Permit Application Status

B0202253


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0202253
Building Permit - Commercial
Final Completion
CITY OF LEES SUMMIT
PARTIAL COMMERCIAL
COMMUNITY CENTER FOUNDATION & UNDERSLAB
12/30/2002
12/30/2002
06/28/2003
04/05/2004
Locations
Contacts
BARSTO CONSTRICTION INC, Address:1601 IRON STREET  
HOLLIS & MILLER GROUP, INC, Address:220 NW EXECUTIVE WAY  
CITY OF LEES SUMMIT, Address:PO BOX 1600  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 06/28/2003 10/29/2010
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - 2000 IBC 1704.1.2 - Special inspectors shall keep records of inspections. The special inspector shall furnish inspection reports to the building official, and to the registered design professional in responsible charge. Reports shall indicate that work inspected was done in conformance to approved construction documents. Discrepancies shall be brought to the immediate attention of the contractor for correction. If the discrepancies are not corrected, the discrepancies shall be brought to the attention of the building official and the registered design professional in responsible charge prior to the completion of that phase of the work. A final report of inspections documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted periodically at a frequency agreed upon by the permit applicant and the building official prior to the start of work.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - This is an "at risk permit". Construction shall be in accordance with plans submitted for permit approval. The applicant understands that issuance of this permit does not guaranty issuance of a full permit.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $2,852.00 $2,852.00 Paid 12/30/2002
24 BLDG Plan Check Fees $67.50 $67.50 Paid 12/30/2002
25 Electrical Permit Fee $15.00 $15.00 Paid 12/30/2002
25 Plumbing Permit Fees $15.00 $15.00 Paid 12/30/2002
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Commercial Partial 01/21/2003
Correction
Partial Correction
01/21/2003
None 8 PIERS AROUND POOL EQPT. ROOM APPROVED.
Piers/Caissons Inspection - Commercial Partial 01/27/2003
Correction
Partial Correction
01/27/2003
None PIER 652, 658, 659 AND 663 OBSERVED. SIZE, REINFORCING AND CONCRETE COMPLIANT WITH APPROVED PLANS.
Piers/Caissons Inspection - Commercial Partial 01/28/2003
Correction
Partial Correction
01/28/2003
None PIERS 623, 625, 641, 643, 644, 652, 658, 659 AND 663 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Piers/Caissons Inspection - Commercial Partial 01/29/2003
Correction
Partial Correction
01/29/2003
None PIERS 551, 553, 554, 560, 561 AND 562 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Erosion Control Inspection Residential Passed 01/30/2003
Piers/Caissons Inspection - Commercial Partial 01/30/2003
Correction
Partial Correction
01/30/2003
None PIERS 551, 553, 554, 560, 561 AND 562 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Correction
Partial Correction
01/30/2003
None PIERS 555, 556 AND 557 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Piers/Caissons Inspection - Commercial Partial 02/03/2003
Correction
Partial Correction
02/03/2003
None PIERS FOR ELEVATOR SHAFT FOUNDATION APPROVED.
Piers/Caissons Inspection - Commercial Partial 02/04/2003
Correction
Partial Correction
02/04/2003
None PIERS 675, 676, 677, 678, 679 AND 680 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Piers/Caissons Inspection - Commercial Partial 02/05/2003
Correction
Partial Correction
02/05/2003
None OBSERVED PIERS 573, 574, 575. COMPLIANT WITH APPROVED PLANS.
Piers/Caissons Inspection - Commercial Partial 02/10/2003
Correction
Partial Correction
02/10/2003
None OBSERVED PIERS 581, 586, 587, 605, 606 & 613. COMPLIANT WITH PLANS
Correction
Partial Correction
02/10/2003
None OBSERVED PIERS 579, 696, 697, 698, 699. COMPLIANT WITH APPROVED PLANS
Piers/Caissons Inspection - Commercial Partial 02/11/2003
Correction
Partial Correction
02/11/2003
None OBSERVED 558 & 559, 578 STEEL NOT INSTALLED. COMPLIANT WITH APPROVED PLANS
Correction
Partial Correction
02/11/2003
None OBSERVED 608, 609, 634, 635, 637, 683, 684, 645. NO STEEL IN PLACE.
