Summary
B0300626
Building Permit - Residential
Certificate of Occupancy
HAUB WAYNE B & SHIRLEY A
NEW SINGLE FAMILY
HOUSE AND DECK
04/15/2003
04/29/2003
10/26/2003
12/21/2004
Locations
Contacts
RIFFEE HOMES INC., Address:450 WINNEBAGO DRIVE  
HAUB WAYNE B & SHIRLEY A, Address:2333 LAKEBREEZE LANE  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 10/12/2003 10/29/2010
Correction

Codes Administration- Bedrooms located in basements shall have at least one operable window or door approved for emergency escape which opens to the exterior. All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet. The net clear openable height shall be 24 inches. The minimum net clear openable width shall be 20 inches. The finished sill height shall not exceed 44 inches above the finished floor. (UBC Section 1204).
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - The holder of this permit agrees and understands that the work authorized by this permit shall be performed in accordance with the 2000 International Residential Code as amended by Chapter 7 of the Lee's Summit Code of Ordinances.
Correction

CA - The holder of this permit agrees and understands that only persons authorized per LSCO 7-130 are permitted to perform electrical, plumbing or mechanical work authorized by this permit.
Correction

In a combined effort with both the R-4, and the R-7 School Districts the City of Lee's Summit is working together to educate the development community on a new program, the "Lee's Summit Voluntary Residential Development Surcharge". This is a program, which will help raise capital to build new schools for our community. Brochures are available at the front counter of both the Planning and Development and the Codes Administration departments. You can also find more information on the City of Lee's Summit web site at lees-summit.mo.us. (For more information please contact the Board of Education at 986-2400).
Correction

CA - 2000 IRC 401.3 - Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 inches (152 mm) within the first 10 feet (3048 mm). 2000 IRC, Section 401.3
Correction

CA - 2000 IRC 403.1.6 - Foundation sills and exterior wall sole plates shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet on center. Anchor bolts shall be located within 12 inches from the end of each plate section. Anchor bolts shall be 1/2 inch in diameter and shall extend a minimum of 7 inches into the concrete. A nut and washer shall be tightened on each bolt to the plate. 2000 IRC, Section 403.1.6
Correction

CA - 2000 IRC 403.7.3 - The top of any exterior foundation shall extend above the elevation of the street curb or approved drainage device a minimum of 12" (twelve inches) plus 2%. Alternative elevations are permitted subject to approval of the building official, provided it can be demonstrated that required drainage to the point of discharge and away from the structure is provided at all locations on site. 2000 IRC, Section 403.7.3
Correction

CA - 2000 IRC 703.9 - Foundation walls shall extend above the finished grade a minimum of 4 inches where masonry veneer is used and a minimum of 6 inches elsewhere. (2000 IRC, Section 404.1.6) Exterior Insulation Finish Systems, EFIS, shall terminate not less than 6 inches above finished grade. (2000 IRC, Section 703.9)
Correction

CA - 2000 IRC 314.3 - The minimum headroom in all parts of stairways shall not be less than 6 feet 8 inches measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-122 - Any excavation for foundations and/or footings of buildings and structures shall be backfilled within twenty-eight (28) days from the date of permit issuance unless otherwise approved by the building official.
Correction

CA - LSCO 7-128 (a)1 - Retaining walls which are over 4 feet in height measured from the bottom of the footing to the top of the wall of the wall shall be designed and sealed by a professional engineer or architect registered in the State of Missouri. In addition, the building official may waive the requirements for a permit or engineered drawings for walls over 4 feet in height if it is deemed unnecessary to require such submittals due to the location and type of wall to be installed.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-168 A - Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place before inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94; the concrete need not be on the job.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - LSCO 7-930 - All dwellings shall have a controlled method of water disposal from the roofs that will collect and discharge all roof drainage to the ground at least 3 feet from the foundation walls or to an approved drainage system.
