Summary
B0400909
Building Permit - Commercial
Certificate of Occupancy
UNION BANK
NEW COMMERCIAL
NEW BANK WITH DRIVE THRU
05/18/2004
07/23/2004
01/19/2005
05/05/2005
Locations
Contacts
A L HUBER, Address:10770 EL MONTE  
UNION BANK, Address:9300 BLUE RIDGE BLVD  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 11/14/2004 10/29/2010
Correction

CA - ANSI A117.1-1998 404.2.7 - Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Such hardware shall be 34 inches minimum and 48 inches maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Correction

Fire Department-Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

CA - Some of the detail indications found in the Construction Notes on Sheet C100 are incorrect.
Correction

CA - Information on the translucent panel skylights was not provided at the time of permit application.
Correction

A note should be provided indicating a Reduce Pressure Zone (RPZ) principal backflow prevention device will be placed inside the building on the domestic water service line rather than the double check (DCV) that is indicated at the water service entrance.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

CA - 2000 IBC 1109.1 - Required accessible elements shall be identified by the International Symbol of Accessiblity at the locations listed in Section 1109.1. 1. Not applicable as the zoning ordinance is more restrictive. 2. Accessible passenger loading zones. 3. Accessible areas of refuge required by Section 1103.2.13.5. 4. Accessible rooms where multi single-user toilet or bathing rooms are clustered at a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the check-out aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting, and locker rooms where not all such rooms are accessible.
Correction

CA - 2000 IBC 1209.2 - Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture.
Correction

CA - 2000 IBC 1209.1 - In other than dwelling units, toilet and bathing room floors shall have a smooth, hard, nonabsorbent surface that extends upward onto the walls at least 6 inches.
Correction

CA - 2000 IBC 1108.4 - Where kitchen, kitchenettes and wet bars are provided in accessible spaces or rooms, they shall be accessible in accordance with ICC/ANSI A117.1.
Correction

CA - 2000 IBC 1003.3.1.4 - Floor Elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal.
Correction

CA - 2000 IBC 1003.3.1.6 - Thresholds. Thresholds at doorways shall not exceed 0.75 inch in height for sliding doors serving dwelling units or 0.5 inch for other doors. Raised thresholds and floor level changes greater then 0.25 inch at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope).
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - 2000 IMC 403.3 - Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and the occupant load or other perameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less then the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

CA - 2000 IMC 304.8 - Clearances from grade. Equipment and appliances installed at grade level shall be supported on a level concrete slab or other approved material extending above adjoining grade or shall be suspended a minimum of 6 inches (152 mm) aboave adjoining grade.
Correction

CA - 2000 IPC 708.3.2 - Building sewers shall be provided with cleanouts located not more than 100 feet apart measured fron the upstream entrance of the cleanout. For building sewers 8 inches and larger, manholes shall be provided and located at each change in direction and at intervals of not more than 400 feet of developed length of the drainage piping.
Correction