Foundation Inspection - Commercial Partial 02/21/2003
Correction
Partial Correction
02/21/2003
Rebar PAGE S3 - LINE Q, LINE 8.8 TO LINE 7. LINE 7 FROM Q TO A POINT APPROX. P.1. LINE 8.8 FROM Q TO A POINT APPROX. 2/3 OF DISTANCE TO LINE P. PAGE S2 - LINE B FROM APPROX. 10` FROM EACH END
Foundation Inspection - Commercial Partial 02/27/2003
Correction
Corrective Action Required
02/27/2003
Not Ready Elevator Pit
Footing Inspection - Commercial Partial 03/03/2003
Correction
Partial Correction
03/03/2003
None STRUCTURAL ENGINEER MEL PROTCOR DEFINED - S8/1 "CENTER OF END SPANS" AS `HALF WAY BETWEEN END OF A SPAN & 1st PIER FROM END OF SPAN`. S2 - LINE 9 FROM LINE B TO APPROX 5` NORTH OF LINE C. LINE 10 TO TIE IN WITH LINE 9 AT LINE C.
Footing Inspection - Commercial Partial 03/04/2003
Correction
Partial Correction
03/04/2003
Not Ready SHEET S2 - LINE 9 FROM LINE C TO LINE E. LINE D & LINE K FROM LINE 9 TO LINE 10. LINE 10 FROM LINE D TO LINE K.
Foundation Inspection - Commercial Partial 03/06/2003
Correction
Resolved
03/06/2003
Not Ready APPROVED - AS PER REVISED PLANS Elevator Pit
Correction
Partial Correction
03/06/2003
None 32, 33, 36, 39, 41, 42, 43, 44, 45, 46. Columns
Footing Inspection - Commercial Partial 03/07/2003
Correction
Partial Correction
03/07/2003
None SHEET S3 - LINE 9 FROM LINE K TO SITE OF DBL DOORS AT SOUTH END OF LINE 9
Correction
Partial Correction
03/07/2003
None SHEET S3 - LINE 9 - COMPLETED, LINE 8.8 - COMPLETED, LINE P FROM LINE 9 TO LINE 8.2
Underground Electrical Inspection - Commercial Partial 03/11/2003
Correction
Partial Correction
03/11/2003
None GROUNDING OF PIER AND GR. BEAM REINFORCING AT Q LINE APPROVED
Foundation Inspection - Commercial Partial 03/11/2003
Correction
Partial Correction
03/11/2003
None GR. BEAMS FROM L-7 TO P-7 AND Q-3 TO Q-7 APPROVED
Footing Inspection - Commercial Failed 03/11/2003
Correction
Corrective Action Required
03/11/2003
Not Ready DISCREPANCIES IN APPROVED PLANS. REQUIRE ENGINEER`S DETERMINATION.
Foundation Inspection - Commercial Partial 03/12/2003
Correction
Partial Correction
03/12/2003
None SHEET S2 - # 37, 38, 40, 47, 8, 9, 17, 23, 28 Columns
Underslab Plumbing Inspection - Commercial Partial 03/12/2003
Correction
Partial Correction
03/12/2003
None P4 - DETAIL #4 - SUPP. INSTR #05 - 4" LINE & FLOOR DRAINS FOR WOMEN`S LOCKER ROOM TO A POINT APPROX 6`. P1.0 - 12" DRAIN @ LINE 9 FROM LINE B TO LINE E TO LINE H. LINE UPSIZED FROM 10" TO 12"
Footing Inspection - Commercial Partial 03/12/2003
Correction
Partial Correction
03/12/2003
None SHEET S3 LINE 3 FROM LINE Q TO LINE L.
Underslab Plumbing Inspection - Commercial Partial 03/14/2003
Correction
Partial Correction
03/14/2003
None P4.0 DET 4 RESTROOM PACKAGE/FD PACKAGE E THRU J1.1 8.5 SO TO 9.5 BALANCE OF 12" RD TO J1.1
Underground Plumbing Inspection - Commercial Failed 03/17/2003
Correction
Partial Correction
03/17/2003
BELOW OK TO COVER 120 LIN. FT. OF 12 IN. ROOF STORM FROM COL. LINE E TO WEST OF B LINE..
