Permit Application Status

B0400120


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0400120
Building Permit - Commercial
Certificate of Occupancy
DOUGLAS STATION SHOPPING CENTER LLC
NEW TENANT FINISH
TENANT FINISH
01/22/2004
02/23/2004
08/21/2004
04/21/2004
Locations
Contacts
AFC HEATING AND COOLING, Address:629 NE PILGRAM WAY  
CLEAR LINE PLUMBING, Address:1348 SE PRINCETON DR  
ROZIER ELECTRIC, INC., Address:1608 SW JEFFERSON  
BUMGARNER ASSOCIATES CONSTRUCTION MANAGEMENT, Address:4210 SW CLIPPER CR  
DOUGLAS STATION SHOPPING CENTER LLC, Address:1725 NE RICE RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/20/2004 10/29/2010
Correction

CA - ANSI A117.1-1998 404.2.7 - Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Such hardware shall be 34 inches minimum and 48 inches maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Correction

Fire Department- the occupant load shall be posted ina conspicuous location.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm notification appliances. 3. Alarm control and trouble signaling equipment. 4. Manufacturers, model numbers and listing informa- tion for equipment, devices and materials. 5. Details of ceiling height and construction. 6. The interface of fire safety control functions.
Correction

CA - Structural information was not provided for the installation of the new mechanical equipment.
Correction

CA - I am unable to locate any informtion on the dryer vent.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - For the Health Department inspection contact Bob Thomas with the Jackson County Public Works Department at 816-881-4530. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - 2000 IBC 1109.1 - Required accessible elements shall be identified by the International Symbol of Accessiblity at the locations listed in Section 1109.1. 1. Not applicable as the zoning ordinance is more restrictive. 2. Accessible passenger loading zones. 3. Accessible areas of refuge required by Section 1103.2.13.5. 4. Accessible rooms where multi single-user toilet or bathing rooms are clustered at a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the check-out aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting, and locker rooms where not all such rooms are accessible.
Correction

CA - 2000 IBC 1209.2 - Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. The plans and specifications shall bear a State of Missouri licensed engineers seal. This includes fire sprinkler systems, grease hood and duct suppression systems as well as other fire suppression system.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - 2000 IMC 602.2.1 - Except as required by Section 602.2.1.1 through 602.2.1.4, materials exposed within plenumbs shall be noncombustible or shall have a flame spread index of not more than 25 and a smoke-developed index of not more than 50 when tested in accordance with ASTM E 84.
Correction

CA - 2000 IMC 506.3.13.3 - Termination location. Exhaust outlets shall be located not less than 10 feet (3048 mm) horizontally from parts of the same or contiguous buildings, adjacent property lines and air intake openings into any building and shall be located not less than 10 feet (3048 mm) above the adjoining grade level.
Correction

CA - 2000 IPC 312.1 - Required tests. The permit holder shall make the applicable test prescribed in Sections 312.2 through 312.9 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain if the pressure has reached all parts of the system. Note: Testing of the plumbing system is not required to be witnessed by the Codes Administration Staff with the exception of gas piping.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

CA - 1999 NEC 250-104(b) - Metal gas piping. Each aboveground portion of a gas piping system upstream from the equipment shutoff valve shall be electrically continuous and bonded to the grounding electrode system.
Correction

