Summary
B0301319
Building Permit - Commercial
Certificate of Occupancy
RAINTREE LAKE PROPERTY OWNERS ASSO INC
NEW COMMERCIAL
NEW BUILDING
07/08/2003
09/18/2003
03/16/2004
03/29/2005
Locations
Contacts
HOLT CONSTRUCTION, Address:PO BOX 595  
RAINTREE LAKE PROPERTY OWNERS ASSO INC, Address:825 SW RAINTREE DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/04/2004 10/29/2010
Correction

CA - ANSI A117.1-1998 404.2.7 - Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Such hardware shall be 34 inches minimum and 48 inches maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Correction

CA - I am unable to locate the water service on the site plans.
Correction

CA - The materials used in the plumbing installation are provided.
Correction

CA - Materials to be used in the electrical installation are not indicated on the plans.
Correction

CA - The plumbing plan does not include the trench drain or the vent sizing.
Correction

CA - Information on the sand and oil separator was not provided with the permit application.
Correction

CA - The plans indicate that the restroom fixtures are to run through the sand and oil separator.
Correction

CA - A electrical panel schedule was not provided.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

CA - 2000 IBC 1109.1 - Required accessible elements shall be identified by the International Symbol of Accessiblity at the locations listed in Section 1109.1. 1. Not applicable as the zoning ordinance is more restrictive. 2. Accessible passenger loading zones. 3. Accessible areas of refuge required by Section 1103.2.13.5. 4. Accessible rooms where multi single-user toilet or bathing rooms are clustered at a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the check-out aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting, and locker rooms where not all such rooms are accessible.
Correction

CA - 2000 IBC 1209.2 - Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture.
Correction

CA - 2000 IBC 1209.1 - In other than dwelling units, toilet and bathing room floors shall have a smooth, hard, nonabsorbent surface that extends upward onto the walls at least 6 inches.
Correction

CA - 2000 IBC 1003.3.1.4 - Floor Elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal.
Correction

CA - 2000 IBC 1003.3.1.6 - Thresholds. Thresholds at doorways shall not exceed 0.75 inch in height for sliding doors serving dwelling units or 0.5 inch for other doors. Raised thresholds and floor level changes greater then 0.25 inch at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope).
Correction

CA - 2000 IBC 1404.2 - Water-resistive barrier. A minimum of one layer of No. 15 asphalt felt, complying with ASTM D 226 for Type 1 felt, shall be attached to the sheathing, with flashing as described in Section 1405.3, in such a manner as to provide a continous water-resistive barrier behind the exterior wall veneer.
Correction

CA - 2000 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as devined in Section 2406.2 shall pass the test requirements of CPSC 16 CFR 1201, listed in Chapter 35. Glazing shall comply with the CSPC 16 CFR, Part 1201 criteria for Category I or Category II as indicated in Table 2406.1.
Correction

Fire Department; IFC 1003.3.1.8 Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department; Egress from a room or space shall not pass through adjoining or interven-ing rooms or areas, except where such adjoining rooms or areas are accessory to the area served; are not a high-hazard occupancy; and provide a discernible path of egress travel to an exit. Egress shall not pass through kitchens, store rooms, closets or spaces used for similar purposes. An exit access shall not pass though a room which can be locked to prevent egress. IFC 1004.2.3
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - 2000 IPC 708.3.2 - Building sewers shall be provided with cleanouts located not more than 100 feet apart measured fron the upstream entrance of the cleanout. For building sewers 8 inches and larger, manholes shall be provided and located at each change in direction and at intervals of not more than 400 feet of developed length of the drainage piping.
Correction

CA - 2000 IPC 708.3.5 - Building drain and building sewer junction. There shall be a cleanout near the junction of the building drain and the building sewer. The cleanout shall be either inside or outside the building wall and shall be brought up to the finished ground level or the basement floor level. An approved two-way cleanout is allowed to be used at this location to serve as a required cleanout for both the building drain and building sewer. The cleanout at the junction of the building drain and building sewer shall not be required if the cleanout on a 3-inch (76 mm) or larger diameter soil stack is located within a developed length of 10 feet (3048 mm) of the building drain and building sewer connection.
Correction

CA - 2000 IPC 504.4 - Relief valve. All storage water heaters operating above atmospheric pressure shall be provided with an approved, self-closing (levered) pressure relief valve and temperature relief valves or combination thereof. The relief valve shall conform to ANSI Z21.22. The relief valve shall not be used as a means of controlling thermal expansion.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

A note should be provided indicating a Reduce Pressure Zone (RPZ) principal backflow prevention device will be placed inside the building on the domestic water service line prior to any point of use.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Correction