Footing Inspection - Commercial Partial 03/17/2003
Correction
Partial Correction
03/17/2003
BELOW OK TO POUR 46 FT. OF GRADE BEAM AT COL. M-N,1-3.
Footing Inspection - Commercial Partial 03/18/2003
Correction
Corrective Action Required
03/18/2003
BELOW 71 FT OF FTG. OK TO POUR - 2 LINE, 20 FT. J LINE, L LINE 5 FT. OF 3 LINE
Piers/Caissons Inspection - Commercial Partial 03/18/2003
Correction
Partial Correction
03/18/2003
None OK TO POUR COL. 24. 25, 29, 30, 31, 34, 35
Foundation Inspection - Commercial Partial 03/24/2003
Correction
Partial Correction
03/24/2003
None sht s2 col 10, 15, 16, 18, 19
Underslab Plumbing Inspection - Commercial Partial 03/24/2003
Correction
Partial Correction
03/24/2003
None 4 in main east line 80 ft north to approx 5 col east 20 ft ok to cover
Underslab Electrical Inspection - Commercial Partial 03/24/2003
Correction
Partial Correction
03/24/2003
None 2 3in main 10 ft from bldg 2 1 in lighting 40 ft north ok to cover
Underslab Plumbing Inspection - Commercial Partial 03/25/2003
Correction
Partial Correction
03/25/2003
None DET. 2 P4.0 APPROVED
Underslab Electrical Inspection - Commercial Partial 03/25/2003
Correction
Partial Correction
03/25/2003
None UGC IN ELECTRICAL ROOM APPROVED 3 2IN CONDUIT INCOMPLETE TO SOUTH.
Footing Inspection - Commercial Partial 03/25/2003
Correction
Partial Correction
03/25/2003
BELOW 71 FT OF FTG. OK TO POUR - 2 LINE, 20 FT. J LINE, L LINE 5 FT. OF 3 LINE
Correction
Partial Correction
03/25/2003
None S3 NORTH FOOTING K LINE WEST TO D.2
Foundation Inspection - Commercial Partial 03/26/2003
Correction
Partial Correction
03/26/2003
CIP CONC COLUMNS 10, 12, 13, 14, 20, 21, 22, 25, 27, 37, 47 OKTO POUR WHEN READY COLUMN #'s 3, 4, 5, 6, 10
Footing Inspection - Commercial Partial 03/26/2003
Correction
Partial Correction
03/26/2003
GRADE BEAM PARTIAL OK TO POUR WHEN READY ON (7) FROM (B) TO (E) + WALLS OF FIREPLACE AREA
Underslab Electrical Inspection - Commercial Partial 04/01/2003
Correction
Partial Correction
04/01/2003
None AS BUILT ONLY - NO APPROVED PLANS - BETWEEN COLUMN 46 & COLUMN 44 - 3 2" PVC CONDUIT, 2 OF THE 2" CONDUIT RUNS TO COLUMN 42. NONE STUBBED UP. TELEPHONE DBL 4" PVC CONDUIT FROM APPROX D.2 TO G ON LINE 7.5
Foundation Inspection - Commercial Partial 04/01/2003
Correction
Partial Correction
04/01/2003
None ALL COLUMNS APPROVED - EXCEPT 48, 49, 52, 53 Columns
Underslab Plumbing Inspection - Commercial Partial 04/02/2003
Correction
Partial Correction
04/02/2003
None P1.1 - 8" LINE (SOUTH OF LINE L) TO LINE 7. 8" AT LINE 7 FROM L.1 TO LINE N. 4" LINE FROM J.1 TO A POINT 20` SOUTH OF 2" CLEANOUT AT LINE N.