P & D - All exterior mechanical equipment, whether roof mounted or ground mounted, shall be screened from view from off the property. The appearance of screens shall be coordinated with the building to maintain a unified appearance.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $332.00 $332.00 Paid 02/11/2004
24 BLDG Plan Check Fees $25.50 $25.50 Paid 02/11/2004
25 Electrical Permit Fee $89.79 $89.79 Paid 02/11/2004
25 Mechanical Permit Fees $37.00 $37.00 Paid 02/11/2004
25 Plumbing Permit Fees $49.00 $49.00 Paid 02/11/2004
89 Sewer Tap Fees $210.00 $210.00 Paid 02/11/2004
24 BLDG Permit Fees ($332.00) ($332.00) $0.00 N/A
24 BLDG Plan Check Fees ($25.50) ($25.50) $0.00 N/A
25 Electrical Permit Fee ($89.79) ($89.79) $0.00 N/A
25 Mechanical Permit Fees ($37.00) ($37.00) $0.00 N/A
25 Plumbing Permit Fees ($49.00) ($49.00) $0.00 N/A
89 Sewer Tap Fees ($210.00) ($210.00) $0.00 N/A
24 BLDG Permit Fees $332.00 $332.00 Paid 02/23/2004
24 BLDG Plan Check Fees $25.50 $25.50 Paid 02/23/2004
25 Electrical Permit Fee $89.79 $89.79 Paid 02/23/2004
25 Mechanical Permit Fees $37.00 $37.00 Paid 02/23/2004
25 Plumbing Permit Fees $49.00 $49.00 Paid 02/23/2004
89 Sewer Tap Fees $210.00 $210.00 Paid 02/23/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - Commercial Request Complete 2/26/2004 2/26/2004 02/26/2004
Underground Plumbing Inspection - Commercial Partial 02/27/2004
Correction
Partial Correction
02/27/2004
RISER FROM EXSTG SAN SEWER LINE OK TO COVER WHEN READY
Underslab Plumbing Inspection - Commercial Passed 03/02/2004
Correction
Resolved
03/02/2004
VISUAL INSP + PRESSURE TEST 5 PSI FOR 15 MIN OK TO COVER WHEN READY
Underground Plumbing Inspection - Commercial Passed 03/04/2004
Correction
Resolved
03/04/2004
RISER FROM EXSTG SAN SEWER LINE OK TO COVER WHEN READY
Underslab Plumbing Inspection - Commercial Passed 03/04/2004
Correction
Resolved
03/04/2004
VISUAL INSP + PRESSURE TEST NOTED A/E LETTER DTD 2/27/04 RE TWO VARIATIONS FROM PERMIT PRINTS 5 PSI FOR 15 MIN OK TO COVER WHEN READY
Electrical Service Inspection Passed 03/08/2004
Correction
Resolved
03/08/2004
ELECTRICAL SERVICE INSTALLATION 200 AMP RELEASE SERVICE
All Rough Inspection - Commercial Failed 03/16/2004
Correction
Resolved
03/16/2004
IN-WALL ELECTRICAL SYSTEMS ROUGH
Correction
Partial Correction
03/16/2004
IN-WALL PLUMBING SYSTEMS ROUGH FROM FACE OF STUD / PLATE / TRACK IPC 305.8 COMPLETE SHIELD PLATING COPPER & PVC PIPE <1-1/2"
All Rough Inspection - Commercial Passed 03/18/2004
Correction
Resolved
03/18/2004
IN-WALL PLUMBING SYSTEMS ROUGH
Correction
Resolved
03/18/2004
IN-WALL SYSTEMS ROUGH OK TO COVER WHEN READY
Above Ceiling Inspection Failed 04/06/2004
Correction
Corrective Action Required
04/06/2004
SPRINKLER DROPS INCOMPLETE
Correction
Corrective Action Required
04/06/2004
LIGHT FIXTURE INSTALLATION INCOMPLETE
Correction
Corrective Action Required
04/06/2004
VENTING & DUCTWORK INCOMPLETE
Correction
Corrective Action Required
04/06/2004
FRAMING ABOVE PRIVATE DINING 102 APPEARS TO BE COMBUSTIBLE
Correction
Corrective Action Required
04/06/2004
ABANDONED PARTITION BRACE NEAR REAR DOORS USE OR REMOVE
Correction
Corrective Action Required
04/06/2004
CEILING TILE PLACEMENT OK ONLY AT CAN LIGHTS & SPRINKLER DROPS
Above Ceiling Inspection Partial 04/08/2004
Correction
Resolved
04/08/2004
SPRINKLER DROPS
Correction
Resolved
04/08/2004
LIGHT FIXTURE INSTALLATION
Correction
Resolved
04/08/2004
VENTING & DUCTWORK
Correction
Resolved
04/08/2004
FRAMING ABOVE PRIVATE DINING 102
Correction
Resolved
04/08/2004
ABANDONED PARTITION BRACE NEAR REAR DOORS
Correction
Resolved
04/08/2004
CEILING TILE PLACEMENT
Correction
Corrective Action Required
04/08/2004
PVC PLUMBING STACK @ RESTROOMS NOT ISOLATED FROM CEILING RA PLENUM
Occupancy Inspection - Codes Commercial Failed 04/19/2004
Correction
Resolved
04/19/2004
Receive Fire Department approval PLACE SIGNAGE PER N ULLERY 4/19/04
Correction
Partial Correction
04/19/2004
Receive Water Utilities Approval TO J WALTERS CONFIRM BACKFLOW TEST RESULTS ARE SUBMITED
Correction
Corrective Action Required
04/19/2004
Receive Planning & Development Approval JB WILL CHECK W/ LSP&D
Occupancy Inspection - Codes Commercial Passed 04/20/2004
Correction
Resolved
04/20/2004
Receive Water Utilities Approval PER J WALTERS 4/20/04
Correction
Resolved
04/20/2004
Receive Planning & Development Approval PER T SCANNELL 4/20/04
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents