Summary
B0202038
Building Permit - Commercial
Certificate of Occupancy
SAXTON KIRK J & MARTHA A
NEW COMMERCIAL
NEW COMMERCIAL BUILDING
11/20/2002
12/30/2002
06/28/2003
08/19/2003
Locations
Contacts
BRUCE BEST, AGMP (ARCHITECTURE GRAPHICS MANAGEME, Address:226 S DOUGLAS STREET  
WARD DEVELOPMENT COMPANY, Address:620 JEFFERSON  
HAMILTON, STERRETT, AND DOOLEY, Address:231 SW NOEL  
SAXTON KIRK J & MARTHA A, Address:618 SE 4TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 05/19/2003 10/29/2010
Correction

CA - The manufactured truss packages were not included with the permit application.
Correction

CA - The structural plans a 80 mph wind design load. The City of Lee's Summit requires a 90 mph 3 second gust.
Correction

CA - ANSI A117.1-1998 604.8.1 - Size. Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor mounted water closets, measured perpendicular to the rear wall.
Correction

CA - Details are not provided on the water heater.
Correction

CA - The materials for the waste and vent piping in the information located on Sheet P-1 is not consistant.
Correction

CA - The top of the electric panel schedules are cut off.
Correction

CA - The riser diagram indicates a ground to the pre-engineered metal building.
Correction

CA - If any portion of the retaining wall is greater than 4 feet in height measured from the bottom of the footing, an engineered design on the retaining wall will be required.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - 2000 IBC 1109.1 - Required accessible elements shall be identified by the International Symbol of Accessiblity at the locations listed in Section 1109.1. 1. Not applicable as the zoning ordinance is more restrictive. 2. Accessible passenger loading zones. 3. Accessible areas of refuge required by Section 1103.2.13.5. 4. Accessible rooms where multi single-user toilet or bathing rooms are clustered at a single location. 5. Accessible entrances where not all entrances are accessible. 6. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, shall be above the check-out aisle in the same location as the check-out aisle number or type of check-out identification. 7. Unisex toilet and bathing rooms. 8. Accessible dressing, fitting, and locker rooms where not all such rooms are accessible.
Correction

CA - 2000 IBC 1108.4 - Where kitchen, kitchenettes and wet bars are provided in accessible spaces or rooms, they shall be accessible in accordance with ICC/ANSI A117.1.
Correction

CA - 2000 IBC 1003.3.1.4 - Floor Elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal.
Correction

CA - 2000 IBC 1003.3.1.6 - Thresholds. Thresholds at doorways shall not exceed 0.75 inch in height for sliding doors serving dwelling units or 0.5 inch for other doors. Raised thresholds and floor level changes greater then 0.25 inch at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope).
Correction

CA - 2000 IBC 1004.3.2.1 - Corridor construction. Corridors shall be fire-resistance rated in accordance with Table 1004.3.2.1. The corridor walls required to be fire-resistance-rated shall comply with Section 708 for fire partitions.
Correction

CA - 2000 IBC 1003.2.11.2 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency system shall automatically illuminate all of the follow areas: 1. Exit access corridors, passageways, and aisles in rooms and spaces which require two or more means of egress. 2. Exit access corridors and exit stairways located in buildings required to have two or more exits. 3. Interior exit discharge elements, as permitted in Section 1006.1, in buildings required to have two or more exits. 4. The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits.
Correction

Fire Department; IFC 1003.3.1.8 Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department; Required means of egress components shall be maintained during construction and demolition.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - 2000 IMC 403.3 - Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and the occupant load or other perameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less then the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

CA - 2000 IMC 306.2 - Rooms containing appliances requiring access shall be provided with a door and an unobstructed passageway measuring not less than 36 inches wide and 80 inches high.
Correction

CA - 2000 IMC 701.2 - Combustion and dilution air required. Every room or space containing fuel-burning appliances shall be provided with combustion and dilution air as required by this code. Combustion and dilution air shall be provided in accordance with Section 702, 703, 704, 705, 706 or 707 or shall be provided by an approved engineered system. Direct vent appliances or equipment that do not draw combustion air from inside of the building are not required to be considered in the determination of the combustion and dilution air requirements. Combustion air requirements shall be determined based on the simultaneous operation of all fuel-burning appliances drawing combustion and dilution air from the room or space.
Correction