Correction

CA - 2000 IRC 405.1 - Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or useable space. Drainage tiles, gravel drains or perforated pipe drainage systems shall be installed at or below the area to be protected and discharge by gravity or mechanical means. Perforated pipe shall be placed upon at least 2 inches of washed gravel or crushed rock and covered with not less than 6 inches of the same material. (2000 IRC, Section 405.1)
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $1,013.00 $1,013.00 Paid 04/29/2003
25 Electrical Permit Fee $269.50 $269.50 Paid 04/29/2003
25 Mechanical Permit Fees $110.50 $110.50 Paid 04/29/2003
25 Plumbing Permit Fees $63.00 $63.00 Paid 04/29/2003
89 Sewer Tap Fees $630.00 $630.00 Paid 04/29/2003
Right of Way Permit $35.00 $35.00 Paid 04/29/2003
25 Electrical Permit Fee $30.00 $30.00 Paid 03/17/2004
BLDG Reinspection Fees $30.00 $30.00 Paid 12/09/2004
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 05/20/2003
Correction
Resolved
05/20/2003
NONE None FOOTING APPROVE. OK TO POUR.
Underslab Plumbing Inspection - Residential Passed 07/16/2003
Correction
Resolved
07/16/2003
NONE None
Water Service Inspection - R Passed 09/03/2003
Correction
Resolved
09/03/2003
NONE None
Sewer Service Inspection - R Partial 09/03/2003
Correction
Partial Correction
09/03/2003
MISC Sewer Connection APPROVED TO A POINT WITHIN 10` OF WATER METER. UNABLE TO LOCATE RISER.
Sewer Service Inspection - R Passed 09/05/2003
Correction
Resolved
09/05/2003
MISC Sewer Connection
Piers/Caissons Inspection - Residential Passed 10/01/2003
Correction
Resolved
10/01/2003
NONE None 4 - 24" X 36" PIERS AS PER PIER
All Rough Inspection - Residential Passed 10/03/2003
Correction
Resolved
10/03/2003
NONE None FLASHING Entryway
Gas Piping Inspection - Residential Failed 01/16/2004
Correction
Corrective Action Required
01/16/2004
G2417.2 Gas Piping Design & Installation (IRC) DBL TOP PLATE NOTCHED IN EXCESS OF 80 PERCENT AT GAS LINE ENTRY SITE Basement
Correction
Corrective Action Required
01/16/2004
G2417.2 Gas Piping Design & Installation (IRC) SEPARATE OPPOSING METALS FROM CONTACT
Gas Service Inspection - Residential Failed 01/16/2004
Correction
Corrective Action Required
01/16/2004
MISC Insufficient Pressure
Gas Service Inspection - Residential Partial 01/21/2004
Correction
Partial Correction
01/21/2004
MISC Insufficient Pressure HELD 12 PSI. RELEASE METER. NOTE: WHEN GAS LINE IS COMPLETED GAS METER WILL HAVE TO BE DISCONNECTED & PRESSURIZED FOR TEST OF ENTIRE LINE.
Gas Piping Inspection - Residential Partial 01/21/2004
Correction
Resolved
01/21/2004
G2417.2 Gas Piping Design & Installation (IRC)
Correction
Resolved
01/21/2004
G2417.2 Gas Piping Design & Installation (IRC)
Correction
Partial Correction
01/21/2004
MISC See Text GAS LINES NOT RAN TO FIREPLACES OR DECK/PATIO. ONLY MAIN LINE & FURNACE LINES - APPROVED
Gas Service Inspection - Residential Not Ready 01/23/2004
Correction
Corrective Action Required
01/23/2004
MISC IDENTIFICATION OF ADDRESS IRC R325.1: DISPLAY ADDRESS THROUGHOUT PROJECT. **NO INSPECTIONS PERFORMED ON UNIDENTIFIED PROPERTIES.** NO HOUSE/LOT FOUND DISPLAYING THIS ADDRESS
Gas Service Inspection - Residential Failed 01/26/2004
Correction
Corrective Action Required
01/26/2004
MISC Insufficient Pressure NOTE: WHEN DRIP LEGS ARE INSTALLED REPRESSURIZE FOR TEST OF ENTIRE LINE.
Correction
Resolved
01/26/2004
MISC IDENTIFICATION OF ADDRESS
Gas Piping Inspection - Residential Failed 01/26/2004
Correction
Resolved
01/26/2004
MISC See Text
Correction
Corrective Action Required
01/26/2004
G2418.2 Gas Piping--Drips (IRC) INSTALL ACCESSIBLE DRIP LEGS AT FIREPLACES Basement
Gas Service Inspection - Residential Partial 01/29/2004
Correction
Partial Correction
01/29/2004
MISC Insufficient Pressure NOTE: WHEN LINES TO DECK & 2nd FLOOR ARE INSTALLED REPRESSURIZE FOR TEST OF ENTIRE LINE.
