Permit Application Status

B0202246


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0202246
Building Permit - Commercial
Certificate of Occupancy
WENDYS OLD FASHIONED HAMBURGERS
NEW COMMERCIAL
NEW FASTFOOD REST
12/26/2002
02/13/2003
08/12/2003
09/23/2003
Locations
Contacts
FALLCREEK CONSTRUCTION, INC, Address:8181 INDUSTRIAL PLACE, SUITE A  
SHAW, HOFSTRA, & ASSOCIATES, Address:1717 OAK STREET  
WENDYS OLD FASHIONED HAMBURGERS, Address:1155 PERIMETER CENTER WEST  
MEL-ROSE BEACH INC, Address:4810 S ARROWHEAD DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 06/24/2003 10/29/2010
Correction

CA - A full building permit will not be issued until the Final Development Plan has been approved.
Correction

CA - No building permits will be issued until the development receives a letter of substantial completion from the Public Works Department.
Correction

CA - The City will not issue any type of certificate of occupancy until until all itemes required for the development have been completed and a letter of substaintal completion has been issued.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - ANSI A117.1-1998 404.2.7 - Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Such hardware shall be 34 inches minimum and 48 inches maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

CA - The design on the retaining wall was not provided with the permit application.
Correction

CA - I am unable to find detailed information on the ladder to the roof access hatch.
Correction

CA - The shelves in room 104 appear to overlap the ladder to the roof.
Correction

CA - I am unable to locate the design loads used for this structure.
Correction

CA - I am unable to locate information on the materials to be used in the plumbing installation.
Correction

CA - I am unable to locate information on the rated duct systems for the hoods.
Correction

CA - I am unable to locate information on the type of materials to be used for the electrical installation.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the code official.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. The plans and specifications shall bear a State of Missouri licensed engineers seal. This includes fire sprinkler systems, grease hood and duct suppression systems as well as other fire suppression system.
Correction

Fire Department: Fire detection, alarm and extinguishing systems shall be maintained in an op-erative condition at all times, and shall be replaced or repaired where defective.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - 2000 IMC 403.3 - Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and the occupant load or other perameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less then the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

CA - For the Health Department inspection contact Bob Thomas with the Jackson County Public Works Department at 816-881-4530. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

CA - 2000 IBC 1704.1 - Where application is made for construction as described in this section, the owner or the registered design professional in responsible charge acting as the owner's agent shall employ one or more special inspectors to provide inspections during construction on the types of work listed under Section 1704. The special inspecor shall be a qualified person who shall demonstrate competence, to the satisfaction of the building official, for inspection of the the particular type of construction or operation requiring special inspection.
Correction

CA - 2000 IBC 1003.3.1.4 - Floor Elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal.
Correction

CA - 2000 IBC 1003.3.1.6 - Thresholds. Thresholds at doorways shall not exceed 0.75 inch in height for sliding doors serving dwelling units or 0.5 inch for other doors. Raised thresholds and floor level changes greater then 0.25 inch at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope).
Correction

CA - 2000 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as devined in Section 2406.2 shall pass the test requirements of CPSC 16 CFR 1201, listed in Chapter 35. Glazing shall comply with the CSPC 16 CFR, Part 1201 criteria for Category I or Category II as indicated in Table 2406.1.
Correction

CA - 2000 IBC 1003.2.11.2 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency system shall automatically illuminate all of the follow areas: 1. Exit access corridors, passageways, and aisles in rooms and spaces which require two or more means of egress. 2. Exit access corridors and exit stairways located in buildings required to have two or more exits. 3. Interior exit discharge elements, as permitted in Section 1006.1, in buildings required to have two or more exits. 4. The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits.
Correction

CA - 1999 NEC 250-104(b) - Metal gas piping. Each aboveground portion of a gas piping system upstream from the equipment shutoff valve shall be electrically continuous and bonded to the grounding electrode system.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Correction

CA - 2000 IMC 507.2 - Where required. A Type I or Type II hood shall be installed at or above all commercial food heat-processing appliances. A Type II hood shall be installed above commercial dishwashing machines.
Correction

CA - 2000 IPC 608.16.1 - Beverage dispensers. The water supply connection to carbonated beverage dispensers shall be protected against backflow by a double check valve with an intermediate atmospheric vent conforming to ASSE 1012 or ASSE 1022. The double check valve with an intermediate atmospheric vent device and the piping downstream therefrom shall not be affected by carbon dioxide gas. Secondary protection in the form of a dual check valve conforming to ASSE 1032 shall be installed on the beverage-dispensing equipment.
Correction

CA - 2000 IPC 308.5 - Pipe shall be supported in accordance with Table 308.5.
Correction

