Summary
B0400047
Building Permit - Commercial
Certificate of Occupancy
CALIFORNIA TIGERS LLC
CHANGE OF TENANT
US $2.75 CLEANERS
01/08/2004
01/29/2004
07/27/2004
02/26/2004
Locations
Contacts
ABELN AND ASSOCIATES ARCHITECTS, Address:11827 W 112TH ST  
MALNAR CONSTRUCTION, Address:4665 W 188TH STREET  
CALIFORNIA TIGERS LLC, Address:4400 SHAWNEE MISSION PKWY STE 209  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/06/2004 10/29/2010
Correction

CA - The occupancy type shown on the plans as an M. Pick-up and delivery stations are classified as a B occupancy in Section 304.
Correction

CA - The calculated occupant loads are incorrect.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - Each layer of fire-resistive assemblies shall be inspected and approved prior to the application of additional layers or finishes. All firestopping of penetrations and required dampers shall be inspected and approved prior to concealing.
Correction

CA - 2000 IBC 1209.2 - Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture.
Correction

CA - 2000 IBC 1108.12.3 - Point of sales and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, the accessible counters shall also be dispersed.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $17.00 $17.00 Paid 01/29/2004
24 BLDG Plan Check Fees $3.25 $3.25 Paid 01/29/2004
25 Electrical Permit Fee $30.00 $30.00 Paid 01/29/2004
25 Mechanical Permit Fees $19.50 $19.50 Paid 01/29/2004
25 Plumbing Permit Fees $21.00 $21.00 Paid 01/29/2004
89 Sewer Tap Fees $60.00 $60.00 Paid 01/29/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Electrical Inspection - Commercial Partial 02/02/2004
Correction
Partial Correction
02/02/2004
None CENTER DIVIDING WALL
Underslab Plumbing Inspection - Commercial Passed 02/02/2004
Correction
Resolved
02/02/2004
None
Rough Electrical Inspection - Commercial Passed 02/04/2004
Correction
Resolved
02/04/2004
None
Gas Service Inspection - Commercial Passed 02/04/2004
Correction
Resolved
02/04/2004
None HELD 10 PSI. RELEASE METER
Gas Piping Inspection - Commercial Passed 02/04/2004
Correction
Resolved
02/04/2004
None
Rough Framing Inspection - Commercial Partial 02/04/2004
Correction
Partial Correction
02/04/2004
None BATHROOM WALL ON CLEANER SIDE NOT COMPLETE
Rough Plumbing Inspection - Commercial Partial 02/04/2004
Correction
Partial Correction
02/04/2004
None ABOVE CEILING NOT FINISHED
Rough Mechanical Inspection - Commercial Failed 02/04/2004
Correction
Corrective Action Required
02/04/2004
None APPLIANCES NOT INSTALLED.
Above Ceiling Inspection Partial 02/17/2004
Correction
Partial Correction
02/17/2004
Duct COMPLETE DUCT OKAY TO HANG TILE - LEAVE TILE OUT FOR DUCT INSPECTION
Occupancy Inspection - Codes Commercial Passed 02/20/2004
Correction
Resolved
02/20/2004
None SCOPE OF WORK COMPLETED AND APPROVED FOR COMPLIANCE TO CITY ORDINANCES ELECTRICAL WIRING, LIGHTING WHIPS, AND DUCT HAVE NUMEROUS VIOLATIONS. BUILDING OWNER/TENANT TO AFFECT REPAIRS
Rough Mechanical Inspection - Commercial Passed 02/20/2004
Correction
Resolved
02/20/2004
None
Above Ceiling Inspection Passed 02/23/2004
Correction
Resolved
02/23/2004
Duct This was completed as I was leaving the site.
Rough Framing Inspection - Commercial Passed 02/23/2004
Correction
Resolved
02/23/2004
None See B040077
Rough Plumbing Inspection - Commercial Passed 02/23/2004
Correction
Resolved
02/23/2004
None Cleaner's side of tenant fnish B040077
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home