Gas Piping Inspection - Residential Partial 01/29/2004
Correction
Partial Correction
01/29/2004
G2418.2 Gas Piping--Drips (IRC) WILL CHEK FOR ACCESSIBLITY ON FINAL Basement
Correction
Corrective Action Required
01/29/2004
G2417.2 Gas Piping Design & Installation (IRC) LINE TO 2nd FLOOR & DECK NOT INSTALLED.
Piers/Caissons Inspection - Residential Passed 02/11/2004
Correction
Resolved
02/11/2004
NONE None
Gas Piping Inspection - Residential Partial 02/27/2004
Correction
Partial Correction
02/27/2004
G2418.2 Gas Piping--Drips (IRC) WILL CHEK FOR ACCESSIBLITY ON FINAL Basement
Correction
Resolved
02/27/2004
G2417.2 Gas Piping Design & Installation (IRC)
Gas Service Inspection - Residential Passed 02/27/2004
Correction
Resolved
02/27/2004
MISC Insufficient Pressure
All Rough Inspection - Residential Failed 03/02/2004
Correction
Corrective Action Required
03/02/2004
MISC Fireplace NOT FINISHED NOTE: THERE HAS BEEN NO REQUESTS FOR INSPECTION ON ANY OF THE FIREPLACES.
Correction
Corrective Action Required
03/02/2004
MISC Not Finished PLANS CALL FOR NORTH WALL TO BE GLASS. NOT STARTED DOORS NOT INSTALLED ENTRYWAY NOT FINISHED STAIRWAY BEING TAKEN OUT & BEING REBUILT
Correction
Corrective Action Required
03/02/2004
MISC Insulation PARTIALLY INSULATED - REMOVE INSULATION & PLASTIC SHEETING - NO INSPECTION WAS DONE. AREAS NOT STARTED OR FINISHED NOTED. REQUEST INSPECTION.
Correction
Resolved
03/02/2004
NONE None
Erosion Control Inspection Residential Failed 03/02/2004
Correction
Corrective Action Required
03/02/2004
LSCO5029XX2 Tracking Mud, Debris STREET CLEAN UP IS REQUIRED. STREET CLEAN UP SHALL BE PERFORMED IMMEDIATELY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL STREET CLEAN UP HAS BEEN COMPLETED.
Correction
Corrective Action Required
03/02/2004
LSCO 5029 XX Erosion Control EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 03/04/2004
Correction
Corrective Action Required
03/04/2004
MISC Cover At Panels 2 - 200 AMP & 2 - 100 AMP PANELS HOLD METER UNTIL PANEL COVER INSTALLED
All Rough Inspection - Residential Failed 03/04/2004
Correction
Corrective Action Required
03/04/2004
E3304.8 Energized Parts Guarded Against Accidental Contact (IRC) INSTALL COVERS AT SERVICE PANELS
Correction
Corrective Action Required
03/04/2004
MISC Permit UPGRADE - SHOW 2 - 200 AMP & 2 - 100 AMP PANELS
Correction
Corrective Action Required
03/04/2004
E3509.7 Metal Gas Piping Bonding (IRC) Basement
Correction
Corrective Action Required
03/04/2004
MISC Penetration of Air Plenum 3" LINE RUNNING LENGTH WISE IN PLENUM Basement
Correction
Corrective Action Required
03/04/2004
R502.9 Fastening (IRC) AS PER NAILING SCHEDULE
Correction
Corrective Action Required
03/04/2004
R807.1 Attic Access (IRC)
Correction
Corrective Action Required
03/04/2004
LSCO 7-903 Bathroom ventilation (IRC) INSTALL DUCT
Correction
Corrective Action Required
03/04/2004
R802.3 Roof Framing (Details) (IRC) SCAB RAFTERS THAT DO NOT BEAR ON RIDGE Loft
Correction
Corrective Action Required
03/04/2004
LSCO 7-924 Floor Cantilevers (IRC) TO LOFT - PROVIDE ENGINEERS REPORT & BASEMENT
Correction
Corrective Action Required
03/04/2004
R602.6 Stud Drilling and Notching (IRC) INSTALL STUD SHOES Master Bathroom
Correction
Corrective Action Required
03/04/2004
MISC Mechanical Hanger INSTALL AT EAST END OF WOOD BEAM Den
Correction
Corrective Action Required
03/04/2004
R602.8 Fireblocking (IRC) VOID AREA Fireplace
Correction
Corrective Action Required
03/04/2004
MISC Duct FLEX DUCT ON TOP OF CAN LIGHT - FLOW RESTRICTED Kitchen/Base.Batg