Underslab Electrical Inspection - Commercial Partial 04/02/2003
Correction
Partial Correction
04/02/2003
None S2 -NO PLANS - AS BUILT - 2 3/4" PVC AT LINE 8.9 FROM LINES C TO E. COVER AT OWN RISK
Footing Inspection - Commercial Partial 04/03/2003
Correction
Partial Correction
04/03/2003
None S3 - PAD @ P BETWEEN 7.5 & 8.2
Foundation Inspection - Commercial Partial 04/03/2003
Correction
Partial Correction
04/03/2003
CIP CONC COLUMNS 10, 12, 13, 14, 20, 21, 22, 25, 27, 37, 47, 1 OKTO POUR WHEN READY COLUMN #'s 3, 4, 5, 6, 10
Correction
Partial Correction
04/03/2003
None ALL COLUMNS APPROVED - EXCEPT 2,48, 49, 52, 53 Columns
Correction
Partial Correction
04/03/2003
None COLUMN 2
Foundation Inspection - Commercial Partial 04/08/2003
Correction
Partial Correction
04/08/2003
None S3 - FOUNDATION WALLS - OKAY TO POUR Pool Equipment Pit
Foundation Inspection - Commercial Partial 04/14/2003
Correction
Partial Correction
04/14/2003
None # 48,49,52 & 53 - PER S8-X1 OF PROJECT MANUAL 1 OF 3. COLUMN CONSTRUCTION NOT LISTED ON APPROVED PLANS. POUR AT OWN RISK Columns
Underslab Plumbing Inspection - Commercial Partial 04/30/2003
Correction
Partial Correction
04/30/2003
None P1.1 6" WASTE LINE - LINE P.5, FROM 1 TO 8.5. FLOOR DRAINS IN ROOM 114
Underslab Plumbing Inspection - Commercial Partial 05/02/2003
Correction
Partial Correction
05/02/2003
None P1.1 6" STORM LINES RUNNING EAST/WEST AT LINE P.5 & TIE IN TO 10" STORM LINE AT LINE 7
Foundation Inspection - Commercial Partial 05/06/2003
Correction
Partial Correction
05/06/2003
Columns SHEET S4 - COLUMNS 10, 15, 16, 18, 19, 32
Underslab Plumbing Inspection - Commercial Partial 05/06/2003
Correction
Partial Correction
05/06/2003
None SHEET P1.1 - KITCHEN
Foundation Inspection - Commercial Partial 05/09/2003
Correction
Resolved
05/09/2003
None SHEET S4 - #`s 29,30,31,41,42,43,44 Columns
Foundation Inspection - Commercial Partial 05/13/2003
Correction
Partial Correction
05/13/2003
None SHEET S4 - 7, 12, 14, 21, 22, 27, APPROVED. SHEET S4 - 2, 3, 4, 5 CHANGES MADE BY ENGINEER. LTR SHOWING CHANGES. COLUMNS TIED PER CHANGES, NOT INSTALLED. SPL INSPECT. TO INSPECT PLACEMENT. SUBMIT TO CITY FOR APPROVAL. POUR AT OWN RISK. Columns
Underslab Electrical Inspection - Commercial Partial 05/28/2003
Correction
Partial Correction
05/28/2003
None NO APPROVED PLANS. 6 - 3" PVC FROM TRANSFORMER TO MDP. COVER AT OWN RISK.
Piers/Caissons Inspection - Commercial Partial 08/15/2003
Correction
Partial Correction
08/15/2003
None POOL SLIDE: AS PER MANUFACTURER`S INSTRUCTIONS EXCEPT PIER T-1
Pool Steel/Bonding - Commercial Partial 08/15/2003
Correction
Partial Correction
08/15/2003
None DRAIN INLETS & PLAY FEATURE IN MIDDLE OF POOL TO STEEL REINFORCEMENT
Foundation Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
Rebar PAGE S3 - LINE Q, LINE 8.8 TO LINE 7. LINE 7 FROM Q TO A POINT APPROX. P.1. LINE 8.8 FROM Q TO A POINT APPROX. 2/3 OF DISTANCE TO LINE P. PAGE S2 - LINE B FROM APPROX. 10` FROM EACH END
Correction
Resolved
02/03/2004
Not Ready APPROVED - AS PER REVISED PLANS Elevator Pit
Correction
Resolved
02/03/2004
None 32, 33, 36, 39, 41, 42, 43, 44, 45, 46. Columns
Correction
Resolved
02/03/2004
None GR. BEAMS FROM L-7 TO P-7 AND Q-3 TO Q-7 APPROVED
Correction
Resolved
02/03/2004
