the house panel.
Correction

Codes Administration - The materials and methods for the electrical installation have not been provided.
Correction

A license agreement for the construction of the retaining wall over the sanitary sewer easement (as shown on the prelimanary development plan dated April 20, 2004) shall be executed between the developer and the City prior to the issuance of the building permit.
Correction

The 15-foot utility easement under Building 1 shall be vacated prior to the issuance of a building permit.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

1003.2.10.1 Fire Department- Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30 480 mm) from the nearest visible exit sign.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $4,502.00 $4,502.00 Paid 10/19/2004
24 BLDG Plan Check Fees $95.00 $95.00 Paid 10/19/2004
25 Electrical Permit Fee $240.00 $240.00 Paid 10/19/2004
25 Plumbing Permit Fees $12.00 $12.00 Paid 10/19/2004
84 Water Meters $125.00 $125.00 Paid 10/19/2004
85 Water Taps $3,418.00 $3,418.00 Paid 10/19/2004
Right of Way Permit $35.00 $35.00 Paid 10/19/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 11/09/2004
Correction
Partial Correction
11/09/2004
GRADE BEAM + INTEGRAL COLUMN FOOTINGS WEST WALL & (E) FROM (1) TO (2); SOUTH WALL COMPLETE; ENSURE RE-BAR COVERAGE OK TO POUR WHEN READY
Footing Inspection - Commercial Partial 11/15/2004
Correction
Partial Correction
11/15/2004
GRADE BEAM + INTEGRAL COLUMN FOOTINGS WEST WALL & (E) FROM (1) TO (2); SOUTH WALL COMPLETE; WEST WALL COMPLETE + ON (4) FROM W END TO (A.7); ENSURE RE-BAR COVERAGE OK TO POUR WHEN READY
Footing Inspection - Commercial Partial 11/22/2004
Correction
Partial Correction
11/22/2004
GRADE BEAM + INTEGRAL COLUMN FOOTINGS WEST WALL & (E) FROM (1) TO (2); SOUTH WALL COMPLETE; WEST WALL COMPLETE + ON (4) FROM W END TO (A.7); ON (D) FROM (4.1) TO NORTH WALL + W 10' OF N WALL; ENSURE RE-BAR COVERAGE OK TO POUR WHEN READY
Footing Inspection - Commercial Partial 12/03/2004
Correction
Partial Correction
12/03/2004
GRADE BEAM + INTEGRAL COLUMN FOOTINGS WEST WALL & (E) FROM (1) TO (2); SOUTH WALL COMPLETE; WEST WALL COMPLETE + ON (4) FROM W END TO (A.7); ON (D) FROM (4.1) TO N WALL + W 10' OF N WALL; E 50' OF N WALL; N 35' OF E WALL; ENSURE RE-BAR COVERAGE OK TO POUR WHEN READY
Footing Inspection - Commercial Partial 12/09/2004
Correction
Partial Correction
12/09/2004
GRADE BEAM + INTEGRAL COLUMN FOOTINGS A/E APPROVAL OF BEARING ON (E) FRM (2.2) TO (4.8); W WALL & (E) FROM (1) TO (2); S WALL COMPLETE; W WALL COMPLETE + ON (4) FRM W END TO (A.7); ON (D) FRM (4.1) TO N WALL + W 10' OF N WALL; E 50' OF N WALL; N 35' OF E WALL ENSURE RE-BAR COVERAGE OK TO POUR CONTINGENT ON
Correction
Partial Correction
12/09/2004
ISOLATED FOOTINGS A; B; C; D OK TO POUR CONTINGENT ON A/E APPROVAL OF DEPTH
Footing Inspection - Commercial Passed 12/10/2004
Correction
Resolved
12/10/2004
GRADE BEAM + INTEGRAL COLUMN FOOTINGS W WALL & (E) FROM (1) TO (2); S WALL COMPLETE; W WALL COMPLETE + ON (4) FRM W END TO (A.7); ON (D) FRM (4.1) TO N WALL + W 10' OF N WALL; E 50' OF N WALL; N 35' OF E WALL; COMPLETE CORNER @ (D)/(4) SEE A/E LETTER DTD 12/9/0 (E) FRM (2.2) TO (4.8);
Correction
Resolved
12/10/2004
ISOLATED FOOTINGS A; B; C; D SEE A/E LETTER DTD 12/9/04 OK TO POUR CONTINGENT ON A/E APPROVAL OF DEPTH
Sewer Service Inspection Not Ready 12/10/2004
Correction
Corrective Action Required
12/10/2004
READINESS FOR INSPECTION LSCO SEC 7-142; IBC 106: NO INSPECTIONS WITHOUT PERMIT DRAWINGS PERMIT DRAWINGS NOT FOUND ON SITE
Sewer Service Inspection - Commercial Request Complete 12/10/2004 12/10/2004 12/10/2004
Water Service Inspection Not Ready 12/13/2004
Correction
Corrective Action Required
12/13/2004
READINESS FOR INSPECTION LSCO SEC 7-142; IBC 106: NO INSPECTIONS WITHOUT PERMIT DRAWINGS PERMIT DRAWINGS NOT FOUND ON SITE
Water Service Inspection - Commercial Request Complete 12/13/2004 12/13/2004 12/13/2004
