Summary
B0401260
Building Permit - Commercial
Certificate of Occupancy
ARBOR DEVELOPMENT LLC
NEW COMMERCIAL
CLUBHOUSE
07/01/2004
11/10/2004
05/09/2005
12/14/2005
Locations
Contacts
ARBOR DEVELOPMENT, LLC, Address:9001 N BRITT AV  
HNTB, Address:112 W 9TH STREET  
ARBOR DEVELOPMENT LLC, Address:15885 NW 130TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 12/28/2004 10/29/2010
Correction

A note should be provided indicating the connection of the sump pump shall be made daylight not to the sanitary sewer system.
Correction

CA - 2000 IBC 302.3.1 - Two or more uses. Where the building is occupied for two or more uses not included in the same occupancy, the building or portion thereof shall comply with Section 302.3.2 or 302.3.3 or combinations of thes sections, except that areas of Group H shall be separated from other occupancies in accordance with Section 302.3.3. Areas of Group H-1 shall be in a separate and detached building and structure. Also, see Section 508 for special provisions for buildings containing mixed uses.
Correction

CA - The calculated occupant load is not provided.
Correction

CA - An exit sign is shown at the door to the closing room which is not an egress path.
Correction

CA - Details on the pool construction were not provided.
Correction

CA - LSCO 7-1012 - Steps or ladders. Two (2) or more means of egress in the form of steps or ladders shall be provided for all swimming pools. At least one (1) such means of egress shall be locaed on a side of the pool at both the deep end and shallow end of the pool. Treads of steps and ladders shall be constructed of nonslip material and at least three (3) inches wide for their fill length. Steps and ladders shall have a handrail on both sides.
Correction

Fire Department-Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department- Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30 480 mm) from the nearest visible exit sign.
Correction

Fire Department- Indicate the type of pool sanitizer to be used.
Correction

Arbor Walk Stage One - The City shall issue no temporary or final Certificates of Occupancy for any of the Stage 1 Development until the City has issued a Certificate of Substantial Completion for all of the Stage 1 road Improvements. Only the Stage 1 Development may be occupied after the Stage 1 Road Improvements are constructed, until adequate road improvements are constructed to serve the Stage 2 Development pursuant to Section 2.B below. (Arbor Walk Development Agreement, Section 2.A.)
Correction

Arbor Walk Stage One - The Developer agrees to construct a twelve inch(12") water line between Ward Road and Pryor Road, along Arborwalk Boulevard. The parties agree to enter into a separate agreement which shall provide a reimbursement to the Developer by the City in exchange for upsizing the Water Line from an eight inch (8") line to a twelve inch (12") line. The City shall issue no temporary or final Certificates of Occupancy for any of the Stage 1 Development until the City has accepted the Water Line. (Arbor Walk Development Agreement, Section 5.)
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

CA - 2000 IBC 1003.2.2.5 - Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

CA - 2000 IBC 1003.3.3.11 - Handrails. Stairways shall have handrails on each side. Handrails shall be adequate in strength and attachment in accordance with Section 1607.7.
Correction

CA - 2000 IBC 1003.2.11.2 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency system shall automatically illuminate all of the follow areas: 1. Exit access corridors, passageways, and aisles in rooms and spaces which require two or more means of egress. 2. Exit access corridors and exit stairways located in buildings required to have two or more exits. 3. Interior exit discharge elements, as permitted in Section 1006.1, in buildings required to have two or more exits. 4. The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits.
Correction

Fire Department; Fire apparatus access roads shall have an unobstructed width of not less than 20 feet except for approved security gates in accordance with Section 503.6, and an unobstructed vertical clearance of not less than 13 feet 6 inches.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the code official.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - 2000 IMC 403.3 - Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and the occupant load or other perameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less then the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

CA - 2000 IMC 304.8 - Clearances from grade. Equipment and appliances installed at grade level shall be supported on a level concrete slab or other approved material extending above adjoining grade or shall be suspended a minimum of 6 inches (152 mm) aboave adjoining grade.
Correction

CA - 2000 IPC 312.1 - Required tests. The permit holder shall make the applicable test prescribed in Sections 312.2 through 312.9 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain if the pressure has reached all parts of the system. Note: Testing of the plumbing system is not required to be witnessed by the Codes Administration Staff with the exception of gas piping.
Correction

