Permit Application Status

B0300643


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0300643
Building Permit - Commercial
Certificate of Occupancy
TRD REAL ESTATE LLC
NEW COMMERCIAL
NEW COMMERCIAL BUILDING
04/18/2003
05/22/2003
11/18/2003
03/30/2004
Locations
Contacts
ROSE CONSTRUCTION COMPANY INC, Address:1805 E 123RD ST  
TRD REAL ESTATE LLC, Address:607 NW BLUE PARKWAY  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 10/15/2003 10/29/2010
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Codes Admin. - Submit a stair detail including rise/run handrail and guardrail details per UBC Section 1003.3.3.3.
Correction

Codes Admin. - All door hardware must be accessible type hardware.
Correction

Codes Admin. - Special inspections must be performed on any structural masonary walls.
Correction

Codes Admin. - The guard rail located on the retaining wall must extend to the point when the change in elevation is less than 30" on both sides of the wall.
Correction

Codes Admin. - All DWV piping must be properly supported per the IPC Seciton 308.
Correction

Codes Admin. - The unit heater located in the restroom of repair garage must be elevated a minimum of 18" above the floor per IMC Section 304.3.
Correction

Codes Admin. - All gas piping must be supported per IFGC Table 305.4.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

CA - 2000 IBC 1109.1 - Required accessible elements shall be identified by the International Symbol of Accessiblity at the locations listed in Section 1109.1. 1. Not applicable as the zoning ordinance is more restrictive. 2. Accessible passenger loading zones. 3. Accessible areas of refuge required by Section 1103.2.13.5. 4. Accessible rooms where multi single-user toilet or bathing rooms are clustered at a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the check-out aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting, and locker rooms where not all such rooms are accessible.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - 2000 IMC 606.2.2 - Common supply and return air systems. Where multiple air-handling systems share common supply or return air ducts or plenums with a combined design capacity greater than 2,000 cfm, the return air system shall be provided with smoke detectors in accordance with Section 606.2.1.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; An approved lock shall be installed on gates or similar barriers when required by the code official.
Correction

CA - 2000 IPC 312.1 - Required tests. The permit holder shall make the applicable test prescribed in Sections 312.2 through 312.9 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain if the pressure has reached all parts of the system. Note: Testing of the plumbing system is not required to be witnessed by the Codes Administration Staff with the exception of gas piping.
Correction