Correction
Corrective Action Required
03/04/2004
MISC Joist Hangers INCORRECT JOIST HANGERS INSTALLED
Correction
Corrective Action Required
03/04/2004
R602.8 Fireblocking (IRC) ALL BETWEEN LEVEL PENETRATIONS & PENETRATIONS OF RETURN AIR PLENUMS
Correction
Corrective Action Required
03/04/2004
R802.3 Roof Framing (Details) (IRC) AT ALL HIP RAFTER/RIDGE JUNCTION - INSTALL SUPPORT UNDER JUNCTION OKAY TO INSULATE, DO NOT ROCK
Correction
Resolved
03/04/2004
MISC Not Finished
Correction
Resolved
03/04/2004
MISC Insulation
Erosion Control Inspection Residential Failed 03/04/2004
Miscellaneous Inspection Failed 03/18/2004
Correction
Corrective Action Required
03/18/2004
MISC Fireplace SEE EROSION CONTROL
Erosion Control Inspection Residential Failed 03/18/2004
Correction
Corrective Action Required
03/18/2004
LSCO5029XX2 Tracking Mud, Debris 2nd NOTICE STREET CLEAN UP IS REQUIRED. STREET CLEAN UP SHALL BE PERFORMED IMMEDIATELY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL STREET CLEAN UP HAS BEEN COMPLETED. MOVE CONSTRUCTION OFF STREET & CLEAN MUD
Erosion Control Inspection Residential Failed 03/23/2004
Correction
Corrective Action Required
03/23/2004
LSCO5029XX2 Tracking Mud, Debris 3rd NOTICE STREET CLEAN UP IS REQUIRED. STREET CLEAN UP SHALL BE PERFORMED IMMEDIATELY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL STREET CLEAN UP HAS BEEN COMPLETED. CLEAN MUD & DEBRIS OFF STREET
Correction
Resolved
03/23/2004
LSCO 5029 XX Erosion Control
All Rough Inspection - Residential Not Ready 03/23/2004
Correction
Corrective Action Required
03/23/2004
LSCO 7-160K Reinspection Fee SEE EROSION CONTROL $30.00 REINSPECTION FEE
All Rough Inspection - Residential Failed 03/24/2004
Correction
Corrective Action Required
03/24/2004
MISC Fireplace NO PREVIOUS INSPECTIONS 03/24/04 - INSPECTED INTERIOR OF CHIMNEYS FOR 2 FIREPLACES IN MAIN AREA OF HOUSE DUE TO CONSTRUCTION UNABLE TO OTHER FIREPLACES
Correction
Resolved
03/24/2004
R802.3 Roof Framing (Details) (IRC)
Correction
Resolved
03/24/2004
R602.8 Fireblocking (IRC)
Correction
Resolved
03/24/2004
MISC Joist Hangers
Correction
Resolved
03/24/2004
MISC Duct
Correction
Resolved
03/24/2004
R602.8 Fireblocking (IRC)
Correction
Resolved
03/24/2004
MISC Mechanical Hanger
Correction
Resolved
03/24/2004
R602.6 Stud Drilling and Notching (IRC)
Correction
Resolved
03/24/2004
R802.3 Roof Framing (Details) (IRC)
Correction
Resolved
03/24/2004
LSCO 7-903 Bathroom ventilation (IRC)
Correction
Resolved
03/24/2004
R807.1 Attic Access (IRC)
Correction
Resolved
03/24/2004
R502.9 Fastening (IRC)
Correction
Resolved
03/24/2004
MISC Penetration of Air Plenum
Correction
Resolved
03/24/2004
E3509.7 Metal Gas Piping Bonding (IRC)
Correction
Resolved
03/24/2004
E3304.8 Energized Parts Guarded Against Accidental Contact (IRC)
Correction
Corrective Action Required
03/24/2004
MISC Mech. Hangers FRONT & REAR WALLS AT ROOF - MISSING NAILS OKAY TO INSULATE, DO NOT ROCK
Erosion Control Inspection Residential Passed 03/24/2004
Correction
Resolved
03/24/2004
LSCO5029XX2 Tracking Mud, Debris
Electrical Service Inspection Passed 03/24/2004
Correction
Resolved
03/24/2004
MISC Cover At Panels 2 - 200 AMP & 2 - 100 AMP PANELS. RELEASE METER
All Rough Inspection - Residential Not Ready 03/25/2004
Correction
Corrective Action Required
03/25/2004
MISC See Text NOT READY FOR INSPECTION. NOTE: ENGINEERS REPORTS ON BEAM & TIMBER CONSTRUCTION & FRONT & REAR GLASS WALLS NOT RECEIVED. NO SHEETROCK WILL BE AUTHORIZED UNTIL REPORTS ARE RECEIVED.