CA - LSCO Chapter 7, Section 7-1018 - Every swimming pool shall be equipped with one (1) or more throwing ring buoys not more than fifteen (15) inches in diameter and having sixty (60) feet of three-sixteenths-inch manila line attached, and one (1) or more light but strong poles with blunt ends and not less than twelve (12) feet in length, for making reach assists or rescues.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

CA - 1999 NEC 250-104(b) - Metal gas piping. Each aboveground portion of a gas piping system upstream from the equipment shutoff valve shall be electrically continuous and bonded to the grounding electrode system.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $2,291.00 $2,291.00 Paid 11/10/2004
24 BLDG Plan Check Fees $58.15 $58.15 Paid 11/10/2004
25 Electrical Permit Fee $243.07 $243.07 Paid 11/10/2004
25 Mechanical Permit Fees $115.00 $115.00 Paid 11/10/2004
25 Plumbing Permit Fees $80.00 $80.00 Paid 11/10/2004
89 Sewer Tap Fees $390.00 $390.00 Paid 11/10/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection Passed 12/29/2004
All Rough Inspection - Commercial Failed 02/11/2005
Correction
Corrective Action Required
02/11/2005
SECURELY FASTEN NM EVERY 4.5 FT OC SECURE NM WITHIN 8" OF FURNACE BOXES-NORTH FURNACE
Correction
Corrective Action Required
02/11/2005
COMMON B-VENT IN ATTIC AND CONNECTORS -CONNECTORS IN ATTIC SPACE REQUIRED TO BE B-VENT TYPE -COMMON B-VENT HORIZONTAL OFFSET LENGTH IN ATTIC SHALL NOT EXCEED 1.5 FT PER INCH OF VENT DIAMETER.
Correction
Corrective Action Required
02/11/2005
CLothes Dryer Exhaust Duct Length Limitation (IRC) 35 FT WITH 2 ELBOWS
Correction
Corrective Action Required
02/11/2005
PROTECT WIRES NEAR ATTIC ACCESS WIRES RUNNING ACROSS CEILING JOISTS WITHIN 6 FT OF ACCESS OPENING SHALL BE PROTECTED
Correction
Corrective Action Required
02/11/2005
Fireblocking (IRC) -FIREBLOCK ALL FLOOR/CEILING PENETRATIONS, IE PLUMBING TRAPS, HVAC, OPENINGS, ETC. -FIREBLOCK AROUND CHIMNEY AND COMPLETE CHIMNEY
Correction
Corrective Action Required
02/11/2005
DERATE WIRES IN RACEWAY FROM SERVICE EQUIPMENT.
Correction
Corrective Action Required
02/11/2005
DRIP LEGS FOR GAS PIPING TO FURNACES
Correction
Corrective Action Required
02/11/2005
TEXT OKAY TO INSULATE, DO NOT ROCK
All Rough Inspection - Commercial Failed 02/17/2005
Correction
Resolved
02/17/2005
SECURELY FASTEN NM EVERY 4.5 FT OC
Correction
Resolved
02/17/2005
COMMON B-VENT IN ATTIC AND CONNECTORS
Correction
Resolved
02/17/2005
PROTECT WIRES NEAR ATTIC ACCESS
Correction
Resolved
02/17/2005
Fireblocking (IRC)
Correction
Resolved
02/17/2005
DERATE WIRES IN RACEWAY
Correction
Resolved
02/17/2005
DRIP LEGS FOR GAS PIPING TO FURNACES
Correction
Resolved
02/17/2005
TEXT OKAY TO ROCK
Electrical Service Inspection Failed 02/24/2005
Correction
Partial Correction
02/24/2005
None 700 AMP SERVICE 1- 400 AMP ,1- 200 AMP ,1- 100 AMP NEED TO BOND GAS PIPING PER PLANS RECALL WHEN COMPLETE
Erosion Control Inspection Residential Failed 04/08/2005
Correction
Corrective Action Required
04/08/2005
Erosion Control
Electrical Service Inspection Passed 04/25/2005
Correction
Resolved
04/25/2005