CA - 1999 NEC 210-63 - Heating, Air-Conditioning, and Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing fo heating, air-conditioning, and refrigeration equipment on rooftops and in attics and crawl spaces. The receptacle shall be located on the same level and within 25 ft (7.62m) of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $2,072.00 $2,072.00 Paid 05/22/2003
24 BLDG Plan Check Fees $54.50 $54.50 Paid 05/22/2003
25 Electrical Permit Fee $302.85 $302.85 Paid 05/22/2003
25 Mechanical Permit Fees $64.00 $64.00 Paid 05/22/2003
25 Plumbing Permit Fees $32.00 $32.00 Paid 05/22/2003
84 Water Meters $200.00 $200.00 Paid 05/22/2003
85 Water Taps $5,468.00 $5,468.00 Paid 05/22/2003
89 Sewer Tap Fees $150.00 $150.00 Paid 05/22/2003
Right of Way Permit $35.00 $35.00 Paid 05/22/2003
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 06/06/2003
Correction
Partial Correction
06/06/2003
FOOTING PREPARATION -PARTIAL ALL EXCEPT SE STAIRWELL OK TO POUR WHEN READY
Occupancy Inspection - Codes Commercial Failed 06/19/2003
Correction
Corrective Action Required
06/19/2003
EASEMENT FOR NEW FIRE HYDRANT SUBMIT TO JUDY NIEMEYER @ PUBLIC WORKS ENGINEERING
Foundation Inspection - Commercial Partial 06/20/2003
Correction
Partial Correction
06/20/2003
FOUNDATION/BASEMENT WALLS TO GRADE - PARTIAL W; N; E WALLS OK TO POUR WHEN READY
Footing Inspection - Commercial Passed 06/25/2003
Correction
Resolved
06/25/2003
FOOTING PREPARATION - FINAL PARTIAL SE STAIRWELL SLAB
Correction
Resolved
06/25/2003
FOOTING PREPARATION -PARTIAL ALL EXCEPT SE STAIRWELL
Foundation Inspection - Commercial Passed 06/27/2003
Correction
Resolved
06/27/2003
FOUNDATION/BASEMENT WALLS TO GRADE - PARTIAL W; N; E WALLS OK TO POUR WHEN READY
Correction
Resolved
06/27/2003
FOUNDATION/BASEMENT WALLS TO GRADE - PARTIAL SOUTH WALL + WALLS @ STAIRWELLS
Footing Inspection - Commercial Partial 07/09/2003
Correction
Partial Correction
07/09/2003
FOOTING - PARTIAL PER REVISED WALL DETAIL XS1. OK TO POUR WHEN READY. ON (A.5) FROM (2) TO (1) ON (1) FROM (A.5) TO (F)
Foundation Inspection - Commercial Partial 07/11/2003
Correction
Partial Correction
07/11/2003
FOUNDATION/BASEMENT WALL TO GRADE PER REVISED WALL DETAIL XS1. OK TO POUR WHEN READY. ON (A.5) FROM (2) TO (1) ON (1) FROM (A.5) TO (F)
Correction
Partial Correction
07/11/2003
EASTMOST FOUNDATION WALL
Footing Inspection - Commercial Partial 08/06/2003
Correction
Partial Correction
08/06/2003
OUTER FOOTING NE CORNER
Correction
Resolved
08/06/2003
FOOTING - PARTIAL PER REVISED WALL DETAIL XS1. ON (A.5) FROM (2) TO (1) ON (1) FROM (A.5) TO (F)
Underslab Plumbing Inspection - Commercial Partial 08/13/2003
Correction
Partial Correction
08/13/2003
UNDER-FLOOR DWV PIPING OK TO COVER WHEN READY AT RR's 116 & 118 4" SAN LINE W TO BASMENT
Correction
Partial Correction
08/13/2003
TRENCH DRAINS @ SERVICE BAYS 119 OK TO COVER WHEN READY 4" S&O LINE WTO SEPARATOR YET TO BE CONNECTED
Underslab Electrical Inspection - Commercial Partial 08/13/2003
Correction
Partial Correction
08/13/2003
UNDER-SLAB SECONDARY SERVICE FEEDER CONDUIT FIVE 1-3/4" + TWO 3" PVC SCH 40 CONDUITS. OK TO COVER WHEN READY C.T. CABINET LOCATION TO MDP LOCATION
Sewer Service Inspection Passed 08/14/2003
Correction
Resolved
08/14/2003
None AS PER PLAN. M. WEISENBORN APPROVED TAP AT MAIN
All Rough Inspection - Commercial Failed 10/07/2003
Correction
Corrective Action Required
10/07/2003
PROTECTION OF WATER PIPING AT PENETRATION OF METAL WALL STUDS & TRACKS
Underslab Plumbing Inspection - Commercial Passed 10/08/2003
Correction
Resolved
10/08/2003
UNDER-FLOOR DWV PIPING AT RR's 116 & 118 4" SAN LINE W TO BASMENT
Correction
Resolved
10/08/2003
TRENCH DRAINS @ SERVICE BAYS 119 4" S&O LINE WTO SEPARATOR YET TO BE CONNECTED
Underslab Electrical Inspection - Commercial Passed 10/08/2003
Correction
Resolved
10/08/2003
UNDER-SLAB SECONDARY SERVICE FEEDER CONDUIT FIVE 1-3/4" + TWO 3" PVC SCH 40 CONDUITS. C.T. CABINET LOCATION TO MDP LOCATION
Footing Inspection - Commercial Passed 10/08/2003
Correction
Resolved
10/08/2003
OUTER FOOTING NE CORNER
Correction
Resolved
10/08/2003
FOOTING - PARTIAL PER REVISED WALL DETAIL XS1. ON (A.5) FROM (2) TO (1) ON (1) FROM (A.5) TO (F)
Foundation Inspection - Commercial Passed 10/08/2003
Correction
Resolved
10/08/2003
EASTMOST FOUNDATION WALL
Correction
Resolved
10/08/2003
FOUNDATION/BASEMENT WALL TO GRADE PER REVISED WALL DETAIL XS1. ON (A.5) FROM (2) TO (1) ON (1) FROM (A.5) TO (F)
All Rough Inspection - Commercial Failed 10/08/2003
Correction
Partial Correction
10/08/2003
PROTECTION OF WATER PIPING PIPING @ RR 118 NOT YET PROTECTED AT PENETRATION OF METAL WALL STUDS & TRACKS
