Permit Application Status

B0201891


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0201891
Building Permit - Commercial
Certificate of Occupancy
OCTOBER SKY DEVELOPERS LLC
NEW COMMERCIAL
OFFICE/WAREHOUSE BUILDING
10/24/2002
12/03/2002
06/01/2003
02/02/2004
Locations
Contacts
CHAPMAN ARCHITECTS, Address:2412 W 71ST STREET  
HEARTLAND STUCCO, Address:5112 SW PIPING PLOVER DR  
OCTOBER SKY DEVELOPERS LLC, Address:PO BOX 2372  
CFC SQUARED LLC, Address:1314 SW MARKET ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 04/22/2003 10/29/2010
Correction

Fire Department- Depending on use of the building additional fire protection and permits may be required for the space. Approval of the submitted plan does not waive any additional requirements. Use of the building is subject to field verification.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

CA - The pre-engineered metal building plans were not submitted with the building permit application.
Correction

CA - Details are not provided on the framing of the interior walls or the exterior walls and roof of the office area.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - 2000 IBC 1003.3.1.4 - Floor Elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal.
Correction

CA - 2000 IBC 1003.3.1.5 - Landings at doors. Landings shall have a width not less than the width of the stairway or the width of the door, whichever is the greater. Doors in the fully open position shall not reduce a required dimension by more than 7 inches. When a landing serves an occupant load of 50 or more, doors in any position shall not reduce the landing to less than one-half its required width. Landings shall have a length measured in the direction of travel of not less than 44 inches.
Correction

CA - 2000 IBC 1003.3.1.6 - Thresholds. Thresholds at doorways shall not exceed 0.75 inch in height for sliding doors serving dwelling units or 0.5 inch for other doors. Raised thresholds and floor level changes greater then 0.25 inch at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope).
Correction

CA - 2000 IBC 1404.2 - Water-resistive barrier. A minimum of one layer of No. 15 asphalt felt, complying with ASTM D 226 for Type 1 felt, shall be attached to the sheathing, with flashing as described in Section 1405.3, in such a manner as to provide a continous water-resistive barrier behind the exterior wall veneer.
Correction

CA - 2000 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as devined in Section 2406.2 shall pass the test requirements of CPSC 16 CFR 1201, listed in Chapter 35. Glazing shall comply with the CSPC 16 CFR, Part 1201 criteria for Category I or Category II as indicated in Table 2406.1.
Correction

CA - 2000 IBC 1104.1 - Site arrival points. Accessible routes within the site shall be provided from public transportation stops, accessible parking and accessible passenger loading zones, and public streets or sidewalks to the accessible building entrance served.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

CA - 2000 IMC 403.3 - Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with Table 403.3 based on the occupancy of the space and the occupant load or other perameter as stated therein. The occupant load utilized for design of the ventilation system shall not be less then the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code.
Correction

CA - 2000 IMC 304.8 - Clearances from grade. Equipment and appliances installed at grade level shall be supported on a level concrete slab or other approved material extending above adjoining grade or shall be suspended a minimum of 6 inches (152 mm) aboave adjoining grade.
Correction

CA - 2000 IPC 504.3 - A means of disconnecting an electric hot water supply system from its energy supply shall be provided in accordance with the 1999 National Electric Code. A seperate valve shall be provided to shut off the energy fuel supply to all other types of hot water supply systems.
Correction

CA - 2000 IPC 308.5 - Pipe shall be supported in accordance with Table 308.5.
Correction

CA - 2000 IPC 312.1 - Required tests. The permit holder shall make the applicable test prescribed in Sections 312.2 through 312.9 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. All plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain if the pressure has reached all parts of the system. Note: Testing of the plumbing system is not required to be witnessed by the Codes Administration Staff with the exception of gas piping.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - LSCO Chapter 7, Section 7-803 - Non-residential occupancies. The minimum required R-value for each element of the building thermal envelope shall be in accordance with the following; Exception: The Building Official may approve a decreased R-value for building exterior walls provided the space is not occupied by employees and is associated with storage/warehouse or manufactoring. a) Wall assemblies forming portions of a building envelope shall meet or exceed an R factor rating of 11. This requirement does not apply to doors, windows or openings or approved penetrations nor does it apply to unfinished basement concrete walls. b) Floor assemblies forming portions of a building envelope shall meet or exceed a R factor rating of 19. Exception: Concrete floor in contact with the earth need not be insulated. c) Roof assemblies forming portions of a building envelope shall meet or exceed an R factor of 19.
Correction

CA - 1999 NEC 250-104(a) - Metal water piping. The interior metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. The bonding jumper shall be installed in accordance with Section 250-64(a), (b), and (e). The points of attachment of the bonding jumper(s) shall be accessible.
Correction