CA - 2000 IMC 304.8 - Clearances from grade. Equipment and appliances installed at grade level shall be supported on a level concrete slab or other approved material extending above adjoining grade or shall be suspended a minimum of 6 inches (152 mm) aboave adjoining grade.
Correction

CA - 2000 IPC 308.5 - Pipe shall be supported in accordance with Table 308.5.
Correction

CA - 2000 IPC 312.1 - Required tests. The permit holder shall make the applicable test prescribed in Sections 312.2 through 312.9 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain if the pressure has reached all parts of the system. Note: Testing of the plumbing system is not required to be witnessed by the Codes Administration Staff with the exception of gas piping.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

CA - 1999 NEC 250-104(b) - Metal gas piping. Each aboveground portion of a gas piping system upstream from the equipment shutoff valve shall be electrically continuous and bonded to the grounding electrode system.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $1,490.00 $1,490.00 Paid 12/30/2002
24 BLDG Plan Check Fees $44.80 $44.80 Paid 12/30/2002
25 Electrical Permit Fee $195.00 $195.00 Paid 12/30/2002
25 Mechanical Permit Fees $114.00 $114.00 Paid 12/30/2002
25 Plumbing Permit Fees $61.00 $61.00 Paid 12/30/2002
84 Water Meters $125.00 $125.00 Paid 12/30/2002
85 Water Taps $2,734.00 $2,734.00 Paid 12/30/2002
89 Sewer Tap Fees $270.00 $270.00 Paid 12/30/2002
Right of Way Permit $35.00 $35.00 Paid 12/30/2002
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 01/30/2003
Correction
Partial Correction
01/30/2003
None WEST LINE FROM SW CORNER NORTH LINE EAST LINE SOUTH 70` APPROX
Footing Inspection - Commercial Passed 01/31/2003
Correction
Resolved
01/31/2003
None
Underslab Plumbing Inspection - Commercial Not Ready 02/11/2003
Correction
Corrective Action Required
02/11/2003
READINESS FOR INSPECTION MAINTAIN ON-SITE FOR USE BY INSPECTORS FOR ALL INSPECTIONS THROUGH FINAL INSPECTION. NOT READY: PERMIT PRINTS NOT FOUND ON SITE
Erosion Control Inspection Residential Failed 02/11/2003
Correction
Corrective Action Required
02/11/2003
Erosion Control PER LSMO ORDINANCE NO. 3719 AND L.S. DESIGN & CONSTRUCTION MANUAL SILT FENCE PARTLY BURIED MAINTAIN EROSION CONTROL
Underslab Plumbing Inspection - Commercial Passed 02/12/2003
Correction
Resolved
02/12/2003
READINESS FOR INSPECTION
Correction
Resolved
02/12/2003
UNDERSLAB DWV PIPING APPROVED ESSENTIALLY AS DRWG P-1
Underslab Electrical Inspection - Commercial Passed 02/12/2003
Correction
Resolved
02/12/2003
PVC UNDERSLAB ELECT CONDUIT APPROVED OK TO COVER WHEN READY
Erosion Control Inspection Residential Passed 02/12/2003
Correction
Resolved
02/12/2003
Erosion Control
Erosion Control Inspection Residential Failed 03/13/2003
Correction
Corrective Action Required
03/13/2003
Erosion Control PER LSMO ORDINANCE NO. 3719: CLEAN WATERWAYS. INSTALL SILT FENCE, STRAW BALES, CRUSHED STONE, OR OTHER APPROVED EROSION CONTROL. TWO BUSINESS DAYS TO COMPLY BEFORE STOP CONSTRUCTION ORDER. ***NO OTHER INSPECTIONS UNTIL EROSION CONTROL IS APPROVED.*** LACK OF EROSION CONTROL EAST & NORTH BOUNDARIES
Erosion Control Inspection Residential Partial 03/18/2003
Correction
