Summary
B0302236
Building Permit - Commercial
Certificate of Occupancy
DOUGLAS STATION SHOPPING CENTER LLC
NEW TENANT FINISH
TENANT FINISH, RESTAURANT
11/11/2003
01/14/2004
07/12/2004
06/22/2004
Locations
Contacts
DOMINIC COFFEE, Address:301 NW CENTRAL SUITE H  
TOMPKINS ARCHITECTS, Address:612 NW KAY DRIVE  
DOUGLAS STATION SHOPPING CENTER LLC, Address:1725 NE RICE RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 05/09/2004 10/29/2010
Correction

A double check valve assembly is required on the ice machine service line.
Correction

JC - A three compartment sink is required in all commercial kitchens but only a two compartment is shown on the plans.
Correction

CA - Placement of required exit signage and emergency lighting is subject to onsite inspection.
Correction

CA - Details on the Type II hood and exhaust have not been provided.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department- The occupant load shall be posted.
Correction

Fire Department- The exterior door from the kitchen that is blocked on the interior shallbe marked "NOT AN EXIT" on the exterior side.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - For the Health Department inspection contact Bob Thomas with the Jackson County Public Works Department at 816-881-4530. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - 2000 IBC 1003.2.2.5 - Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

CA - 2000 IBC 1108.12.3 - Point of sales and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, the accessible counters shall also be dispersed.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. The plans and specifications shall bear a State of Missouri licensed engineers seal. This includes fire sprinkler systems, grease hood and duct suppression systems as well as other fire suppression system.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm-initiating and notification appli- ances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing informa- tion for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - 2000 IMC 403.3 - Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and the occupant load or other perameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less then the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

CA - 2000 IMC 602.2.1 - Except as required by Section 602.2.1.1 through 602.2.1.4, materials exposed within plenumbs shall be noncombustible or shall have a flame spread index of not more than 25 and a smoke-developed index of not more than 50 when tested in accordance with ASTM E 84.
Correction

CA - 2000 IPC 802.2 - All indirect waste piping shall discharge through an air gap or air break into a waste receptor or standpipe. Waste receptors and standpipes shall be trapped and vented and shall connect to the building drainage system. All indirect waste piping that exceeds 2 feet in developed length measured horizontally, or 4 feet in total developed length, shall be trapped.
Correction

CA - 2000 IPC 312.1 - Required tests. The permit holder shall make the applicable test prescribed in Sections 312.2 through 312.9 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain if the pressure has reached all parts of the system. Note: Testing of the plumbing system is not required to be witnessed by the Codes Administration Staff with the exception of gas piping.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

