Permit Application Status

B0301863


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0301863
Building Permit - Residential
Certificate of Occupancy
STABLES JOHN R & MARIAN H
NEW SINGLE FAMILY
HOUSE
09/16/2003
09/19/2003
03/17/2004
04/19/2005
Locations
Contacts
BKS CONSTRUCTION, Address:PO BOX 291  
STABLES JOHN R & MARIAN H, Address:3401 SW LOIS LN  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 03/14/2004 10/29/2010
Correction

Codes Administration- Bedrooms located in basements shall have at least one operable window or door approved for emergency escape which opens to the exterior. All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet. The net clear openable height shall be 24 inches. The minimum net clear openable width shall be 20 inches. The finished sill height shall not exceed 44 inches above the finished floor. (UBC Section 1204).
Correction

Codes Administration - If decks are not shown on plot plans submitted at the time of permit application for the structure, and decks are proposed to be installed prior to occupancy, a separate approval and permit is required prior to construction of such deck(s).
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The holder of this permit agrees and understands that the work authorized by this permit shall be performed in accordance with the 2000 International Residential Code as amended by Chapter 7 of the Lee's Summit Code of Ordinances.
Correction

CA - The holder of this permit agrees and understands that only persons authorized per LSCO 7-130 are permitted to perform electrical, plumbing or mechanical work authorized by this permit.
Correction

In a combined effort with both the R-4, and the R-7 School Districts the City of Lee's Summit is working together to educate the development community on a new program, the "Lee's Summit Voluntary Residential Development Surcharge". This is a program, which will help raise capital to build new schools for our community. Brochures are available at the front counter of both the Planning and Development and the Codes Administration departments. You can also find more information on the City of Lee's Summit web site at lees-summit.mo.us. (For more information please contact the Board of Education at 986-2400).
Correction

CA - 2000 IRC 401.3 - Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 inches (152 mm) within the first 10 feet (3048 mm). 2000 IRC, Section 401.3
Correction

CA - 2000 IRC 403.1.6 - Foundation sills and exterior wall sole plates shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet on center. Anchor bolts shall be located within 12 inches from the end of each plate section. Anchor bolts shall be 1/2 inch in diameter and shall extend a minimum of 7 inches into the concrete. A nut and washer shall be tightened on each bolt to the plate. 2000 IRC, Section 403.1.6
Correction

CA - 2000 IRC 403.7.3 - The top of any exterior foundation shall extend above the elevation of the street curb or approved drainage device a minimum of 12" (twelve inches) plus 2%. Alternative elevations are permitted subject to approval of the building official, provided it can be demonstrated that required drainage to the point of discharge and away from the structure is provided at all locations on site. 2000 IRC, Section 403.7.3
Correction

CA - 2000 IRC 405.1 - Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or useable space. Drainage tiles, gravel drains or perforated pipe drainage systems shall be installed at or below the area to be protected and discharge by gravity or mechanical means. Perforated pipe shall be placed upon at least 2 inches of washed gravel or crushed rock and covered with not less than 6 inches of the same material. (2000 IRC, Section 405.1)
Correction

CA - 2000 IRC 703.9 - Foundation walls shall extend above the finished grade a minimum of 4 inches where masonry veneer is used and a minimum of 6 inches elsewhere. (2000 IRC, Section 404.1.6) Exterior Insulation Finish Systems, EFIS, shall terminate not less than 6 inches above finished grade. (2000 IRC, Section 703.9)
Correction

CA - 2000 IRC 314.3 - The minimum headroom in all parts of stairways shall not be less than 6 feet 8 inches measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-122 - Any excavation for foundations and/or footings of buildings and structures shall be backfilled within twenty-eight (28) days from the date of permit issuance unless otherwise approved by the building official.
Correction