Partial Correction
03/18/2003
Erosion Control THANK YOU FOR PROVIDING EROSION CONTROL AT EAST PROPERTY LINE. AT NORTH P/L PLEASE DO SIMILARLY, AND CLEAR CONST MATERIAL (PIPE, ETC) FROM WATERWAY. LACK OF EROSION CONTROL NORTH BOUNDARY
Erosion Control Inspection Residential Passed 03/26/2003
Correction
Resolved
03/26/2003
Erosion Control
All Rough Inspection - Commercial Not Ready 03/26/2003
Correction
Corrective Action Required
03/26/2003
READINESS FOR INSPECTION DESIGN DRAWINGS NOT FOUND ON SITE. IRC R106.1; R502.1.4; R502.11: COMPLETE STRUCTURAL SYSTEM SUBJECT TO APPROVAL. FRAMING INSP REQUESTED MANUFACTURED JOIST SYSTEM
Rough Framing Inspection - Commercial Not Ready 03/27/2003
Correction
Corrective Action Required
03/27/2003
READINESS FOR INSPECTION NOT FOUND ON SITE MANUFACTURED TRUSS SYSTEM DESIGN DRAWINGS
Erosion Control Inspection Residential Passed 04/01/2003
All Rough Inspection - Commercial Partial 04/01/2003
Correction
Resolved
04/01/2003
READINESS FOR INSPECTION
Correction
Partial Correction
04/01/2003
EXTERIOR WALL & ROOF FRAMING APPROVED
Erosion Control Inspection Residential Partial 05/06/2003
Correction
Partial Correction
05/06/2003
Erosion Control ENSURE THEY ARE EFFECTIVE CONTINUALY AND PRIOR TO NEXT INSPECTION REQUEST. CHECK/MAINTAIN EROSION CONTROL MEASURES
All Rough Inspection - Commercial Partial 05/06/2003
Correction
Resolved
05/06/2003
EXTERIOR WALL & ROOF FRAMING
Correction
Partial Correction
05/06/2003
IN-WALL SYSTEMS AT LOCATIONS DISCUSSED DURING INSPECTION. OK TO COVER WALLS WHEN READY. CALL FOR ABOVE-CEILING INSPECTION WHEN READY. APPROVED CONTINGENT ON ADDITIONAL SHIELD PLATES
Erosion Control Inspection Residential Partial 05/08/2003
Footing Inspection - Commercial Passed 05/08/2003
Correction
Resolved
05/08/2003
ENTRY COLUMN PIERS APPROVED OK TO POUR WHEN READY
Sewer Service Inspection Passed 05/21/2003
Correction
Resolved
05/21/2003
APPROVED PER HSD DRWG SHEET 4/4
Water Service Inspection Passed 05/21/2003
Correction
Resolved
05/21/2003
APPROVED TAP IN PROGRESS BY LSWU BLDG ENTRY @ S E/O BLDG NOT PER HSD DRWG 4/4
Erosion Control Inspection Residential Failed 06/06/2003
Correction
Corrective Action Required
06/06/2003
Erosion Control
Correction
Corrective Action Required
06/06/2003
PROTECTION OF EAST DRAINAGE DITCH 1) CLEAR, CLEAN, GRADE TO DRAIN TO NORTH 2) REPAIR DAMAGE TO NEIGHBORING PROPERTY, INCLUDING REPLACE TREE 3) INSTALL / RESTORE TEMPORARY EROSION CONTROL ALONG W BANK ***TWO BUSINESS DAYS TO COMPLY. NO OTHER INSPECTIONS UNTIL EROSION CONTROL APPROVED*** EAST PROPERTY LINE REQUIRES IMMEDIATE WORK
Correction
Corrective Action Required
06/06/2003
PROTECTION OF NORTH DRAINAGE DITCH 1) CLEAR, CLEAN, TO DRAIN TO EAST 2) INSTALL / RESTORE TEMPORARY EROSION CONTROL ALONG S BANK ***TWO BUSINESS DAYS TO COMPLY. NO OTHER INSPECTIONS UNTIL EROSION CONTROL APPROVED*** N PROPERTY LINE REQUIRES IMMEDIATE WORK
Erosion Control Inspection Residential Failed 06/10/2003
Correction
Partial Correction
06/10/2003
Erosion Control
Correction
Corrective Action Required
06/10/2003
PROTECTION OF EAST DRAINAGE DITCH EAST PROPERTY LINE CLEAN, GRADE TO DRAIN
Correction
Corrective Action Required
06/10/2003
PROTECTION OF NORTH DRAINAGE DITCH N PROPERTY LINE CLEAR, CLEAN, TO DRAIN