CA - 2000 IPC 708.3.5 - Building drain and building sewer junction. There shall be a cleanout near the junction of the building drain and the building sewer. The cleanout shall be either inside or outside the building wall and shall be brought up to the finished ground level or the basement floor level. An approved two-way cleanout is allowed to be used at this location to serve as a required cleanout for both the building drain and building sewer. The cleanout at the junction of the building drain and building sewer shall not be required if the cleanout on a 3-inch (76 mm) or larger diameter soil stack is located within a developed length of 10 feet (3048 mm) of the building drain and building sewer connection.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $2,702.00 $2,702.00 Paid 07/23/2004
24 BLDG Plan Check Fees $65.00 $65.00 Paid 07/23/2004
25 Electrical Permit Fee $152.75 $152.75 Paid 07/23/2004
25 Mechanical Permit Fees $70.50 $70.50 Paid 07/23/2004
25 Plumbing Permit Fees $38.00 $38.00 Paid 07/23/2004
84 Water Meters $200.00 $200.00 Paid 07/23/2004
85 Water Taps $5,468.00 $5,468.00 Paid 07/23/2004
89 Sewer Tap Fees $180.00 $180.00 Paid 07/23/2004
Right of Way Permit $35.00 $35.00 Paid 07/23/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection Partial 08/11/2004
Correction
Partial Correction
08/11/2004
INITIAL PARTIAL WATER SERVICE INSTALLATION OK TO COVER WHEN READY FROM BUILDING ENTRY TO TAP LOCATION
Water Service Inspection - Commercial Request Complete 8/11/2004 8/11/2004 08/11/2004
Sewer Service Inspection Passed 08/12/2004
Correction
Resolved
08/12/2004
SEWER SERVICE INSTALLATION TO CONNECTION AT STUB FROM 5' OUTSIDE BUILDING ENTRY
Sewer Service Inspection - Commercial Request Complete 8/12/2004 8/12/2004 08/12/2004
Water Service Inspection Passed 08/13/2004
Correction
Resolved
08/13/2004
INITIAL PARTIAL WATER SERVICE INSTALLATION
Correction
Resolved
08/13/2004
FINAL PARTIAL WATER SERVICE INSTALLATION OK TO COVER WHEN READY METER/WELL INSTALLED TAP COMPLETED
Underground Plumbing Inspection - Commercial Partial 08/13/2004
Correction
Partial Correction
08/13/2004
STORM SEWER PIPING & BOXES FROM D.P. 14 PIPE LAID N 84'; ENSURE DESIGN SLOPE OK TO COVER WHEN READY
Sewer Service Inspection - Commercial Request Complete 8/13/2004 8/13/2004 08/13/2004
Water Service Inspection - Commercial Request Complete 8/13/2004 8/13/2004 08/13/2004
Electrical Service Inspection Partial 08/20/2004
Correction
Partial Correction
08/20/2004
TEMPORARY ELECTRICAL SERVICE INSTALLATION RELEASE TEMPORARY SERVICE
Footing Inspection - Commercial Partial 09/03/2004
Correction
Partial Correction
09/03/2004
None GRADE BEAM WITH 6 PADS WITHIN GRADE BEAM APPROVED. 3 CONTINUOUS # 5 AND VERT. # 4 48 INCHES O.C. OKAY TO POUR WHEN READY.
Rough Electrical Inspection - Commercial Passed 09/03/2004
Correction
Resolved
09/03/2004
None 2 CONCRETE ENCASED GROUNDING ELECTRODES APPROVED. 1 @ SOUTH SECTION OF GRADE BEAM AND 1 @ EAST END OF GRADE BEAM.
Footing Inspection - Commercial Passed 09/09/2004
Correction
Resolved
09/09/2004
None PERIMETER GRADE BEAM
Correction
Resolved
09/09/2004
ISOLATED FOOTINGS TYPE F3 & F6 OKAY TO POUR WHEN READY
Underslab Plumbing Inspection - Commercial Passed 09/13/2004
Underslab Electrical Inspection - Commercial Passed 09/15/2004
Correction
Resolved
09/15/2004
UNDER-FLOOR ELECTRICAL CONDUIT MATERIAL & WORKMANSHIP OK TO COVER WHEN READY
Underground Electrical Inspection - Commercial Request Complete 9/14/2004 9/15/2004 09/15/2004
Underground Plumbing Inspection - Commercial Partial 09/23/2004
Correction
Partial Correction
09/23/2004
STORM SEWER PIPING & BOXES FROM D.P. 14 PIPE LAID N 84'; LINE 4 STA 0+00 TO NE BLDG CORNER; ENSURE DESIGN SLOPE OK TO COVER WHEN READY
Underground Plumbing Inspection - Commercial Partial 09/24/2004
Correction
Partial Correction
09/24/2004
STORM SEWER PIPING & BOXES FROM D.P. 14 PIPE LAID TO SW BLDG CORNER, THEN N TO DOWNSPOUT LOCATIONS; LINE 4 STA 0+00 TO NE BLDG CORNER; ENSURE DESIGN SLOPE OK TO COVER WHEN READY
Underground Plumbing Inspection - Commercial Partial 09/27/2004
Correction
Resolved
09/27/2004
STORM SEWER PIPING & BOXES FROM D.P. 14 PIPE LAID TO SW BLDG CORNER, THEN N TO DOWNSPOUT LOCATIONS; LINE 4 STA 0+00 TO NE BLDG CORNER; ENSURE DESIGN SLOPE OK TO COVER WHEN READY