CA - LSCO 7-128 (a)1 - Retaining walls which are over 4 feet in height measured from the bottom of the footing to the top of the wall of the wall shall be designed and sealed by a professional engineer or architect registered in the State of Missouri. In addition, the building official may waive the requirements for a permit or engineered drawings for walls over 4 feet in height if it is deemed unnecessary to require such submittals due to the location and type of wall to be installed.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-168 A - Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place before inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94; the concrete need not be on the job.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - LSCO 7-930 - All dwellings shall have a controlled method of water disposal from the roofs that will collect and discharge all roof drainage to the ground at least 3 feet from the foundation walls or to an approved drainage system.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $446.00 $446.00 Paid 09/19/2003
25 Electrical Permit Fee $89.16 $89.16 Paid 09/19/2003
25 Mechanical Permit Fees $50.00 $50.00 Paid 09/19/2003
25 Plumbing Permit Fees $36.00 $36.00 Paid 09/19/2003
84 Water Meters $125.00 $125.00 Paid 09/19/2003
85 Water Taps $2,734.00 $2,734.00 Paid 09/19/2003
89 Sewer Tap Fees $300.00 $300.00 Paid 09/19/2003
Right of Way Permit $35.00 $35.00 Paid 09/19/2003
24 BLDG Permit Fees $12.00 $12.00 Paid 07/29/2004
25 Electrical Permit Fee $30.10 $30.10 Paid 07/29/2004
25 Mechanical Permit Fees $4.50 $4.50 Paid 07/29/2004
25 Plumbing Permit Fees $6.00 $6.00 Paid 07/29/2004
89 Sewer Tap Fees $90.00 $90.00 Paid 07/29/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 09/29/2003
Correction
Corrective Action Required
09/29/2003
LSCO 5029 XX Erosion Control EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Correction
Corrective Action Required
09/29/2003
LSCO5029XX2 Tracking Mud, Debris STREET CLEAN UP IS REQUIRED. STREET CLEAN UP SHALL BE PERFORMED IMMEDIATELY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL STREET CLEAN UP HAS BEEN COMPLETED.
Footing Inspection - Residential Passed 09/29/2003
Correction
Resolved
09/29/2003
NONE None
Erosion Control Inspection Residential Failed 10/13/2003
Correction
Corrective Action Required
10/13/2003
LSCO 5029 XX Erosion Control EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Correction
Corrective Action Required
10/13/2003
LSCO5029XX2 Tracking Mud, Debris STREET CLEAN UP IS REQUIRED. STREET CLEAN UP SHALL BE PERFORMED IMMEDIATELY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL STREET CLEAN UP HAS BEEN COMPLETED.
Underslab Plumbing Inspection - Residential Failed 10/13/2003
Correction
Corrective Action Required
10/13/2003
LSCO 3719 Erosion control REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Passed 10/15/2003
Correction
Resolved
10/15/2003
LSCO 3719 Erosion control
All Rough Inspection - Residential Failed 11/24/2003
Correction
Corrective Action Required
11/24/2003
MISC Flashing DO NOT POUR CONCRETE AGAINST WOOD OR SIDING WITHOUT PROTECTING. Front Porch Stoop
Correction
Corrective Action Required
11/24/2003
R602.8 Fireblocking (IRC) SEAL ALL BTWEEN FLOOR PENETRATIONS AND OPENINGS TO ATTIC
Correction
Corrective Action Required
11/24/2003
MISC NO TOP PLATE REQUIRED TO HAVE DOUBLE TOP PLATE. 1ST FLOOR BACK BEARING WALL
Correction
Corrective Action Required
11/24/2003
R502.6 Bearing (Joist/Beam Girder) (IRC) FILL BEAM POCKETS FOR FULL BEARING OF BEAMS Basement