All Rough Inspection - Residential Failed 03/26/2004
Correction
Resolved
03/26/2004
LSCO 7-924 Floor Cantilevers (IRC)
Correction
Resolved
03/26/2004
MISC Mech. Hangers
Correction
Corrective Action Required
03/26/2004
MISC See Text ENGINEERS REPORTS ON BEAM & TIMBER CONSTRUCTION & FRONT & REAR GLASS WALLS NOT RECEIVED. NO SHEETROCK WILL BE AUTHORIZED UNTIL REPORTS ARE RECEIVED. OKAY TO INSULATE, DO NOT ROCK
All Rough Inspection - Residential Failed 03/29/2004
Correction
Corrective Action Required
03/29/2004
MISC See Text ENGINEERS REPORTS ON BEAM & TIMBER CONSTRUCTION NOT RECEIVED. NO SHEETROCK WILL BE AUTHORIZED UNTIL REPORTS ARE RECEIVED. OKAY TO INSULATE, DO NOT ROCK
Miscellaneous Inspection Passed 04/05/2004
Correction
Resolved
04/05/2004
MISC Fireplace
Gas Piping Inspection - Residential Partial 04/05/2004
Correction
Partial Correction
04/05/2004
G2418.2 Gas Piping--Drips (IRC) WILL CHECK FOR ACCESSIBLITY ON FINAL Basement
All Rough Inspection - Residential Failed 04/05/2004
Correction
Corrective Action Required
04/05/2004
MISC Fireplace NO PREVIOUS INSPECTIONS 03/24/04 - INSPECTED INTERIOR OF CHIMNEYS FOR 2 FIREPLACES IN MAIN AREA OF HOUSE DUE TO CONSTRUCTION UNABLE TO INSPECT THE OTHER FIREPLACES
Correction
Corrective Action Required
04/05/2004
MISC See Text ENGINEERED PLANS: LOWER LEVEL - STEEL I BEAMS & DIMENSIONAL LUMBER BEAMS NOT AS PER PLANS STAIRS FROM LOWER LEVEL TO LOFT NOT INSTALLED AS PER PLANS SOUTH ENGINEERED GLASS WALL - METAL FRAMING NOT FINISHED. OKAY TO INSULATE, DO NOT ROCK
Rough Mechanical Inspection - Residential Passed 04/05/2004
Correction
Resolved
04/05/2004
NONE None
Rough Plumbing Inspection - Residential Passed 04/05/2004
Correction
Resolved
04/05/2004
NONE None
Rough Electrical Inspection - Residential Passed 04/05/2004
Correction
Resolved
04/05/2004
NONE None
All Rough Inspection - Residential Failed 04/19/2004
All Rough Inspection - Residential Failed 05/04/2004
Correction
Corrective Action Required
05/04/2004
MISC See Text 4 MAY 2004 - JIM, I TRIED TO CALL YOU FOUR (4) TIMES TODAY. THERE WAS NO ANSWER. WE NEED TO GET THE FRAMING PROBLEM IN THE BASEMENT CORRECTED PRIOR ANY FURTHER FINISH WORK BEING COMPLETED. PLEASE CALL & WE WILL SET AN APPOINTMENT TO MEET. DAVID
All Rough Inspection - Residential Failed 05/06/2004
Correction
Corrective Action Required
05/06/2004
MISC Fireplace NO PREVIOUS INSPECTIONS 03/24/04 - INSPECTED INTERIOR OF CHIMNEYS FOR 2 FIREPLACES IN MAIN AREA OF HOUSE DUE TO CONSTRUCTION UNABLE TO INSPECT THE OTHER FIREPLACES
Correction
Corrective Action Required
05/06/2004
MISC Permit UPGRADE - SHOW 2 - 200 AMP & 2 - 100 AMP PANELS OKAY TO INSULATE, OKAY TO ROCK
Correction
Resolved
05/06/2004
MISC See Text
Correction
Resolved
05/06/2004
MISC See Text
All Rough Inspection - Residential Failed 07/09/2004
Correction
Corrective Action Required
07/09/2004
R314.3 Stairway Headroom (IRC) STAIRWAY TO BASEMENT MEASURED 6'0" HEADROOM
Driveway Inspection Passed 08/25/2004
Correction
Resolved
08/25/2004
NONE None 6" DEPTH, GRAVEL BASE
Driveway Inspection Passed 08/25/2004
Sidewalk Inspection Passed 08/26/2004
Correction
Resolved
08/26/2004
NONE None 4' WIDE, 4" DEPTH, GRAVEL BASE, DBL ROW #4 REBAR PRIOR TO POURING: 1. INSTALL EXPANSION JOINT AT DRIVE APPROACH. 2. DRILL INTO APPROACH AND INSERT REBAR.
