Permit Application Status

B0302466


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0302466
Building Permit - Commercial
Certificate of Occupancy
CP DEER BROOK PLAZA LLC
ALTERATION COMMERCIAL
PIZZA HUT INTERIOR REMODEL
12/29/2003
02/10/2004
08/08/2004
08/24/2004
Locations
Contacts
GEHRING CONSTRUCTION INC, Address:3816 W LINEBAUGH SUITE 103  
CP DEER BROOK PLAZA LLC, Address:3400 COLLEGE BLVD STE 195  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 06/26/2004 10/29/2010
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department- The hood suppression system shall be tied to the building fire alarm system (sprinkler) IFC 904.3.5.
Correction

Fire Department - Contact the Fire Department at 816-969-7424 to schedule the hood test.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - For the Health Department inspection contact Bob Thomas with the Jackson County Public Works Department at 816-881-4530. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $107.00 $107.00 Paid 02/10/2004
24 BLDG Plan Check Fees $10.75 $10.75 Paid 02/10/2004
25 Electrical Permit Fee $30.00 $30.00 Paid 02/10/2004
25 Mechanical Permit Fees $21.50 $21.50 Paid 02/10/2004
25 Plumbing Permit Fees $13.00 $13.00 Paid 02/10/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Failed 03/08/2004
Correction
Corrective Action Required
03/08/2004
See Text FRAMING, PLUMBING OR ELECTRICAL UNABLE TO INSPECT. ALREADY COVERED. 3/8" VICE 5/8" GYP BOARD INSTALLED. REMOVE GYP BOARD & SHEATING TO ALLOW FOR ALL ROUGH INSPECTION
Hood/Duct Inspection Partial 03/08/2004
Correction
Partial Correction
03/08/2004
None VISUAL INSPECTION OF WELDS. MINIMUM OF 1" CLEARANCE AT ROOF.
Gas Piping Inspection - Commercial Failed 03/08/2004
Correction
Corrective Action Required
03/08/2004
Gas Piping Support (IRC) INSUFFICIENT
Gas Service Inspection - Commercial Passed 03/08/2004
Correction
Resolved
03/08/2004
None 14 PSI. RELEASE METER
All Rough Inspection - Commercial Failed 03/09/2004
Correction
Corrective Action Required
03/09/2004
See Text OPEN J-BOXES - ABOVE CEILING OKAY TO ROCK
Gas Service Inspection - Commercial Passed 03/09/2004
Gas Piping Inspection - Commercial Passed 03/09/2004
Correction
Resolved
03/09/2004
Gas Piping Support (IRC)
Underslab Plumbing Inspection - Commercial Passed 03/09/2004
Correction
Resolved
03/09/2004
None
Hood/Duct Inspection Passed 03/09/2004
Correction
Resolved
03/09/2004
None
Occupancy Inspection - Codes Commercial Failed 03/16/2004
Correction
Corrective Action Required
03/16/2004
Receive Fire Department approval RECEIVE UNDER SEPARATE COVER
Correction
Resolved
03/16/2004
Receive Water Utilities Approval
Correction
Corrective Action Required
03/16/2004
Open J-Box
All Rough Inspection - Commercial Passed 03/16/2004
Correction
Resolved
03/16/2004
See Text
Occupancy Inspection - Codes Commercial Failed 03/17/2004
Correction
Resolved
03/17/2004
Open J-Box
Occupancy Inspection - Codes Commercial Passed 08/23/2004
Correction
Resolved
08/23/2004
Receive Fire Department approval
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home