CA - 2000 IPC 312.1 - Required tests. The permit holder shall make the applicable test prescribed in Sections 312.2 through 312.9 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain if the pressure has reached all parts of the system. Note: Testing of the plumbing system is not required to be witnessed by the Codes Administration Staff with the exception of gas piping.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $1,277.00 $1,277.00 Paid 02/13/2003
24 BLDG Plan Check Fees $41.25 $41.25 Paid 02/13/2003
25 Electrical Permit Fee $222.69 $222.69 Paid 02/13/2003
25 Mechanical Permit Fees $82.00 $82.00 Paid 02/13/2003
25 Plumbing Permit Fees $105.50 $105.50 Paid 02/13/2003
84 Water Meters $600.00 $600.00 Paid 02/13/2003
85 Water Taps $6,835.00 $6,835.00 Paid 02/13/2003
89 Sewer Tap Fees $390.00 $390.00 Paid 02/13/2003
Right of Way Permit $35.00 $35.00 Paid 02/13/2003
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Passed 03/28/2003
Water Service Inspection Passed 04/01/2003
Correction
Resolved
04/01/2003
NONE > WATER SERVICE APPROVED PER PERMIT PRINTS UTILITY PLAN
Sewer Service Inspection Passed 04/01/2003
Correction
Resolved
04/01/2003
NONE > SEWER SERVICE APPROVED PER PERMIT PRINTS UTILITY PLAN
Water Service Inspection Passed 04/02/2003
Correction
Resolved
04/02/2003
FINAL PARTIAL SERVICE INSTALL METER/WELL INSTALLED TAP COMPLETED
Underslab Plumbing Inspection - Commercial Passed 04/03/2003
Correction
Resolved
04/03/2003
UNDER-FLOOR DWV & WATER PIPING OK TO COVER WHEN READY PER DRWG #15 EXCAVATED; LAID; JOINED SLOPED TO DRAIN
Underslab Electrical Inspection - Commercial Passed 04/03/2003
Correction
Resolved
04/03/2003
WORK IN PROGRESS
All Rough Inspection - Commercial Failed 04/24/2003
Correction
Corrective Action Required
04/24/2003
PIPING PROTECTION IPC 305.8; IRC P2603: INSTALL SHIELD PLATES AT STUDS & PLATES. AT DOUBLE TOP PLATES PLACE PROTECTION AT BOTH TOP & BOTTOM MEMBERS. WATER/DWV PIPING < 1 1/2" FROM FACE OF STUD / PLATE
All Rough Inspection - Commercial Partial 04/25/2003
Correction
Partial Correction
04/25/2003
PIPING PROTECTION IN-WALL SYSTEMS APPROVED OK TO COVER WHEN READY
Rough Mechanical Inspection - Commercial Partial 05/02/2003
Correction
Partial Correction
05/02/2003
None EXHAUST HOOD DUCT FAB/INSTALLATION COMPLIANT
Underground Electrical Inspection - Commercial Failed 05/13/2003
Correction
Corrective Action Required
05/13/2003
ELECTRICAL SERVICE CONDUIT BACKFILL CONSISTS OF CHUCKS OF CLAY NOT CONTINUOUSLY BEDDED IN TRENCH BEFORE BACKFILL
Underground Electrical Inspection - Commercial Passed 05/15/2003
Correction
Resolved
05/15/2003
ELECTRICAL SERVICE CONDUIT
Above Ceiling Inspection Partial 05/15/2003
Correction
Partial Correction
05/15/2003
ABOVE-CEILING SYSTEMS INCOMPLETE. OK TO PLACE CEILING TILE EXCEPT AT ELECT BOXES & SECTIONS OF WATER PIPE YET TO BE INSULATED. ELECT WIRE PULLING & TERM + WATER PIPE INSULATION
Underground Electrical Inspection - Commercial Passed 05/16/2003
Correction
Resolved
05/16/2003
SITE LIGHTING & SIGN POWER FEEDER CONDUIT OK TO COMPLETE AS OBSERVED. ENSURE ALL CONDUIT IS CONTINUOUSLY BEARING BEFORE MASS BACKFILL IS PLACED. TRENCH/LAY/COVER INSPECTED IN PROGRESS
Above Ceiling Inspection Passed 05/16/2003
Correction
Resolved
05/16/2003
ABOVE-CEILING SYSTEMS OK TO PLACE CEILING TILE WHEN READY
Electrical Service Inspection Passed 05/21/2003
Correction
Resolved
05/21/2003
NONE > APPROVED RELEASE SERVICE 225 AMP
Gas Piping Inspection - Commercial Passed 05/23/2003
Gas Service Inspection - Commercial Passed 05/23/2003
All Rough Inspection - Commercial Passed 06/05/2003
Correction
Resolved
06/05/2003
PIPING PROTECTION
Occupancy Inspection - Codes Commercial Failed 06/05/2003
Correction
Corrective Action Required