Sidewalk Inspection Passed 08/26/2004
Occupancy Inspection - Codes Residential Failed 09/13/2004
Correction
Corrective Action Required
09/13/2004
MISC Exterior Siding UNPROTECTED SHEETING EXPOSED
Correction
Corrective Action Required
09/13/2004
MISC Roof NOT FINISHED
Correction
Corrective Action Required
09/13/2004
LSCO 7-914 Handrails (IRC) INSTALL GUARDRAILS & HANDRAILS Deck
Correction
Corrective Action Required
09/13/2004
LSCO 7-160K Reinspection Fee FROM ALL ROUGH INSPECTION
Correction
Corrective Action Required
09/13/2004
MISC Fireplaces PROVIDE LETTER FROM SUB CONTRACTOR DETAILING INSTALLATION. WHEN INSPECTION WAS REQUESTED WORK WAS AT A STEAGE THAT PREVENTED INSPECTION.
Correction
Corrective Action Required
09/13/2004
LSCO 7-955 Kitchen Receptacles (IRC) OUTLET - WEST SIDE OF COOKTOP - NOT GFCI PROTECTED Kitchen
Correction
Corrective Action Required
09/13/2004
E3802.1 Bathroom GFCI Receptacles (IRC) WILL NOT TRIP Loft - Bathroom
Correction
Corrective Action Required
09/13/2004
LSCO 7-914 Handrails (IRC) HANDRAILS AND GUARDRAILS TO LOFT AND TO BASEMENT NOT FINISHED Interior
Correction
Corrective Action Required
09/13/2004
E3802.3 Outdoor GFCI Receptacles (IRC) OUTLET BOX CAPPED Front
Correction
Corrective Action Required
09/13/2004
MISC See Comment DO NOT OCCUPY OR USE AS MODEL ROOM
Correction
Corrective Action Required
09/13/2004
R401.3 Grading (IRC) 1. REMOVE CONSTRUCTION DEBRIS 2. PROVIDE FINAL GRADE 3. INSTALL SOD/SEED/EROSION CONTROL 4. INSTALL GUTTERING AND DOWNSPOUTS 5. INSTALL MINIMUM OF 36" SPLASHBLOCKS AT DOWNSPOUTS
Correction
Corrective Action Required
09/13/2004
E3509.7 Metal Gas Piping Bonding (IRC) Basement
Correction
Corrective Action Required
09/13/2004
M1801.11 Multiple Appliance Venting Systems (IRC) SINGLE WALL MULTIPLE VENT CONNECTORS - WATER HEATER/FURNACE Basement
Correction
Corrective Action Required
09/13/2004
MISC Support Columns INSTALL ANCHOR BOLTS Basement
Gas Piping Inspection - Residential Passed 09/13/2004
Correction
Resolved
09/13/2004
G2418.2 Gas Piping--Drips (IRC) NO LONGER REQUIRED TO BE ACCESSIBLE
All Rough Inspection - Residential Passed 09/13/2004
Correction
Resolved
09/13/2004
MISC Fireplace
Correction
Resolved
09/13/2004
MISC Permit
Correction
Resolved
09/13/2004
LSCO 7-160K Reinspection Fee
Correction
Resolved
09/13/2004
R314.3 Stairway Headroom (IRC)
Occupancy Inspection - Codes Residential Failed 09/16/2004
Correction
Resolved
09/16/2004
MISC Roof
Correction
Partial Correction
09/16/2004
LSCO 7-914 Handrails (IRC) DOORS BLOCKED
Correction
Resolved
09/16/2004
LSCO 7-955 Kitchen Receptacles (IRC)
Correction
Resolved
09/16/2004
E3802.1 Bathroom GFCI Receptacles (IRC)
Correction
Resolved
09/16/2004