None SHEET S2 - # 37, 38, 40, 47, 8, 9, 17, 23, 28 Columns
Correction
Resolved
02/03/2004
None sht s2 col 10, 15, 16, 18, 19
Correction
Resolved
02/03/2004
CIP CONC COLUMNS 10, 12, 13, 14, 20, 21, 22, 25, 27, 37, 47, 1 OKTO POUR WHEN READY COLUMN #'s 3, 4, 5, 6, 10
Correction
Resolved
02/03/2004
None ALL COLUMNS APPROVED - EXCEPT 2,48, 49, 52, 53 Columns
Correction
Resolved
02/03/2004
None COLUMN 2
Correction
Resolved
02/03/2004
None S3 - FOUNDATION WALLS - OKAY TO POUR Pool Equipment Pit
Correction
Resolved
02/03/2004
None # 48,49,52 & 53 - PER S8-X1 OF PROJECT MANUAL 1 OF 3. COLUMN CONSTRUCTION NOT LISTED ON APPROVED PLANS. POUR AT OWN RISK Columns
Correction
Resolved
02/03/2004
None SHEET S4 - 7, 12, 14, 21, 22, 27, APPROVED. SHEET S4 - 2, 3, 4, 5 CHANGES MADE BY ENGINEER. LTR SHOWING CHANGES. COLUMNS TIED PER CHANGES, NOT INSTALLED. SPL INSPECT. TO INSPECT PLACEMENT. SUBMIT TO CITY FOR APPROVAL. POUR AT OWN RISK. Columns
Correction
Resolved
02/03/2004
Columns SHEET S4 - COLUMNS 10, 15, 16, 18, 19, 32
Underground Electrical Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
None GROUNDING OF PIER AND GR. BEAM REINFORCING AT Q LINE APPROVED
Special Inspections Passed 02/03/2004
Correction
Resolved
02/03/2004
None Received 3 February 2004.
Pool Steel/Bonding - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
None DRAIN INLETS & PLAY FEATURE IN MIDDLE OF POOL TO STEEL REINFORCEMENT
Final Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
None Close Permit
Footing Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
None STRUCTURAL ENGINEER MEL PROTCOR DEFINED - S8/1 "CENTER OF END SPANS" AS `HALF WAY BETWEEN END OF A SPAN & 1st PIER FROM END OF SPAN`. S2 - LINE 9 FROM LINE B TO APPROX 5` NORTH OF LINE C. LINE 10 TO TIE IN WITH LINE 9 AT LINE C.
Correction
Resolved
02/03/2004
Not Ready SHEET S2 - LINE 9 FROM LINE C TO LINE E. LINE D & LINE K FROM LINE 9 TO LINE 10. LINE 10 FROM LINE D TO LINE K.
Correction
Resolved
02/03/2004
None SHEET S3 - LINE 9 FROM LINE K TO SITE OF DBL DOORS AT SOUTH END OF LINE 9
Correction
Resolved
02/03/2004
None SHEET S3 - LINE 9 - COMPLETED, LINE 8.8 - COMPLETED, LINE P FROM LINE 9 TO LINE 8.2
Correction
Resolved
02/03/2004
None SHEET S3 LINE 3 FROM LINE Q TO LINE L.
Correction
Resolved
02/03/2004
BELOW OK TO POUR 46 FT. OF GRADE BEAM AT COL. M-N,1-3.
Correction
Resolved
02/03/2004
BELOW 71 FT OF FTG. OK TO POUR - 2 LINE, 20 FT. J LINE, L LINE 5 FT. OF 3 LINE
Correction
Resolved
02/03/2004
None S3 NORTH FOOTING K LINE WEST TO D.2
Correction
Resolved
02/03/2004
GRADE BEAM PARTIAL OK TO POUR WHEN READY ON (7) FROM (B) TO (E) + WALLS OF FIREPLACE AREA
Correction
Resolved
02/03/2004
None S3 - PAD @ P BETWEEN 7.5 & 8.2
Piers/Caissons Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
None 8 PIERS AROUND POOL EQPT. ROOM APPROVED.
Correction
Resolved
02/03/2004
None PIERS 623, 625, 641, 643, 644, 652, 658, 659 AND 663 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Correction
Resolved
02/03/2004
None PIERS 551, 553, 554, 560, 561 AND 562 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Correction
Resolved
02/03/2004
None PIERS 555, 556 AND 557 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Correction
Resolved
02/03/2004
None PIERS FOR ELEVATOR SHAFT FOUNDATION APPROVED.