06/05/2003
OCCUPANCY STATUS DO NOT OCCUPY IBC 110.1: UNTIL APPROVED
Correction
Corrective Action Required
06/05/2003
PROXIMITY OF SO. PARKING LOT LIGHT TO POWER DISTRIBUTION LINES RECEIVE AQUILA APPROVAL AQUILA EXPECTED BY 6/6/03
Correction
Partial Correction
06/05/2003
Receive Water Utilities Approval TEST REPORT ORIGINALS RECEIPT TO BE CONFIRMED
Correction
Corrective Action Required
06/05/2003
Receive Public Works Approval BILL LYON 969-7324 REQUEST INSPECTION WHEN SITEWORK COMPLETED
Correction
Corrective Action Required
06/05/2003
Receive Planning & Development Approval TOM SCANNELL 969-7796 REQUEST INSPECTION BY P&D WHEN SITEWORK IS COMPLETE
Correction
Corrective Action Required
06/05/2003
Receive Fire Department approval FIRETRUCK ACCESS REQUIR'D FROM DOUGLAS STREET
Rough Mechanical Inspection - Commercial Passed 06/05/2003
Correction
Resolved
06/05/2003
None
Occupancy Inspection - Codes Commercial Failed 06/12/2003
Correction
Resolved
06/12/2003
Receive Water Utilities Approval PER JEFF WALTERS 6/11/03
Correction
Corrective Action Required
06/12/2003
Receive Planning & Development Approval 1) THE SITE MUST BE SODDED 2) THE FLOOD LIGHTS ATTACHED TO THE TOP OF THE PARKING LOT LIGHTS MUST BE REMOVED. THESE LIGHTS ARE PROHIBITED. 3) A SIGN PERMIT MUST BE ISSUED FOR THE BANNER. ONLY 1 BANNER PER LOT. THE SECOND BANNER MUST BE REMOVED. REQUEST REINSPECTION FROM TOM SCANNELL 969-7796
Occupancy Inspection - Codes Commercial Partial 06/13/2003
Correction
Resolved
06/13/2003
Receive Fire Department approval PER J EDEN 6/13/03
Correction
Corrective Action Required
06/13/2003
Receive Public Works Approval FOR REINSPECTION CONTACT BILL LYON @ 816-969-7324 2) INSTALL TRAFFIC SIGNAL PER DEVELOPMENT PLAN 3) SOD/SEED LOT TO PROVIDE PERMANENT EROSION CONTROL REPAIR/REPLACE BROKEN SIDEWALK SECTION @DOUGLAS
Correction
Resolved
06/13/2003
PROXIMITY OF SO. PARKING LOT LIGHT TO POWER DISTRIBUTION LINES LIGHT POLE RELOCATED PER AQUILA DIRECTION
Correction
Partial Correction
06/13/2003
OCCUPANCY STATUS SEE TEMPORARY OCCUPANCY
Erosion Control Inspection Residential Failed 06/13/2003
Correction
Corrective Action Required
06/13/2003
Erosion Control AT ALL SLOPES ADJACENT TO LOT & DRIVEWAYS. STORM INLETS ARE NOT PRESENTLY PROTECTED. PROVIDE MEASURES TO PREVENT EROSION @ LOT
Occupancy Inspection - Codes Commercial Partial 06/17/2003
Correction
Partial Correction
06/17/2003
OCCUPANCY STATUS SEE TEMPORARY OCCUPANCY
Correction
Corrective Action Required
06/17/2003
Receive Public Works Approval FOR REINSPECTION CONTACT BILL LYON @ 816-969-7324 2) INSTALL TRAFFIC SIGNAL PER DEVELOPMENT PLAN 3) SOD/SEED LOT TO PROVIDE PERMANENT EROSION CONTROL REPAIR/REPLACE BROKEN SIDEWALK SECTION @DOUGLAS
Correction
Corrective Action Required
06/17/2003
Receive Planning & Development Approval A SIGN PERMIT MUST BE ISSUED FOR THE BANNER. ONLY 1 BANNER PER LOT. THE SECOND BANNER MUST BE REMOVED. REQUEST REINSPECTION FROM TOM SCANNELL 969-7796
Erosion Control Inspection Residential Passed 06/18/2003
Correction
Resolved
06/18/2003
Erosion Control
Occupancy Inspection - Codes Commercial Partial 06/18/2003
Occupancy Inspection - Codes Commercial Partial 07/15/2003
Correction
Corrective Action Required
07/15/2003
Receive Public Works Approval 1) INSTALL TRAFFIC SIGNAL PER DEVELOPMENT PLAN 2) SOD/SEED LOT TO PROVIDE PERMANENT EROSION CONTROL FOR REINSPECTION CONTACT BILL LYON @ 816-969-7324
Occupancy Inspection - Codes Commercial Passed 09/22/2003
Correction
Resolved
09/22/2003
Receive Planning & Development Approval
Correction
Resolved
09/22/2003
Receive Public Works Approval PER K INGHAM 9/12/03 LTR
Correction
Resolved
09/22/2003
OCCUPANCY STATUS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home