All proposed hose bibb connections must have an approved (vacuum breaker) backflow preventer.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $593.00 $593.00 Paid 09/18/2003
24 BLDG Plan Check Fees $29.85 $29.85 Paid 09/18/2003
25 Electrical Permit Fee $80.00 $80.00 Paid 09/18/2003
25 Plumbing Permit Fees $28.00 $28.00 Paid 09/18/2003
89 Sewer Tap Fees $90.00 $90.00 Paid 09/18/2003
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Not Ready 10/03/2003
Correction
Corrective Action Required
10/03/2003
TEXT NOT READY FOR INSPECTION.
Footing Inspection - Commercial Passed 10/06/2003
Correction
Resolved
10/06/2003
TEXT APPROVED PER PLANS SUBMITTED.
Underslab Plumbing Inspection - Commercial Passed 10/08/2003
Correction
Resolved
10/08/2003
None
Water Service Inspection Passed 10/20/2003
Correction
Resolved
10/20/2003
None
Water Service Inspection - Commercial Request Complete 10/20/2003 10/20/2003 10/20/2003
Sewer Service Inspection Partial 10/21/2003
Correction
Partial Correction
10/21/2003
BELOW APPROVED TO 25 FT. PAST 3RD CLEANOUT ON N/ S RUN.
Sewer Service Inspection Partial 10/22/2003
Sewer Service Inspection - Commercial Request Complete 10/21/2003 10/22/2003 10/22/2003
Sewer Service Inspection - Commercial Request Complete 12/1/2003 12/1/2003 12/01/2003
Sewer Service Inspection - Commercial Request Complete 12/2/2003 12/2/2003 12/02/2003
Sewer Service Inspection Passed 12/08/2003
Correction
Resolved
12/08/2003
BELOW APPROVED TO 25 FT. PAST 3RD CLEANOUT ON N/ S RUN.
All Rough Inspection - Commercial Failed 01/21/2004
Correction
Corrective Action Required
01/21/2004
Bathroom ventilation (IRC) EXTEND DUCT FROM BATH EXHAUST TO EXTERIOR
Correction
Corrective Action Required
01/21/2004
Glazing at Hazardous Locations (IRC) TWO SASH WINDOW ADJACENT TO WALK DOOR REQUIRES TEMPERED SAFETY GLASS
All Rough Inspection - Commercial Failed 02/10/2004
Correction
Resolved
02/10/2004
Bathroom ventilation (IRC)
Electrical Service Inspection Passed 02/10/2004
Correction
Resolved
02/10/2004
None
All Rough Inspection - Commercial Passed 04/06/2004
Correction
Resolved
04/06/2004
Glazing at Hazardous Locations (IRC)
Occupancy Inspection - Codes Commercial Failed 04/06/2004
Correction
Corrective Action Required
04/06/2004
ADDRESS PROVIDE ADDRESS EXTERIOR
Correction
Corrective Action Required
04/06/2004
SPLASHBLOCKS PROVIDE 36" SPLASHBLOCKS EXTERIOR
Correction
Corrective Action Required
04/06/2004
Panel Circuit Identification (IRC) PANEL NOT PROPERLY MARKED. EACH BREAKER IS TO BE IDENTIFIED INDIVIDUALLY AND SOME BREAKERS ARE MISIDENTIFIED
Correction
Corrective Action Required
04/06/2004
Receive Planning & Development Approval RECEIVE PLANNING AND DEVELOPMENT APPROVAL UNDER SEPARATE COVER. INSTALL VINYL FENCE
Correction
Corrective Action Required
04/06/2004
Receive Public Works Approval RECEIVE PUBLIC WORKS APPROVAL UNDER SEPARATE COVER. DRIVEWAY APPROACH MODIFICATION. SEEDING AND DISBURSEMENT OF STRAW ON DISTURBED GROUND
Correction
Corrective Action Required
04/06/2004
Receive Water Utilities Approval RECEIVE WATER UTILITIES APPROVAL UNDER SEPARATE COVER. PROVIDE BACKFLOW DEVICE TESTING REPORT
Correction
Corrective Action Required
04/06/2004
Receive Fire Department approval RECEIVE FIRE DEPARTMENT APPROVAL UNDER SEPARATE COVER
Occupancy Inspection - Codes Commercial Passed 06/28/2004
Correction
Resolved
06/28/2004
ADDRESS EXTERIOR
Correction
Resolved
06/28/2004
SPLASHBLOCKS EXTERIOR
Correction
Resolved
06/28/2004
Panel Circuit Identification (IRC)
Correction
Resolved
06/28/2004
Receive Planning & Development Approval
Correction
Resolved
06/28/2004
Receive Public Works Approval
Correction
Resolved
06/28/2004
Receive Water Utilities Approval
Correction
Resolved
06/28/2004
Receive Fire Department approval
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home