B0301403


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0301403
Building Permit - Commercial
Certificate of Occupancy
I-470 FRONTAGE INVESTORS LLC
CHANGE OF TENANT
PREFERRED WINDOWS TENANT FINISH
07/18/2003
07/31/2003
01/27/2004
09/05/2003
Locations
Contacts
KESSINGER HUNTER AND COMPANY LC, Address:2600 GRAND #700  
I-470 FRONTAGE INVESTORS LLC, Address:% KESSINGER/HUNTER & CO INC  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/14/2004 10/29/2010
Correction

Fire Department; Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. Combustible debris, waste materials and trash shall not be burned on site.
Correction

CA - 2000 IBC 1003.2.10 - Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visable to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet from the nearest visible exit sign.
Correction

CA - 2000 IBC 1003.2.11 - The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - As the construction type is II-B, all construction elements shall be of non-combustible elements.
Correction

CA - ANSI A117.1-1998 404.2.3 - Clear width. Doorways shall have a clear opening of 32 inches minimum. Clear opening of doorways with swinging doors shall be measured between the face of door and stop, with the door open 90 degrees. Openings more than 24 inches deep shall provide a clear opening of 36 inches minimum. There shall be no projections into the clear opening width lower than 34 inches above the floor or ground. Projections into the minim clear opening width more than 34 inches and up to 80 inches above the floor or ground are permitted but shall not exceed 4 inches.
Correction

CA - ANSI A117.1-1998 404.2.7 - Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Such hardware shall be 34 inches minimum and 48 inches maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $50.00 $50.00 Paid 07/31/2003
24 BLDG Plan Check Fees $6.00 $6.00 Paid 07/31/2003
25 Electrical Permit Fee $30.00 $30.00 Paid 07/31/2003
25 Plumbing Permit Fees $7.00 $7.00 Paid 07/31/2003
89 Sewer Tap Fees $30.00 $30.00 Paid 07/31/2003
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 08/13/2003
Correction
Resolved
08/13/2003
UNDER-SLAB DWV PIPING SERVING SINK @ BREAK RM OK TO COVER WHEN READY
All Rough Inspection - Commercial Partial 08/18/2003
Correction
Resolved
08/18/2003
IN-WALL SYSTEMS @ ROOMS 101-106 APPROVED OK TO COVER WHEN READY
Correction
Corrective Action Required
08/18/2003
ELECTRIAL POWER FEEDS TO FURNACES NOT HARD WIRED CORD & PLUG FED
Correction
Corrective Action Required
08/18/2003
GAS FEEDER DROPS IRC G2417: SUPPORT LATERALLY TO PROTECT FROM DAMAGE AT FURNACES NOT SUPPORTED LATERALLY
Correction
Corrective Action Required
08/18/2003
COMBUSTION AIR & VENT STACKS NOT SUPPORTED VERTICALLY NORTH & SOUTH FURNACES
Correction
Corrective Action Required
08/18/2003
ELECT CONDUIT & BOXES @ OFC 109 & NORTH NOT SECURED TO WALL
Correction
Corrective Action Required
08/18/2003
ELECT RECEPT ABOVE OFC 109 HANGING OPEN
Correction
Corrective Action Required
08/18/2003
ELECT CONDUIT + BOX @ RM 110 NE HUNG FROM LIGHT FIXTURE
Correction
Corrective Action Required
08/18/2003
ELECTRICAL FIXTURE @ RM 110 SE SUPPORTED FROM DUCT; CORD-PLUG FED
Correction
Corrective Action Required
08/18/2003
STORAGE MEZZANINE IBC 1003.3 SEE IBC FOR REQUIREMENTS RE STAIR; FALL PROTECTION
All Rough Inspection - Commercial Passed 09/04/2003
Correction
Resolved
09/04/2003
STORAGE MEZZANINE OK FOR USE BY COMPANY PERSONNEL ONLY
Correction
Resolved
09/04/2003
ELECTRICAL FIXTURE @ RM 110 SE
Correction
Resolved
09/04/2003
ELECT CONDUIT + BOX @ RM 110 NE
Correction
Resolved
09/04/2003
ELECT RECEPT ABOVE OFC 109
Correction
Resolved
09/04/2003
ELECT CONDUIT & BOXES @ OFC 109 & NORTH
Correction
Resolved
09/04/2003
COMBUSTION AIR & VENT STACKS EXISTING CONDITION. RECOMMEND VERTICAL SUPPORT. NOT SUPPORTED VERTICALLY NORTH & SOUTH FURNACES
Correction
Resolved
09/04/2003
GAS FEEDER DROPS RECOMMEND SUPPORT LATERALLY TO PROTECT FROM DAMAGE AT FURNACES NOT SUPPORTED LATERALLY
Correction
Resolved
09/04/2003
ELECTRIAL POWER FEEDS TO FURNACES
Correction
Resolved
09/04/2003
IN-WALL SYSTEMS @ ROOMS 101-106
Occupancy Inspection - Codes Commercial Passed 09/04/2003
Correction
Resolved
09/04/2003
OCCUPANCY STATUS OK TO OCCUPY ISSUE COFO > CLOSE PERMIT
Correction
Resolved
09/04/2003
Receive Fire Department approval PER N ULLERY 9/4/03
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home