Erosion Control Inspection Residential Failed 07/03/2003
Correction
Corrective Action Required
07/03/2003
Erosion Control
Correction
Corrective Action Required
07/03/2003
PROTECTION OF EAST DRAINAGE DITCH GRADE TO DRAIN. ***NO OTHER INSPECTIONS UNTIL EROSION CONTROL APPROVED*** EAST PROPERTY LINE CLEAR; REMOVE ALL DEBRIS
Correction
Corrective Action Required
07/03/2003
PROTECTION OF NORTH DRAINAGE DITCH ***NO OTHER INSPECTIONS UNTIL EROSION CONTROL APPROVED*** N PROPERTY LINE CLEAR OF ALL DIRT &DEBRIS
Electrical Service Inspection Not Ready 07/03/2003
Correction
Corrective Action Required
07/03/2003
READINESS FOR INSPECTION LSCO 7-142: NOT READY FOR INSPECTION PERMIT PRINTS NOT FOUND ON SITE
Above Ceiling Inspection Failed 07/03/2003
Correction
Corrective Action Required
07/03/2003
SYSTEMS BEING COVERED IN PROGRESS. NO ABOVE-CEILING INSPECTION HAS BEEN REQUESTED OR PERFORMED. WITHOUT APPROVAL CEILING TILE INSTALLATION
Electrical Service Inspection Passed 07/08/2003
Correction
Resolved
07/08/2003
READINESS FOR INSPECTION
Correction
Resolved
07/08/2003
NONE > APPROVED RELEASE SERVICE
Above Ceiling Inspection Failed 07/08/2003
Correction
Corrective Action Required
07/08/2003
SYSTEMS BEING COVERED AT S END OF CENTRAL CORRIDOR PRIOR TO ABOVE-CEILING INSPECTION WITHOUT APPROVAL CEILING TILE INSTALLED
Correction
Corrective Action Required
07/08/2003
SECURING/SUPPORT OF NM ELECTRICAL CABLE NEC 336-18; IRC E3702.1: LAID LOOSE OVER TAIL OF CEILING SUPPORT HANGER TAIL DOES NOT CONSTITUTE SUPPORT. 4.5' MAX INTERVALS AND WITHIN 8" OF BOXES
Correction
Corrective Action Required
07/08/2003
SUPPORT/SECURING OF TEMPERATURE CONTROL CABLE WHEREVER POSSIBLE. LAID LOOSE OVER TAIL OF CEILING SUPPORT HANGER TAIL DOES NOT CONSTITUTE SUPPORT. SUPPORT/SECURE ABOVE CEILING & MEP SYSYEMS
Above Ceiling Inspection Passed 07/09/2003
Correction
Resolved
07/09/2003
SYSTEMS BEING COVERED OK TO COVER WHEN READY
Correction
Resolved
07/09/2003
SECURING/SUPPORT OF NM ELECTRICAL CABLE CORRECTION IN PROGRESS
Correction
Resolved
07/09/2003
SUPPORT/SECURING OF TEMPERATURE CONTROL CABLE CORRECTIONS IN PROGRESS
Piers/Caissons Inspection - Commercial Passed 07/11/2003
Correction
Resolved
07/11/2003
CONCRETE LIGHT POLE BASES 24" BASES FOR HIGH POLES NOT SHOWN ON DRAWINGS; THEREFORE OBSERVED BUT NOT APPROVED. HOLES DUG 5'+- DEEP; FOUR #4 VERTICAL RE-BAR 12" BOLLARDS OK PER DRWG
Occupancy Inspection - Codes Commercial Failed 07/28/2003
Correction
Corrective Action Required
07/28/2003
Receive Planning & Development Approval
Correction
Corrective Action Required
07/28/2003
Receive Public Works Approval
Correction
Corrective Action Required
07/28/2003
Receive Water Utilities Approval
Correction
Corrective Action Required
07/28/2003
PVC ELECTRICAL CONDUIT @ LIGHT POLE BAES EXPOSED ABOVE GRADE SUBJECT TO DAMAGE
Correction
Corrective Action Required
07/28/2003
PERIMETER OF STONE VENEER WALL PANELS NOT SEALED
Correction
Corrective Action Required
07/28/2003
PENETRATIONS BEHIND HVAC DISCONNECTS OF ALL CABINETS TO WALL NOT SEALED SEAL PERIMETERS
Correction
Corrective Action Required
07/28/2003
PAINTING EXTERIOR OF REAR DOORS NOT ACCOMPLISHED
Correction
Corrective Action Required
07/28/2003
ELECTRICAL RECEPTACLES/SWITCHES NEC 380-10; 410-56(f): VARIOUS LOCATIONS; CHECKALL NOT TIGHT TO BOX BUILDING INTERIOR