CA - 1999 NEC 250-104(b) - Metal gas piping. Each aboveground portion of a gas piping system upstream from the equipment shutoff valve shall be electrically continuous and bonded to the grounding electrode system.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All backflow prevention assemblies must be tested and reports filed with the Lee's Summit Water Utilities Backflow Division (816-969-7636) within 30 days from the date installed.
Correction

Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $722.00 $722.00 Paid 12/03/2002
24 BLDG Plan Check Fees $32.00 $32.00 Paid 12/03/2002
25 Electrical Permit Fee $112.00 $112.00 Paid 12/03/2002
25 Mechanical Permit Fees $76.00 $76.00 Paid 12/03/2002
25 Plumbing Permit Fees $69.00 $69.00 Paid 12/03/2002
84 Water Meters $125.00 $125.00 Paid 12/03/2002
85 Water Taps $2,734.00 $2,734.00 Paid 12/03/2002
89 Sewer Tap Fees $300.00 $300.00 Paid 12/03/2002
Right of Way Permit $35.00 $35.00 Paid 12/03/2002
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection Partial 12/06/2002
Correction
Partial Correction
12/06/2002
None TO METER SITE
Sewer Service Inspection Partial 12/06/2002
Correction
Partial Correction
12/06/2002
None TO GRINDER PUMP
Water Service Inspection Passed 12/09/2002
Correction
Resolved
12/09/2002
None
Sewer Service Inspection Passed 12/09/2002
Correction
Resolved
12/09/2002
None
All Rough Inspection - Commercial Failed 02/06/2003
Correction
Corrective Action Required
02/06/2003
Rough electrical incomplete.
Correction
Corrective Action Required
02/06/2003
Rough plumbing not started.
Rough Framing Inspection - Commercial Passed 02/06/2003
All Rough Inspection - Commercial Failed 02/25/2003
Correction
Partial Correction
02/25/2003
Rough electrical incomplete. WALLS OK. FINISH ABOVE CEILING. OKAY TO INSULATE, OKAY TO ROCK
Correction
Resolved
02/25/2003
Rough plumbing not started.
Electrical Service Inspection Passed 02/25/2003
Gas Piping Inspection - Commercial Passed 02/27/2003
Gas Service Inspection - Commercial Passed 02/27/2003
Above Ceiling Inspection Passed 05/12/2003
Correction
Resolved
05/12/2003
None OFFICE AREA ABOVE CEILING APPROVED. OKAY TO DROP TILE WHEN READY.
All Rough Inspection - Commercial Passed 06/24/2003
Correction
Resolved
06/24/2003
Rough electrical incomplete.
Occupancy Inspection - Codes Commercial Failed 06/24/2003
Correction
Corrective Action Required
06/24/2003
Receive Planning & Development Approval COMPLETE LANDSCAPING, CUT OFF SHIELDS REQUIRED AT WEST EXTERIOR LIGHTS, INSTALL TRASH ENCLOSURE GATE, SCREEN A.C. UNITS.
Correction
Corrective Action Required
06/24/2003
Receive Water Utilities Approval SUBMIT BACKFLOW TEST REPORTS FOR DOMESTIC SERVICE AND IRRIGATION SYSTEM.
Correction
Resolved
06/24/2003
None
Correction
Corrective Action Required
06/24/2003
IRRIGATION PERMIT OBTAIN IRRIGATION PERMIT
Occupancy Inspection - Codes Commercial Failed 07/23/2003
Correction
Resolved
07/23/2003
IRRIGATION PERMIT
Occupancy Inspection - Codes Commercial Failed 09/11/2003
Correction
Corrective Action Required
09/11/2003
Grab Bar in Bathroom Grab bar required in bathroom.
Occupancy Inspection - Codes Commercial Failed 12/22/2003
Correction
Corrective Action Required
12/22/2003
Receive Planning & Development Approval PROVIDE MECH UNIT LANDSCAPE SCREEN @ REAR PROVIDE ADDITIONAL LANDSCAPING AT REAR PROVIDE STELL TRASH GATE ENCLOSURE
Correction
Corrective Action Required
12/22/2003
Receive Water Utilities Approval SUBMIT BACKFLOW TEST REPORTS FOR DOMESTIC SERVICE AND IRRIGATION SYSTEM.
Correction
Resolved
12/22/2003
Grab Bar in Bathroom
Occupancy Inspection - Codes Commercial Failed 12/23/2003
Correction
Resolved
12/23/2003
Receive Water Utilities Approval
Occupancy Inspection - Codes Commercial Passed 01/30/2004
Correction
Resolved
01/30/2004
Receive Planning & Development Approval
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home