LSCO 7-914 Handrails (IRC)
Correction
Resolved
09/16/2004
E3802.3 Outdoor GFCI Receptacles (IRC)
Correction
Resolved
09/16/2004
E3509.7 Metal Gas Piping Bonding (IRC)
Correction
Corrective Action Required
09/16/2004
M1801.11 Multiple Appliance Venting Systems (IRC) SINGLE WALL MULTIPLE VENT CONNECTORS - WATER HEATER TO FURNACE Basement
Correction
Corrective Action Required
09/16/2004
MISC Support Columns INSTALL ANCHOR BOLTS Basement
Correction
Corrective Action Required
09/16/2004
MISC See Comment DO NOT OCCUPY OKAY TO USE AS A MODEL
Occupancy Inspection - Codes Residential Failed 10/07/2004
Correction
Corrective Action Required
10/07/2004
R401.3 Grading (IRC) 1. REMOVE CONSTRUCTION DEBRIS 2. PROVIDE FINAL GRADE 3. INSTALL SOD/SEED/EROSION CONTROL 4. INSTALL GUTTERING AND DOWNSPOUTS 5. INSTALL MINIMUM OF 36" SPLASHBLOCKS AT DOWNSPOUTS
Correction
Corrective Action Required
10/07/2004
MISC Exterior Siding UNPROTECTED SHEETING EXPOSED
Correction
Corrective Action Required
10/07/2004
LSCO 7-914 Handrails (IRC) GUARD RAILS MUST BE INSTALLED ON ANT DECK OR PORTION OF DECK 30" OR GREATER FROM GRADE.
Correction
Corrective Action Required
10/07/2004
MISC Fireplaces PROVIDE LETTER FROM SUB CONTRACTOR DETAILING INSTALLATION. WHEN INSPECTION WAS REQUESTED WORK WAS AT A STEAGE THAT PREVENTED INSPECTION.
Correction
Corrective Action Required
10/07/2004
MISC See Comment DO NOT OCCUPY OKAY TO USE AS A MODEL
Occupancy Inspection - Codes Residential Failed 11/15/2004
Correction
Resolved
11/15/2004
R401.3 Grading (IRC)
Correction
Resolved
11/15/2004
MISC Exterior Siding
Correction
Corrective Action Required
11/15/2004
LSCO 7-914 Handrails (IRC) GUARD RAILS MUST BE INSTALLED ON ANY DECK OR PORTION OF DECK 30" OR GREATER FROM GRADE. Deck Lower
Correction
Corrective Action Required
11/15/2004
MISC See Comment DO NOT OCCUPY OKAY TO USE AS A MODEL
Correction
Corrective Action Required
11/15/2004
Misc- No Access Provided HOUSE LOCKED
Occupancy Inspection - Codes Residential Failed 11/16/2004
Correction
Corrective Action Required
11/16/2004
LSCO 7-914 Handrails (IRC) GUARD RAILS MUST BE INSTALLED ON ANY DECK OR PORTION OF DECK 30" OR GREATER FROM GRADE. Deck Upper,Lower
Correction
Resolved
11/16/2004
M1801.11 Multiple Appliance Venting Systems (IRC)
Correction
Resolved
11/16/2004
MISC Support Columns
Correction
Resolved
11/16/2004
MISC See Comment
Correction
Resolved
11/16/2004
Misc- No Access Provided
Occupancy Inspection - Codes Residential Passed 12/20/2004
Correction
Resolved
12/20/2004
LSCO 7-914 Handrails (IRC)
Correction
Resolved
12/20/2004
LSCO 7-160K Reinspection Fee
Correction
Resolved
12/20/2004
MISC Fireplaces
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home