Permit Application Status

B0201167


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0201167
Building Permit - Commercial
Certificate of Occupancy
VILLE 36 INVESTMENT COMPANY LLC
NEW TENANT FINISH
TENANT FINISH
07/11/2002
08/21/2002
02/17/2003
12/09/2002
Locations
Contacts
PACE COMMERCIAL BUILDERS, Address:11490 STRANG LINE RD  
VILLE 36 INVESTMENT COMPANY LLC, Address:4740 ROANOKE PKWY  
SUMMIT WOODS SPE LLC, Address:1 E WASHINGTON ST STE 300  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/07/2003 10/29/2010
Correction

CA - There is a discrepancy between the construction type listed in the Code Review Information and the Code Reference Plan on sheet ACVR. The correct construction type for this building is type II-B.
Correction

CA - There is a discrepancy between the occupant load listed in "occupant load" and "exit width" in the Code Review Information section of sheet ACVR.
Correction

CA - Interior wall and ceiling finishes shall be at least Class C in accordance with ASTM E 84 per IBC table 803.4.
Correction

CA - Accesible signage is required per IBC section 1109.
Correction

CA - On sheet A201, it appears that the FRP on the bathroom walls extends to a height of 3'-4". Per IBC 1209.2, the minimum required height of the hard, non-absorbent surface adjacent to a water closet is 4' above the floor.
Correction

Fire Department: the existing fire sprinkler system shall provide coverage for the occupancy.
Correction

Fire Department:included in the system shall be an isolation valve on the sprinkler system to the space. Also needed is a flow alarm on the sprinkler system to activate upon water release equal to or greater than a single sprinkler head.
Correction

Fire Department: the sprinkler system shall be monitored with the alarm tied into the central alarm panel existing for the building. The occupant may install a seperate water flow alarm monitoring system if desired but both the existing system and the new system must be able to communicate.
Correction

Fire Department: the inspectors test and drain may tie into the main drain located in the corridor of the existing building or drain to the exterior.
Correction

Fire Department: Occupant space shall be provided throughout with horn/strobe occupant notification to activate upon water flow from the sprinkler system.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Fire Department; IFC 1003.3.1.8 Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Fire Department; Egress from a room or space shall not pass through adjoining or interven-ing rooms or areas, except where such adjoining rooms or areas are accessory to the area served; are not a high-hazard occupancy; and provide a discernible path of egress travel to an exit. Egress shall not pass through kitchens, store rooms, closets or spaces used for similar purposes. An exit access shall not pass though a room which can be locked to prevent egress. IFC 1004.2.3
Correction

Fire Department; Required means of egress components shall be maintained during construction and demolition.
Correction

Fire Department; Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. Combustible debris, waste materials and trash shall not be burned on site.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. The plans and specifications shall bear a State of Missouri licensed engineers seal. This includes fire sprinkler systems, grease hood and duct suppression systems as well as other fire suppression system.
Correction

Fire Department: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue pro-tection whenever the building is altered, remodeled or added to.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-7343.
Correction

Fire Department: Fire detection, alarm and extinguishing systems shall be maintained in an op-erative condition at all times, and shall be replaced or repaired where defective.
Correction

Fire Department; All valves controlling the water supply for automatic sprinkler systems and water-flow switches on all sprinkler systems shall be electrically supervised when the number of sprinkler heads are 20 (twenty) or greater.
Correction

Fire Department; Valve supervision and water flow alarm and trouble signals shall be distinctly different and shall be automatically transmitted to an approved central station, remote supervising station or proprietary supervising station as defined in NFPA72 or, when approved by the code official, shall sound an audible signal at a constantly attended location.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $146.00 $146.00 Paid 08/21/2002
24 BLDG Plan Check Fees $14.00 $14.00 Paid 08/21/2002
25 Electrical Permit Fee $60.00 $60.00 Paid 08/21/2002
25 Mechanical Permit Fees $56.00 $56.00 Paid 08/21/2002
25 Plumbing Permit Fees $23.00 $23.00 Paid 08/21/2002
89 Sewer Tap Fees $120.00 $120.00 Paid 08/21/2002
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underground Plumbing Inspection - Commercial Passed 08/22/2002
Rough Electrical Inspection - Commercial Passed 08/27/2002
Correction
Resolved
08/27/2002
None WALLS ONLY - APPROVED
Rough Framing Inspection - Commercial Failed 08/27/2002
Correction
Corrective Action Required
08/27/2002
BLOCKING ALL WOOD BLOCKING IS REQUIREDTO BE FIRE TREATED WOOD PER PLANS METAL STUD FRAMING APPROVED FINISHED WALL TO BE COMPLETED PER UL DESIGN IN PLANS
Electrical Service Inspection Passed 08/28/2002
Rough Framing Inspection - Commercial Passed 08/28/2002
Correction
Resolved
08/28/2002
BLOCKING
Rough Plumbing Inspection - Commercial Partial 08/28/2002
Correction
Partial Correction
08/28/2002
None IN WALL ONLY
Miscellaneous Inspection Passed 08/28/2002
Correction
Resolved
08/28/2002
NOT READY
Occupancy Inspection - Codes Commercial Failed 09/06/2002
Correction
Corrective Action Required
09/06/2002
Receive Fire Department approval DUCT DETECTOR ISSUES
Correction
Corrective Action Required
09/06/2002
TYPE YOUR OWN TEXT COMPLETE WATER HEATER INSTALL PIPE T/P DISCHARGE EXPANSION CONTROL
Occupancy Inspection - Codes Commercial Failed 10/03/2002
Correction
Corrective Action Required
10/03/2002
TYPE YOUR OWN TEXT SUPPORT REVENT
Occupancy Inspection - Codes Commercial Passed 12/04/2002
Correction
Resolved
12/04/2002
Receive Fire Department approval fd approval per Jim Eden
Correction
Resolved
12/04/2002
TYPE YOUR OWN TEXT SUPPORT REVENT
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home