Correction
Partial Correction
11/24/2003
R502.3 Floor Joist Span (IRC) IF HAARDWOOD OR TILE INSTALLED ON FIRST FLOOR, ENGINEER REPORT WILL BE REQUIRED.
Correction
Corrective Action Required
11/24/2003
MISC Vent Plumbing ALL STUB PLUMBING REQUIRED TO BE VENTED. Basement
Correction
Corrective Action Required
11/24/2003
R802.3 Roof Framing (Details) (IRC) SUPPORT HIP/ RIDGE INTERSECTION NEXT TO LANDING OVER NW BEDROOM.
Correction
Corrective Action Required
11/24/2003
MISC Protect Plumbing Laundry Room PVC PIPE INTERIOR
Correction
Corrective Action Required
11/24/2003
MISC BELOW OKAY TO INSULATE, DO NOT ROCK
Electrical Service Inspection Failed 11/24/2003
Correction
Corrective Action Required
11/24/2003
E3510.1 Grounding Electrode Installation (IRC) NOT INSTALLED
All Rough Inspection - Residential Failed 12/02/2003
Correction
Resolved
12/02/2003
R602.8 Fireblocking (IRC)
Correction
Resolved
12/02/2003
MISC NO TOP PLATE 1ST FLOOR BACK BEARING WALL
Correction
Corrective Action Required
12/02/2003
R502.6 Bearing (Joist/Beam Girder) (IRC) FILL BEAM POCKETS FOR FULL BEARING OF BEAMS Basement SE CORNER
Correction
Partial Correction
12/02/2003
R502.3 Floor Joist Span (IRC) IF HAARDWOOD OR TILE INSTALLED ON FIRST FLOOR, ENGINEER REPORT WILL BE REQUIRED.
Correction
Resolved
12/02/2003
MISC Vent Plumbing Basement
Correction
Resolved
12/02/2003
R802.3 Roof Framing (Details) (IRC)
Correction
Resolved
12/02/2003
MISC Protect Plumbing Laundry Room PVC PIPE INTERIOR
Correction
Corrective Action Required
12/02/2003
MISC BELOW OKAY TO INSULATE, OKAY TO ROCK
Erosion Control Inspection Residential Failed 12/24/2003
Correction
Corrective Action Required
12/24/2003
LSCO5029XX2 Tracking Mud, Debris STREET CLEAN UP IS REQUIRED. STREET CLEAN UP SHALL BE PERFORMED IMMEDIATELY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL STREET CLEAN UP HAS BEEN COMPLETED.
Correction
Corrective Action Required
12/24/2003
LSCO 5029 XX Erosion Control PPROVIDE EROSION CONTROL/NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS IN PLACE
Gas Service Inspection - Residential Passed 12/24/2003
Correction
Resolved
12/24/2003
NONE None
Sewer Service Inspection - R Passed 01/08/2004
Correction
Resolved
01/08/2004
NONE None
Erosion Control Inspection Residential Failed 01/08/2004
Correction
Corrective Action Required
01/08/2004
LSCO 5029 XX Erosion Control RESTORE EROSION CONTROL AND CLEAN STREET/NO FURTHER INSPECTIONS UNTIL COMPLETED
Sewer Service Inspection - Residential Request Complete 1/8/2004 1/8/2004 01/08/2004
Water Service Inspection - R Passed 01/09/2004
Correction
Resolved
01/09/2004
NONE None
Water Service Inspection - Residential Request Complete 1/9/2004 1/9/2004 01/09/2004
Piers/Caissons Inspection - Residential Passed 03/17/2004
Correction
Resolved
03/17/2004
NONE None CLEAN OUT ANY WATER
Electrical Service Inspection Failed 03/17/2004
Correction
Corrective Action Required
03/17/2004
Misc- No Access Provided NO ACCESS
Electrical Service Inspection Passed 03/18/2004
Correction
Resolved
03/18/2004
E3510.1 Grounding Electrode Installation (IRC)
Correction
Resolved
03/18/2004
Misc- No Access Provided
Driveway Inspection Passed 03/22/2004
Correction
Resolved
03/22/2004
NONE None
Driveway Inspection Passed 03/22/2004
All Rough Inspection - Residential Failed 07/13/2004
Correction
Resolved
07/13/2004
R502.3 Floor Joist Span (IRC) Approved per engineer report.
Sidewalk Inspection Passed 07/29/2004
Correction
Resolved
07/29/2004