Correction
Corrective Action Required
07/28/2003
EMERGENCY LIGHT @ OFFICE 109 NOT OPERATING
Correction
Corrective Action Required
07/28/2003
EXIT SIGN @ REAR DOOR NEXT TO FURNACE 115 NOT INSTALLED
Correction
Corrective Action Required
07/28/2003
LABELING OF ELECTRICAL CIRCUIT BREAKERS IRC E36O6.2. LABEL PANELS + EACH BREAKER MUST BE LABELED. MUST BE LEGIBLE; SPECIFIC. INCOMPLETE/IMPROPER SERVICE PANEL
Correction
Corrective Action Required
07/28/2003
OCCUPANCY STATUS IBC 110.1 / IRC R110: UNTIL APPROVED DO NOT OCCUPY OR PLACE PERSONAL PROPERTY
All Rough Inspection - Commercial Passed 07/31/2003
Correction
Resolved
07/31/2003
IN-WALL SYSTEMS
Occupancy Inspection - Codes Commercial Failed 07/31/2003
Correction
Corrective Action Required
07/31/2003
Receive Planning & Development Approval CONTACT TOM SCANNELL 969-7796
Correction
Corrective Action Required
07/31/2003
Receive Public Works Approval CONTACT MIKE WEISENBORN 969-7450
Correction
Resolved
07/31/2003
Receive Water Utilities Approval PER J WALTERS 7/29/03 E-MAIL
Correction
Resolved
07/31/2003
PVC ELECTRICAL CONDUIT @ LIGHT POLE BAES
Correction
Partial Correction
07/31/2003
PERIMETER OF STONE VENEER WALL PANELS SEALING OF JOINT IN-PROGRESS
Correction
Resolved
07/31/2003
PENETRATIONS BEHIND HVAC DISCONNECTS
Correction
Resolved
07/31/2003
PAINTING EXTERIOR OF REAR DOORS
Correction
Corrective Action Required
07/31/2003
ELECTRICAL RECEPTACLES/SWITCHES NEC 380-10; 410-56(f): VARIOUS LOCATIONS; CHECK ALL NOT TIGHT TO BOX BUILDING INTERIOR
Correction
Resolved
07/31/2003
EMERGENCY LIGHT @ OFFICE 109
Correction
Resolved
07/31/2003
EXIT SIGN @ REAR DOOR NEXT TO FURNACE 115
Correction
Resolved
07/31/2003
LABELING OF ELECTRICAL CIRCUIT BREAKERS
Correction
Corrective Action Required
07/31/2003
OCCUPANCY STATUS IBC 110.1: UNTIL ELECTRICAL RECEPTACLES ARE APPROVED DO NOT OCCUPY OR PLACE PERSONAL PROPERTY
Correction
Corrective Action Required
07/31/2003
CONCRETE FLOW CHANNEL @ NORTH PROP LINE DIRT LEFT IN CHANNEL FROM LANDSCAPING ACTIVITY
Rough Framing Inspection - Commercial Passed 07/31/2003
Correction
Resolved
07/31/2003
READINESS FOR INSPECTION
Erosion Control Inspection Residential Passed 07/31/2003
Correction
Resolved
07/31/2003
Erosion Control
Correction
Resolved
07/31/2003
PROTECTION OF EAST DRAINAGE DITCH
Correction
Resolved
07/31/2003
PROTECTION OF NORTH DRAINAGE DITCH
Occupancy Inspection - Codes Commercial Failed 08/01/2003
Correction
Resolved
08/01/2003
ELECTRICAL RECEPTACLES/SWITCHES
Correction
Partial Correction
08/01/2003
OCCUPANCY STATUS SEE TEMPORARY OCCUPANCY
Correction
Resolved
08/01/2003
CONCRETE FLOW CHANNEL @ NORTH PROP LINE
Occupancy Inspection - Codes Commercial Failed 08/13/2003
Correction
Resolved
08/13/2003
Receive Public Works Approval PER MIKE WEISENBORN
Occupancy Inspection - Codes Commercial Failed 08/13/2003
Correction
Resolved
08/13/2003
Receive Planning & Development Approval PER TOM SCANNELL 8/13/03
Occupancy Inspection - Codes Commercial Passed 08/18/2003
Correction
Resolved
08/18/2003
PERIMETER OF STONE VENEER WALL PANELS RECOMMEND ADDITIONAL SEALANT BE PLACED
Correction
Resolved
08/18/2003
OCCUPANCY STATUS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home