Correction
Partial Correction
09/27/2004
STORM SEWER BALANCE OF ROOF DRAIN TO EAST (SOUTH AND NORTH ELEVATIONS) TO DOWNSPOUT LOCATIONS OK TO COVER
Underground Electrical Inspection - Commercial Passed 09/28/2004
Correction
Resolved
09/28/2004
SECONDARY SERVICE CONDUIT OK TO COVER WHEN READY FROM BUILDING ENTRANCE TO TRANSFORMER LOCATION
Underground Electrical Inspection - Commercial Passed 10/15/2004
Correction
Resolved
10/15/2004
SECONDARY SERVICE CONDUIT
Correction
Resolved
10/15/2004
U.G. CONDUIT TO DRIVE-THROUGH STATIONS OK TO COVER WHEN READY
Underground Electrical Inspection - Commercial Passed 12/01/2004
Correction
Resolved
12/01/2004
U.G. CONDUIT TO DRIVE-THROUGH STATIONS
Correction
Resolved
12/01/2004
LIGHT POLE BASES PER DRWG ME201 OK TO POUR WHEN READY EXCEPT 2 DELETED NEXT TO DOUGLAS STREET
Underground Electrical Inspection - Commercial Passed 12/13/2004
Correction
Resolved
12/13/2004
LIGHT POLE BASES PER DRWG ME201
Correction
Resolved
12/13/2004
LOT LIGHT GROUNDING OK TO COVER WHEN READY RODS + CONDUCTORS 9 POLE BASES
Underground Electrical Inspection - Commercial Request Complete 12/13/2004 12/13/2004 12/13/2004
All Rough Inspection - Commercial Partial 12/29/2004
Correction
Partial Correction
12/29/2004
None FRAMING,ELECT, ROUGH PLUMBING WALLS ONLY APPROVED. IN WALLS
Electrical Service Inspection Passed 12/29/2004
Correction
Resolved
12/29/2004
TEMPORARY ELECTRICAL SERVICE INSTALLATION RELEASE TEMPORARY SERVICE
Correction
Resolved
12/29/2004
None 400 AMP SERVICE APPROVED - RELEASE
Erosion Control Inspection Residential Passed 12/29/2004
Above Ceiling Inspection Partial 01/27/2005
Correction
Partial Correction
01/27/2005
HARD CEILING AREAS TEMP ELECTRICAL WIRING BEFORE COVERING. OK TO COVER WHEN READY COMPLETE REMOVAL OF ALL
All Rough Inspection - Commercial Passed 02/24/2005
Correction
Resolved
02/24/2005
None
Above Ceiling Inspection Passed 02/24/2005
Correction
Resolved
02/24/2005
HARD CEILING AREAS
Correction
Resolved
02/24/2005
ABOVE-CEILING SYSTEMS OK TO COVER WHEN READY
Occupancy Inspection - Codes Commercial Failed 03/09/2005
Correction
Resolved
03/09/2005
Receive Fire Department approval PER N ULLERY 3/9/05
Correction
Corrective Action Required
03/09/2005
Receive Planning & Development Approval COORDNATE W/ T SCANNELL LIST & PH# PROVIDED
Correction
Corrective Action Required
03/09/2005
Receive Public Works Approval COORDINATE W/ BILL LYON 969-7324
Correction
Resolved
03/09/2005
Receive Water Utilities Approval NO ISSUES PRESENTED
Correction
Corrective Action Required
03/09/2005
EXTERIOR WALL TIGHTNESS E.G., WINDOW HEADS; AWNING SUPPORTS; AROUND PNEUMATIC TUBE ENTRY;... CAULKING/SEALANTS TO BE COMPLETED
Correction
Corrective Action Required
03/09/2005
ELECTRICAL 2ND RIGHT OF BREAK ROOM SINK NOT GFCI PROTECTED NOT SINGLE RECEPT
Correction
Corrective Action Required
03/09/2005
WATER CLOSET IN MENS RR FLUSH HANDLE NOT ON FREE SIDE OF TANK
Correction
Corrective Action Required
03/09/2005
ELECT J.B.'S IN ROOM 104 KNOCKOUTS NOT CLOSED
Correction
Corrective Action Required
03/09/2005
WATER LINE RIGHT OF PRESSURE REGULATOR NOT SECURED TO SUPPORT
Correction
Partial Correction
03/09/2005
OCCUPANCY APPROVAL STATUS SEE TEMPORARY OCCUPANCY
Correction
Corrective Action Required
03/09/2005
AWNINGS @ WEST WINDOWS SUBJECT TO APPROVAL WHEN INSTALLED
Occupancy Inspection - Codes Commercial Passed 05/04/2005
Correction
Resolved
05/04/2005
Receive Planning & Development Approval PER T SCANNELL 5/2/05
Correction
Resolved
05/04/2005
Receive Public Works Approval PER BILL LYON 5/3/05
Correction
Resolved
05/04/2005
EXTERIOR WALL TIGHTNESS
Correction
Resolved
05/04/2005
ELECTRICAL 2ND RIGHT OF BREAK ROOM SINK
Correction
Resolved
05/04/2005
WATER CLOSET IN MENS RR
Correction
Resolved
05/04/2005
ELECT J.B.'S IN ROOM 104
Correction
Resolved
05/04/2005
WATER LINE RIGHT OF PRESSURE REGULATOR
Correction
Resolved
05/04/2005
OCCUPANCY APPROVAL STATUS
Correction
Resolved
05/04/2005
AWNINGS @ WEST WINDOWS
Documents & Images
Date Uploaded File Type Document Name
07/31/2017 Union Bank Douglas Station
07/31/2017 Union Bank Douglas Station Re-inspection
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home