Correction
Resolved
02/03/2004
None PIERS 675, 676, 677, 678, 679 AND 680 OBSERVED. COMPLIANT WITH APPROVED PLANS.
Correction
Resolved
02/03/2004
None OBSERVED PIERS 573, 574, 575. COMPLIANT WITH APPROVED PLANS.
Correction
Resolved
02/03/2004
None OBSERVED PIERS 581, 586, 587, 605, 606 & 613. COMPLIANT WITH PLANS
Correction
Resolved
02/03/2004
None OBSERVED PIERS 579, 696, 697, 698, 699. COMPLIANT WITH APPROVED PLANS
Correction
Resolved
02/03/2004
None OBSERVED 558 & 559, 578 STEEL NOT INSTALLED. COMPLIANT WITH APPROVED PLANS
Correction
Resolved
02/03/2004
None OK TO POUR COL. 24. 25, 29, 30, 31, 34, 35
Correction
Resolved
02/03/2004
None POOL SLIDE: AS PER MANUFACTURER`S INSTRUCTIONS EXCEPT PIER T-1
Correction
Resolved
02/03/2004
None OBSERVED 608, 609, 634, 635, 637, 683, 684, 645. NO STEEL IN PLACE.
Underslab Plumbing Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
None P4 - DETAIL #4 - SUPP. INSTR #05 - 4" LINE & FLOOR DRAINS FOR WOMEN`S LOCKER ROOM TO A POINT APPROX 6`. P1.0 - 12" DRAIN @ LINE 9 FROM LINE B TO LINE E TO LINE H. LINE UPSIZED FROM 10" TO 12"
Correction
Resolved
02/03/2004
None P4.0 DET 4 RESTROOM PACKAGE/FD PACKAGE E THRU J1.1 8.5 SO TO 9.5 BALANCE OF 12" RD TO J1.1
Correction
Resolved
02/03/2004
None 4 in main east line 80 ft north to approx 5 col east 20 ft ok to cover
Correction
Resolved
02/03/2004
None DET. 2 P4.0 APPROVED
Correction
Resolved
02/03/2004
None P1.1 - 8" LINE (SOUTH OF LINE L) TO LINE 7. 8" AT LINE 7 FROM L.1 TO LINE N. 4" LINE FROM J.1 TO A POINT 20` SOUTH OF 2" CLEANOUT AT LINE N.
Correction
Resolved
02/03/2004
None P1.1 6" WASTE LINE - LINE P.5, FROM 1 TO 8.5. FLOOR DRAINS IN ROOM 114
Correction
Resolved
02/03/2004
None P1.1 6" STORM LINES RUNNING EAST/WEST AT LINE P.5 & TIE IN TO 10" STORM LINE AT LINE 7
Correction
Resolved
02/03/2004
None SHEET P1.1 - KITCHEN
Underslab Electrical Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
None UGC IN ELECTRICAL ROOM APPROVED 3 2IN CONDUIT INCOMPLETE TO SOUTH.
Correction
Resolved
02/03/2004
None AS BUILT ONLY - NO APPROVED PLANS - BETWEEN COLUMN 46 & COLUMN 44 - 3 2" PVC CONDUIT, 2 OF THE 2" CONDUIT RUNS TO COLUMN 42. NONE STUBBED UP. TELEPHONE DBL 4" PVC CONDUIT FROM APPROX D.2 TO G ON LINE 7.5
Correction
Resolved
02/03/2004
None S2 -NO PLANS - AS BUILT - 2 3/4" PVC AT LINE 8.9 FROM LINES C TO E. COVER AT OWN RISK
Correction
Resolved
02/03/2004
None NO APPROVED PLANS. 6 - 3" PVC FROM TRANSFORMER TO MDP. COVER AT OWN RISK.
Underground Plumbing Inspection - Commercial Passed 02/03/2004
Correction
Resolved
02/03/2004
BELOW OK TO COVER 120 LIN. FT. OF 12 IN. ROOF STORM FROM COL. LINE E TO WEST OF B LINE..
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home