None 700 AMP SERVICE 1- 400 AMP ,1- 200 AMP ,1- 100 AMP SERVICE APPROVED FOR RELEASE
All Rough Inspection - Commercial Passed 06/01/2005
Correction
Resolved
06/01/2005
CLothes Dryer Exhaust Duct Length Limitation (IRC)
Occupancy Inspection - Codes Commercial Failed 06/01/2005
Correction
Corrective Action Required
06/01/2005
SOD
Correction
Corrective Action Required
06/01/2005
PROVIDE LAWN SPRINKLER PERMIT
Correction
Corrective Action Required
06/01/2005
SECURE ALL A/C UNITS FLNC WITHIN 12" OF A/C DISCONNECTS
Correction
Corrective Action Required
06/01/2005
NORTH EXTERIOR GFCI NOT WORKING
Correction
Corrective Action Required
06/01/2005
COMPLETE ALL EXTERIOR LIGHTING
Correction
Corrective Action Required
06/01/2005
GAS SERVICE NOT CONNECTED
Correction
Corrective Action Required
06/01/2005
INSTALL BUILDING SEWER CLEANOUT PLUG
Correction
Corrective Action Required
06/01/2005
POOL -COMPLETE POOL, FENCE, AND ALL ASSOCIATED EQIUPMENTS, HANDRAIL
Correction
Corrective Action Required
06/01/2005
GROUT GAS PIPING AT FIREBOX FIREPLACE
Correction
Corrective Action Required
06/01/2005
SERVICE PANEL -IDENTIFY ALL CIRCUIT BREAKERS -PROVIDE PROPER SIZE BREAKERS FOR ALL A/C UNITS PER LABELS -INSTALL 30 AMP BREAKER AND HANDLE TIE FOR DRYER
Correction
Corrective Action Required
06/01/2005
FINAL -FIRE DEPARTMENT APPROVAL REQUIRED
Occupancy Inspection - Codes Commercial Failed 06/03/2005
Correction
Corrective Action Required
06/03/2005
FINAL -FIRE DEPARTMENT APPROVAL REQUIRED -POST ADDRESS AND INSTALL 2 FIRE EXTINGUISHER PER FIRE -COMPLETE DEVELOPMENT AND APPROVAL FROM PUBLIC WORKS BEFORE FULL CO IS ISSUED
Occupancy Inspection - Codes Commercial Failed 06/07/2005
Correction
Resolved
06/07/2005
SOD
Correction
Resolved
06/07/2005
SECURE ALL A/C UNITS FLNC WITHIN 12" OF A/C DISCONNECTS
Correction
Resolved
06/07/2005
NORTH EXTERIOR GFCI NOT WORKING
Correction
Resolved
06/07/2005
GAS SERVICE NOT CONNECTED
Correction
Resolved
06/07/2005
INSTALL BUILDING SEWER CLEANOUT PLUG
Correction
Resolved
06/07/2005
GROUT GAS PIPING AT FIREBOX
Correction
Resolved
06/07/2005
SERVICE PANEL
Correction
Partial Correction
06/07/2005
FINAL -POST ADDRESS AND INSTALL 2 FIRE EXTINGUISHER PER FIRE-OK -COMPLETE DEVELOPMENT AND APPROVAL FROM PUBLIC WORKS BEFORE FULL CO IS ISSUED -STRIPES FOR HANDICAP-OK -APPROVED FOR TCO
Occupancy Inspection - Codes Commercial Failed 09/01/2005
Correction
Resolved
09/01/2005
PROVIDE LAWN SPRINKLER PERMIT
Correction
Resolved
09/01/2005
COMPLETE ALL EXTERIOR LIGHTING
Correction
Resolved
09/01/2005
POOL
Correction
Partial Correction
09/01/2005
FINAL -POST ADDRESS AND INSTALL 2 FIRE EXTINGUISHER PER FIRE-OK -COMPLETE DEVELOPMENT AND APPROVAL FROM PUBLIC WORKS BEFORE FULL CO IS ISSUED -STRIPES FOR HANDICAP-OK -APPROVED FOR TCO
Occupancy Inspection - Codes Commercial Passed 12/13/2005
Correction
Resolved
12/13/2005
FINAL
Erosion Control Inspection Residential Passed 12/13/2005
Correction
Resolved
12/13/2005
Erosion Control
Gas Service Inspection - Commercial Passed 12/13/2005
Correction
Resolved
12/13/2005
None GAS SERVICE APPROVED IN FOUNDATION AND UNDERSLAB PERMIT
Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home