Underslab Plumbing Inspection - Commercial Not Ready 12/14/2004
Correction
Corrective Action Required
12/14/2004
READINESS FOR INSPECTION LSCO SEC 7-142; IBC 106: NO INSPECTIONS WITHOUT PERMIT DRAWINGS PERMIT DRAWINGS NOT FOUND ON SITE
Underslab Plumbing Inspection - Commercial Passed 12/15/2004
Correction
Resolved
12/15/2004
READINESS FOR INSPECTION
Correction
Resolved
12/15/2004
UNDER-SLAB DWV PIPING OK TO COVER WHEN READY EXCAVATED; LAID; JOINED SLOPED TO DRAIN
Water Service Inspection Passed 12/16/2004
Correction
Resolved
12/16/2004
READINESS FOR INSPECTION PERMIT DRAWINGS NOW ON SITE
Correction
Resolved
12/16/2004
WATER SERVICE INSTALLATION PER DRAWING SHEET 5/8 04-007-2UT FROM BUILDING ENTRY METER/WELL, TAP COMPLETED
Sewer Service Inspection Passed 12/16/2004
Correction
Resolved
12/16/2004
READINESS FOR INSPECTION PERMIT DRAWINGS NOW ON SITE
Correction
Resolved
12/16/2004
SEWER SERVICE INSTALLATION PER DRAWING SHEET 5/8 04-007-2UT FROM BUILDING ENTRY TO CONNECTION AT STUB
Rough Framing Inspection - Commercial Not Ready 02/16/2005
Correction
Corrective Action Required
02/16/2005
READINESS FOR INSPECTION - MANUFACTURED ROOF SYSTEM NOT READY FOR INSPECTION STRUCTURE DESIGN DRAWINGS NOT FOUND ON SITE
Rough Framing Inspection - Commercial Request Complete 2/15/2005 2/16/2005 02/16/2005
Rough Framing Inspection - Commercial Passed 02/17/2005
Correction
Resolved
02/17/2005
READINESS FOR INSPECTION - MANUFACTURED ROOF SYSTEM
Correction
Resolved
02/17/2005
ROOF TRUSS FRAMING SYSTEM BEFORE INSTALLING GWB. OK TO COVER WHEN READY CLOSE ROOF & WALL OPEN'GS
Correction
Resolved
02/17/2005
WALL FRAMING AS PART OF IN-WALL INSPECTION AFTER M/E/P TRADES ARE COMPLETED OK AS ERECTED SUBJECT TO REINSPECTION
Underground Electrical Inspection - Commercial Partial 03/21/2005
Correction
Partial Correction
03/21/2005
UNDERGROUND CONDUIT FOR LOT LIGHTING IN ISLANDS. OK TO COVER WHEN READY O/S CURB @ W PROP LINE + TO POLE LOCATIONS
Sidewalk Inspection Partial 04/04/2005
Sidewalk Inspection Passed 04/05/2005
Electrical Service Inspection Passed 04/07/2005
Correction
Resolved
04/07/2005
HOUSE ELECTRICAL SERVICE ONLY 100 AMPS RELEASE SERVICE
Underground Electrical Inspection - Commercial Partial 06/23/2005
Correction
Partial Correction
06/23/2005
UNDERGROUND CONDUIT FOR LOT LIGHTING IN ISLANDS. OK TO COVER WHEN READY O/S CURB @ W PROP LINE + TO POLE LOCATIONS
Final Inspection - Commercial Failed 06/23/2005
Correction
Partial Correction
06/23/2005
None SHELL APPROVED TO SET UP FOR OCCUPANTS TEMPORARY STATUS APPROVED
Underground Electrical Inspection - Commercial Partial 07/11/2005
Correction
Resolved
07/11/2005
UNDERGROUND CONDUIT FOR LOT LIGHTING
Correction
Partial Correction
07/11/2005
UNDERGROUND CONDUIT TRENCH FOR MONUMENT SIGN LIGHTING TRENCH DEPTH OK
Underground Electrical Inspection - Commercial Passed 07/12/2005
Correction
Resolved
07/12/2005
UNDERGROUND CONDUIT TRENCH FOR MONUMENT SIGN LIGHTING SCHEDULE 80 CONDUIT UTILIZED AS PRECAUTION CONDUIT IN PLACE DEPTH APPROX 18"
Final Inspection - Commercial Failed 09/26/2005
Correction
Resolved
09/26/2005
None
Correction
Corrective Action Required
09/26/2005
EXTERIOR BUILDING WALL LIGHTS NOT YET INSTALLED MUST BE LISTED FOR "WET"
Correction
Corrective Action Required
09/26/2005
Receive Public Works Approval COORDINATE W/ B LYON
Final Inspection - Commercial Failed 10/07/2005
Correction
Corrective Action Required
10/07/2005
EXTERIOR BUILDING WALL LIGHTS NOT YET REPLACED MUST BE LISTED FOR "WET"
Correction
Resolved
10/07/2005
Receive Public Works Approval PER B LYON 10/6/05
Correction
Corrective Action Required
10/07/2005
Receive Planning & Development Approval
Final Inspection - Commercial Passed 11/29/2005
Correction
Resolved
11/29/2005
None CLOSE PERMIT
Correction
Resolved
11/29/2005
EXTERIOR BUILDING WALL LIGHTS IF/WHEN REPLACED MUST BE LISTED FOR "WET"
Correction
Resolved
11/29/2005
Receive Planning & Development Approval PER T SCANNELL 11/28/05
Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home