Summary
B0300786
Building Permit - Commercial
Certificate of Occupancy
CP DEER BROOK PLAZA LLC
CHANGE OF TENANT
CHICAGO TITLE TENANT FINISH
05/06/2003
05/13/2003
11/09/2003
07/07/2003
Locations
Contacts
BRUCE BEST, AGMP (ARCHITECTURE GRAPHICS MANAGEME, Address:226 S DOUGLAS STREET  
WARD DEVELOPMENT COMPANY, Address:620 JEFFERSON  
CP DEER BROOK PLAZA LLC, Address:3400 COLLEGE BLVD STE 195  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 11/02/2003 10/29/2010
Correction

CA - ANSI A117.1-1998 404.2.7 - Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Such hardware shall be 34 inches minimum and 48 inches maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - 2000 IBC 1109.1 - Required accessible elements shall be identified by the International Symbol of Accessiblity at the locations listed in Section 1109.1. 1. Not applicable as the zoning ordinance is more restrictive. 2. Accessible passenger loading zones. 3. Accessible areas of refuge required by Section 1103.2.13.5. 4. Accessible rooms where multi single-user toilet or bathing rooms are clustered at a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the check-out aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting, and locker rooms where not all such rooms are accessible.
Correction

CA - 2000 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as devined in Section 2406.2 shall pass the test requirements of CPSC 16 CFR 1201, listed in Chapter 35. Glazing shall comply with the CSPC 16 CFR, Part 1201 criteria for Category I or Category II as indicated in Table 2406.1.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department: Fire detection, alarm and extinguishing systems shall be maintained in an op-erative condition at all times, and shall be replaced or repaired where defective.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - 2000 IMC 602.2.1 - Except as required by Section 602.2.1.1 through 602.2.1.4, materials exposed within plenumbs shall be noncombustible or shall have a flame spread index of not more than 25 and a smoke-developed index of not more than 50 when tested in accordance with ASTM E 84.
Correction

CA - 2000 IPC 410.1 - Drinking fountains shall conform to ASME A112.19.1, ASME A 112.19.2 or ASME A 112.19.9, and water coolers shall conform to ARI 1010. Where water is served in restaurants or where bottled water coolers or disposable cups next to a sink are provided in other occupancies, drinking fountains shall not be required. (As ammended in the LSCO Section 7-407.)
Correction

CA - 2000 IPC 308.5 - Pipe shall be supported in accordance with Table 308.5.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $77.50 $77.50 Paid 05/13/2003
24 BLDG Plan Check Fees $8.25 $8.25 Paid 05/13/2003
25 Electrical Permit Fee $45.00 $45.00 Paid 05/13/2003
25 Mechanical Permit Fees $15.00 $15.00 Paid 05/13/2003
25 Plumbing Permit Fees $13.00 $13.00 Paid 05/13/2003
89 Sewer Tap Fees $60.00 $60.00 Paid 05/13/2003
BLDG Reinspection Fees $30.00 $30.00 Paid 06/27/2003
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Not Ready 05/14/2003
Correction
Corrective Action Required
05/14/2003
No Plans CALL FOR REINSPECTION
All Rough Inspection - Commercial Failed 05/15/2003
Correction
Corrective Action Required
05/15/2003
No Plans COMPLETE REQD RATED DEMISING WALLS GROUND ROUGH APPROVED IN WALL SYSTEMS ONLY APPROVED PROVIDE ACCESS TO DCD IN WALL
All Rough Inspection - Commercial Failed 06/06/2003
Correction
Corrective Action Required
06/06/2003
No Plans NORTN & SOUTH RATED WALLS - FIREBLOCK AT PENETRATIONS (BEAMS, ROMEX, PIPES) PROVIDE ACCESS TO DCD IN WALL, BACKFLOW TO BE TESTED & RESULTS FORWARDED TO WATER UTILITIES.
Above Ceiling Inspection Failed 06/06/2003
Correction
Corrective Action Required
06/06/2003
Not Ready
Above Ceiling Inspection Failed 06/10/2003
Correction
Corrective Action Required
06/10/2003
NO ACCESS
Rough Framing Inspection - Commercial Passed 06/11/2003
Correction
Resolved
06/11/2003
None
Rough Mechanical Inspection - Commercial Passed 06/11/2003
Correction
Resolved
06/11/2003
None
Above Ceiling Inspection Passed 06/11/2003
Correction
Resolved
06/11/2003
Not Ready
Correction
Resolved
06/11/2003
NO ACCESS
Correction
Resolved
06/11/2003
None OKAY TO HANG TILE
All Rough Inspection - Commercial Failed 06/11/2003
Correction
Corrective Action Required
06/11/2003
No Plans PROVIDE ACCESS TO DCD IN WALL, BACKFLOW TO BE TESTED & RESULTS FORWARDED TO WATER UTILITIES.
Rough Electrical Inspection - Commercial Passed 06/11/2003
Correction
Resolved
06/11/2003
None
All Rough Inspection - Commercial Passed 06/30/2003
Correction
Resolved
06/30/2003
No Plans
Occupancy Inspection - Codes Commercial Failed 06/30/2003
Correction
Corrective Action Required
06/30/2003
Receive Fire Department approval
Correction
Resolved
06/30/2003
Receive Water Utilities Approval
Correction
Corrective Action Required
06/30/2003
Signage INSTALL "DOOR TO REMAIN UNLOCKED DURING BUSSINESS HOURS"
Correction
Corrective Action Required
06/30/2003
Electrical Listing & Labeling (IRC) SERVICE PANEL BREAKERS LABELED ON SCRAPE OF CARDBOARD & FASTEN WITH PLASTIC TAPE. PROVIDE MORE PERMAMENT LABEL.
Correction
Corrective Action Required
06/30/2003
Signage INSTALL AT RESTROOM DOORS
Correction
Corrective Action Required
06/30/2003
Do Not Occupy
Occupancy Inspection - Codes Commercial Passed 07/03/2003
Correction
Resolved
07/03/2003
Receive Fire Department approval
Correction
Resolved
07/03/2003
Signage INSTALL "DOOR TO REMAIN UNLOCKED DURING BUSSINESS HOURS"
Correction
Resolved
07/03/2003
Electrical Listing & Labeling (IRC) SERVICE PANEL BREAKERS LABELED ON SCRAPE OF CARDBOARD & FASTEN WITH PLASTIC TAPE. PROVIDE MORE PERMAMENT LABEL.
Correction
Resolved
07/03/2003
Signage INSTALL AT RESTROOM DOORS
Correction
Resolved
07/03/2003
Do Not Occupy
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home