CA - 1999 NEC 250-104(b) - Metal gas piping. Each aboveground portion of a gas piping system upstream from the equipment shutoff valve shall be electrically continuous and bonded to the grounding electrode system.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $146.00 $146.00 Paid 01/14/2004
24 BLDG Plan Check Fees $14.00 $14.00 Paid 01/14/2004
25 Electrical Permit Fee $160.60 $160.60 Paid 01/14/2004
25 Mechanical Permit Fees $30.50 $30.50 Paid 01/14/2004
25 Plumbing Permit Fees $63.00 $63.00 Paid 01/14/2004
89 Sewer Tap Fees $300.00 $300.00 Paid 01/14/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 02/09/2004
Correction
Resolved
02/09/2004
UNDER-SLAB DWV & WATER PIPING OK TO COVER WHEN READY. PRESSURE TEST PER DRAWING NOTE TO BE WITNESSED WHEN TOP ROUGH IS INSPECTED AS PART OF IN-WALL INSPECTION. EXCAVATED; LAID; JOINED DWV SLOPED TO DRAIN
Electrical Service Inspection Not Ready 02/10/2004
Correction
Corrective Action Required
02/10/2004
IDENTIFICATION @ METERING SWITCHBOARD MUST BE INSPECTED & APPROVED. NOT READY FOR INSPECTION UNTIL POSITION IS IDENTIFIED. NOT FOUND FOR 1198 TERMINATED FEEDERS
Electrical Service Inspection Passed 02/13/2004
Correction
Resolved
02/13/2004
IDENTIFICATION @ METERING SWITCHBOARD
Correction
Resolved
02/13/2004
RELEASE SERVICE
Rough Plumbing Inspection - Commercial Partial 02/23/2004
Correction
Partial Correction
02/23/2004
PROTECTION OF COPPER & PVC PIPING IPC 305.8; IRC P2603: INSTALL SHIELD PLATES AT STUDS & TRACKS. PRESSURE TESTS OK < 1-1/2" FROM FACE OF STUD / TRACK
All Rough Inspection - Commercial Passed 03/08/2004
Correction
Resolved
03/08/2004
IN-WALL SYSTEMS ROUGH OK TO COVER WHEN READY
Rough Plumbing Inspection - Commercial Passed 03/08/2004
Correction
Resolved
03/08/2004
PROTECTION OF COPPER & PVC PIPING
Gas Piping Inspection - Commercial Passed 03/08/2004
Correction
Resolved
03/08/2004
TWO FEEDER DROPS FROM ROOF AT >= 10 PSI FOR 10 MIN. VISUAL OK TEST PRESSURE LEVEL HELD STEADY
Above Ceiling Inspection Not Ready 04/05/2004
Correction
Corrective Action Required
04/05/2004
READINESS FOR INSPECTION IBC 109.1, 109.5: NOT READY PROPERTY LOCKED INTERIOR NOT ACCESSIBLE
Above Ceiling Inspection Failed 04/20/2004
Correction
Resolved
04/20/2004
READINESS FOR INSPECTION
Correction
Corrective Action Required
04/20/2004
REAR AREA WITH FLOOR COATING DOORWAY BLOCKED, PRESUMABLY BY FLOOR FINISH CONTRACTOR NOT ACCESSIBLE NOT INSPECTED
Correction
Corrective Action Required
04/20/2004
WOOD MATERIAL ABOVE MEETING ROOM COMBUSTIBLE - NOT REMOVED
Correction
Corrective Action Required
04/20/2004
INSTALLATION OF MC ELECTRICAL CABLE NEC 300-11 & 334-10: ONLY EXCEPTION: FIXTURE WHIPS NOT IN EXCESS OF 6` NOT SECURELY FASTENED WITHIN 12" OF BOXES
Above Ceiling Inspection Failed 04/21/2004
Correction
Partial Correction
04/21/2004
REAR AREA WITH FLOOR COATING SEE MC CABLE ISSUE
Correction
Resolved
04/21/2004
WOOD MATERIAL ABOVE MEETING ROOM
Above Ceiling Inspection Passed 04/23/2004
Correction
Resolved
04/23/2004
REAR AREA WITH FLOOR COATING
Correction
Resolved
04/23/2004
INSTALLATION OF MC ELECTRICAL CABLE
Occupancy Inspection - Codes Commercial Failed 06/17/2004
Correction
Corrective Action Required
06/17/2004
Receive Water Utilities Approval
Correction
Corrective Action Required
06/17/2004
Receive Fire Department approval
Correction
Corrective Action Required
06/17/2004
SUPPORT OF STEEL GAS PIPING SECURE TO STRUCTURE WATER HEATER INCOMPLETE
Correction
Partial Correction
06/17/2004
OCCUPANCY STATUS UNTIL APPROVED OK FOR STAFF ONLY NO PUBLIC ACCESS
Occupancy Inspection - Codes Commercial Passed 06/21/2004
Correction
Resolved
06/21/2004
Receive Water Utilities Approval PER J WALTERS 6/21/04
Correction
Resolved
06/21/2004
Receive Fire Department approval PER N ULLERY 6/21/04
Correction
Resolved
06/21/2004
SUPPORT OF STEEL GAS PIPING
Correction
Resolved
06/21/2004
OCCUPANCY STATUS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home