NONE None
Sidewalk Inspection Passed 07/29/2004
All Rough Inspection - Residential Failed 07/30/2004
Correction
Corrective Action Required
07/30/2004
MISC STREET CLEANUP
Gas Piping Inspection - Residential Passed 10/21/2004
Erosion Control Inspection Residential Passed 10/21/2004
Correction
Resolved
10/21/2004
LSCO 5029 XX Erosion Control
Correction
Resolved
10/21/2004
LSCO5029XX2 Tracking Mud, Debris
Correction
Resolved
10/21/2004
LSCO 5029 XX Erosion Control
Correction
Resolved
10/21/2004
LSCO 5029 XX Erosion Control
Lawn Sprinkler Final Passed 10/21/2004
All Rough Inspection - Residential Passed 10/21/2004
Correction
Resolved
10/21/2004
MISC Flashing Front Porch Stoop
Correction
Resolved
10/21/2004
R502.6 Bearing (Joist/Beam Girder) (IRC) Basement SE CORNER
Correction
Resolved
10/21/2004
MISC BELOW
Correction
Resolved
10/21/2004
MISC STREET CLEANUP
Occupancy Inspection - Codes Residential Failed 10/21/2004
Correction
Corrective Action Required
10/21/2004
R401.3 Grading (IRC) -PROVIDE GRADING TOWARD STREET BETWEEN OF HOUSES -PROVIDE 36" SPLASHBLOCKS THROUGHOUT
Correction
Corrective Action Required
10/21/2004
MISC FRONT EXTERIOR GFCI OUTLET REQUIRED
Correction
Corrective Action Required
10/21/2004
MISC MASTERBATH SINK GFCI NOT TRIPPING
Correction
Corrective Action Required
10/21/2004
MISC FACE PLATE FOR HYDROTUB GFCI OUTLET REQUIRED
Correction
Corrective Action Required
10/21/2004
MISC MICROWAVE SPARK RING REQUIRED
Correction
Corrective Action Required
10/21/2004
LSCO 7-914 Handrails (IRC) ATTIC ACCESS PANEL REQUIRED
Correction
Corrective Action Required
10/21/2004
LSCO 7-914 Handrails (IRC) SECURE HANDRAIL TO WALL-200 LB STRENGTH (STAIR TO BASEMENT)
Correction
Corrective Action Required
10/21/2004
MISC UPDATE PERMIT TO INCLUDE FINISHED BASEMENT
Correction
Corrective Action Required
10/21/2004
MISC COMBUSTION AIR MIN 158 SQU. INCH OF FREE AREA FOR EACH OPENING-MECH. ROOM
Correction
Corrective Action Required
10/21/2004
MISC GROUT BEAM POCKET UNDER I BEAM-BASEMENT
Correction
Corrective Action Required
10/21/2004
MISC PROVIDE PERMANET LADDER FROM ESCAPE WINDOW WELL BASEMENT BEDROOM
Correction
Corrective Action Required
10/21/2004
MISC TEXT -DO NOT OCCUPY -SPACE UNDER STAIR NEED TO BE COVERED W/ SHEETROCK IF THE SPACE BY IT IS TO BE FINISHED
Occupancy Inspection - Codes Residential Failed 10/28/2004
Correction
Corrective Action Required
10/28/2004
R401.3 Grading (IRC) -PROVIDE GRADING TOWARD STREET BETWEEN OF HOUSES. WHERE IS THE SUMP PUMP DISCHARGE OUTLET? GRADE AWAY FROM HOUSE DOESN'T SEEM GOOD. -PROVIDE 36" SPLASHBLOCKS THROUGHOUT
Correction
Resolved
10/28/2004
MISC FRONT EXTERIOR GFCI OUTLET REQUIRED
Correction
Resolved
10/28/2004
MISC MASTERBATH SINK GFCI NOT TRIPPING
Correction
Resolved
10/28/2004
MISC FACE PLATE FOR HYDROTUB GFCI OUTLET REQUIRED
Correction
Resolved
10/28/2004
MISC MICROWAVE SPARK RING REQUIRED
Correction
Resolved
10/28/2004
LSCO 7-914 Handrails (IRC)
Correction
Resolved
10/28/2004
LSCO 7-914 Handrails (IRC)
Correction
Resolved
10/28/2004
MISC UPDATE PERMIT TO INCLUDE FINISHED BASEMENT
Correction
Resolved
10/28/2004
MISC COMBUSTION AIR
Correction
Resolved
10/28/2004
MISC GROUT BEAM POCKET UNDER I BEAM-BASEMENT
Correction
Resolved
10/28/2004
MISC PROVIDE PERMANET LADDER FROM ESCAPE WINDOW WELL
Correction
Resolved
10/28/2004
MISC TEXT -30 DAYS TCO APPROVED
Occupancy Inspection - Codes Residential Passed 04/18/2005
Correction
Resolved
04/18/2005
R401.3 Grading (IRC)
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home