All Rough Inspection - Commercial Passed 10/10/2003
Correction
Resolved
10/10/2003
PROTECTION OF WATER PIPING
Retaining Wall Inspection Partial 10/14/2003
Correction
Partial Correction
10/14/2003
E-W @ SE BLDG CORNER PER DRWGS S1 & S2 OK TO POUR WHEN READY SUBJECT TO TERRACON REC
Gas Piping Inspection - Commercial Failed 10/15/2003
Correction
Corrective Action Required
10/15/2003
PIPE HANGER @ SALES 108 ROD BEARING AGAINST COPPER WATER PIPE
Correction
Corrective Action Required
10/15/2003
DISTORTION OF ROOF PURLIN FLANGES AT PIPE HANGER LOCATIONS
Gas Service Inspection - Commercial Passed 10/15/2003
Correction
Resolved
10/15/2003
PRESSURE TEST RELEASE GAS SERVICE HELD STEADY AT >= 10 PSI FOR 10 MIN
Rough Framing Inspection - Commercial Failed 10/15/2003
Correction
Corrective Action Required
10/15/2003
ROOF PURLIN FLANGES REPAIR OR PROVIDE ENGINEER LETTER ACCEPTING DISTORTION. DISTORTED BY HANGERCLAMPS VARIOUS LOCATIONS
Water Service Inspection Passed 10/16/2003
Correction
Resolved
10/16/2003
DOMESTIC WATER SERVICE INSTALLATION TAP; METER COMPLETE SVC LINE TO BLDG ENTRY
Foundation Inspection - Commercial Passed 10/16/2003
Correction
Resolved
10/16/2003
FOUNDATION/BASEMENT WALLS TO GRADE - PARTIAL W; N; E WALLS
Correction
Resolved
10/16/2003
EAST STAIR @ S ELEVATION OUTER WALL E 9' LAST OF STRUCTURAL CONC
Water Service Inspection - Commercial Request Complete 10/15/2003 10/16/2003 10/16/2003
Retaining Wall Inspection Passed 11/03/2003
Correction
Resolved
11/03/2003
E-W @ SE BLDG CORNER
Above Ceiling Inspection Failed 11/03/2003
Correction
Corrective Action Required
11/03/2003
ELECTRICAL WORK IN PROGRESS TEMPORARY ELECTRICAL LIGHTING STRINGS NOT REMOVED OPEN BOXES UNTERMINATED CONDUCTORS
Gas Piping Inspection - Commercial Failed 11/03/2003
Correction
Resolved
11/03/2003
PIPE HANGER @ SALES 108
Rough Framing Inspection - Commercial Failed 11/03/2003
Above Ceiling Inspection Failed 11/04/2003
Correction
Corrective Action Required
11/04/2003
SUPPORT OF HVAC FLEXIBLE DUCT AND NOT MORE THAN 10' ON CENTER SUPPORT AT INTERVALS PER MFGRS INSTRUCTIONS
Correction
Resolved
11/04/2003
ELECTRICAL WORK IN PROGRESS
Electrical Service Inspection Passed 11/04/2003
Correction
Resolved
11/04/2003
ELECTRICAL SERVICE INSTALLATION 600 AMP RELEASE SERVICE
Above Ceiling Inspection Passed 11/12/2003
Correction
Resolved
11/12/2003
SUPPORT OF HVAC FLEXIBLE DUCT
Occupancy Inspection - Codes Commercial Failed 11/12/2003
Correction
Corrective Action Required
11/12/2003
EASEMENT FOR NEW FIRE HYDRANT SUBMIT TO JUDY NIEMEYER @ PUBLIC WORKS ENGINEERING
Correction
Corrective Action Required
11/12/2003
PERMIT FOR DEMOLITION OF EXISTING BUILDING TO BE CLARIFIED
Correction
Corrective Action Required
11/12/2003
Receive Water Utilities Approval
Correction
Corrective Action Required
11/12/2003
Receive Public Works Approval ISSUES DISCUSSED ON-SITE 11/12/03 W/ JON HALEY
Correction
Corrective Action Required
11/12/2003
Receive Planning & Development Approval
Correction
Corrective Action Required
11/12/2003
Receive Fire Department approval
Underground Electrical Inspection - Commercial Passed 12/08/2003
Correction
Resolved
12/08/2003
U.G. CONDUIT FOR LOT LIGHTING NOTE: POLE BASES NOT DETAILED NOR SPECIFIED BY A/E; G.C. STATES POLE MANUFACTURER PROVIDED NO SPECS FOR BASES. BASES ARE SIZED & REINFORCED PER G.C. TRENCHED & PLACED >= 24" DEEP
Underground Electrical Inspection - Commercial Request Complete 12/8/2003 12/9/2003 12/09/2003
Occupancy Inspection - Codes Commercial Failed 01/27/2004
Correction
Resolved
01/27/2004
EASEMENT FOR NEW FIRE HYDRANT OBTAINED BY PW PER J HALEY 11/19/03
Correction
Resolved
01/27/2004
Receive Water Utilities Approval PER J WALTERS 11/13/03
Correction
Resolved
01/27/2004
PERMIT FOR DEMOLITION OF EXISTING BUILDING OBTAINED AND CLOSED
Correction
Corrective Action Required
01/27/2004
Receive Planning & Development Approval NOT READY FOR FINAL INSPECTION. CALL WHEN READY. IF TRASH ENCLOSURE SHOWN ON DRAWINGS IS NOT TO BE CONSTRUCTED SUBMIT WRITTEN STATEMENT INDICATING THAT IS THE CASE. PARKING LOT WEST OF DEMOLISHED BLDG
Correction
Corrective Action Required
01/27/2004
Receive Public Works Approval AFFIDAVIT OF PAYMENT STILL REQUIRED TO BE SUBMITTED PER J HALEY 12/12/03 MAINTENANCE BOND +
Occupancy Inspection - Codes Commercial Failed 02/12/2004
Correction
Resolved
02/12/2004
Receive Fire Department approval PER N ULLERY 2/12/04
Occupancy Inspection - Codes Commercial Passed 03/30/2004
Correction
Resolved
03/30/2004
Receive Planning & Development Approval PER JON HALEY 03/30/04
Correction
Resolved
03/30/2004
Receive Public Works Approval PER J HALEY 03/30/04
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home