Permit Application Status

B0200625


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0200625
Building Permit - Commercial
Certificate of Occupancy
TLS MARKET PLACE LLC
NEW COMMERCIAL
NEW BUILDING
04/18/2002
08/05/2002
02/01/2003
08/01/2005
Locations
Contacts
CUMBERLAND PROPERTIES INC., Address:317 SW MARKET  
TLS MARKET PLACE LLC, Address:P O BOX 3994  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 10/15/2002 10/29/2010
Correction

P & D - No comments can be provided. Final development plan not been submitted. The ordinance for the preliminary development plan is scheduled for 5-02-02. A final development plan application shall be submitted and approved prior to the issuance of a building permit.
Correction

CA - Provide the listing number for the floor ceiling assembly between the B and A-2 occupancies.
Correction

CA - The guard rail and handrail located on the stairs from the upper floor must meet the requirements of the Internationl Building Code. The stairs must have a guard rail a minimum of 42" tall and a handrail 34" to 38" above the nosing of the stair treads.
Correction

CA - Clarify the rise and run of the stairs. The stair run must be a minimum of 11" and the rise a maximum of 7". Two sheets have conflicting information.
Correction

CA - The handicap ramp located in the parking lot must meet the requirements of ANSI A 117.1.
Correction

CA - Submit a spec sheet for the epoxy paint to be used in the restrooms.
Correction

CA - An electrical outlet must be with 25' of all mechical equipment. The roof equipment must also have an outlet within 25'.
Correction

CA - All piping must be properly supported per the 2000 International Plumbing Code.
Correction

CA - all plumbing, gas and water lines must be tested and approved per the 2000 International Plumbing Code.
Correction

CA - All plumbing fixtures must have sut-off valves installed per the 2000 International Plumbing Code.
Correction

Fire Department; Smoke detectors shall be provided per IFC Sec. 907.2.10.1.2 in the R-occupancies.
Correction

P & D - Sign permits must be obtained for all signs prior to installation through the Department of Planning and Development. All signs shall comply with the sign requirements outlined in the UDO, Article 13. ISSUANCE OF A BUILDING PERMIT DOES NOT CONSTITUTE APPROVAL OR REVIEW OF ANY SIGNS INDICATED ON BUILDING ELEVATIONS OR SITE PLAN.
Correction

P & D - Rooftop mechanical units are shown to be screened by the parapet and roof screens. If the rooftop mechanical units are visible, the Certificate of Occupancy will be held until the rooftop mechanical units are entirely screened from view in accordance with the UDO requirements.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

Fire Department; IFC 1003.3.1.8 Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

1003.2.10.1 Fire Department- Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30 480 mm) from the nearest visible exit sign.
Correction

Fire Department; Egress from a room or space shall not pass through adjoining or interven-ing rooms or areas, except where such adjoining rooms or areas are accessory to the area served; are not a high-hazard occupancy; and provide a discernible path of egress travel to an exit. Egress shall not pass through kitchens, store rooms, closets or spaces used for similar purposes. An exit access shall not pass though a room which can be locked to prevent egress. IFC 1004.2.3
Correction

Fire Department; Required means of egress components shall be maintained during construction and demolition.
Correction

Fire Department; Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. Combustible debris, waste materials and trash shall not be burned on site.
Correction

Fire Department; Dumpsters and containers with an individual capacity of 1.5 cubic yards (40.5 cubic feet) or more shall not be stored in buildings or placed within 5 feet of combustible walls, openings or combustible roof eave lines.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $1,802.00 $1,802.00 Paid 08/05/2002
24 BLDG Plan Check Fees $50.00 $50.00 Paid 08/05/2002
25 Electrical Permit Fee $339.20 $339.20 Paid 08/05/2002
25 Mechanical Permit Fees $249.00 $249.00 Paid 08/05/2002
25 Plumbing Permit Fees $147.50 $147.50 Paid 08/05/2002
84 Water Meters $200.00 $200.00 Paid 08/05/2002
85 Water Taps $2,734.00 $2,734.00 Paid 08/05/2002
89 Sewer Tap Fees $930.00 $930.00 Paid 08/05/2002
Right of Way Permit $35.00 $35.00 Paid 08/05/2002
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Passed 08/06/2002
Underground Plumbing Inspection - Commercial Passed 08/21/2002
Sewer Service Inspection Partial 10/08/2002
Correction
Partial Correction
10/08/2002
NONE > PARTIAL SEWER SERVICE DUE TO REVISED TIE-IN LOCATION. CONTRARY TO DRWG C1, TIE-IN POINT WILL BE SOUTH OF BUILDING. 6" LINE PRESENTLY LAID FROM BUILDING ENTRY S/SW. 90 LF LAID AT THIS POINT. SEE SKETCH. APPROVED CONTINGENT ON PUBLIC WORKS
Sewer Service Inspection Passed 10/10/2002
Correction
Resolved
10/10/2002
NONE > PARTIAL SEWER SERVICE SUBMIT CHANGE OF DIRECTION OF LINE ON "AS BUILT" REPORT.
Water Service Inspection Passed 10/18/2002
Electrical Service Inspection Partial 11/13/2002
Correction
Partial Correction
11/13/2002
None 517 AND HOUSE 517A ONLY
All Rough Inspection - Commercial Partial 01/10/2003
Correction
Partial Correction
01/10/2003
None OK TO START BASE LAYER FLOOR/CEILING ASSY ENSURE LISTED ASSY TO HAVE THROUGH AND MEMBRANE PENETRATIONS PROTECTED OK TO COVER NON RATED ASSY
Rated Assembly Inspection Partial 01/16/2003
Correction
Partial Correction
01/16/2003
None SCREW PATTERN APPROVED PROTECT MATERIALS IN 1HR ASSY
Above Ceiling Inspection Passed 02/07/2003
Correction
Resolved
02/07/2003
ABOVE-CEILING SYSTEMS OK TO COVER WHEN READY GROUND FLOOR ROOMS APPROVED
Occupancy Inspection - Codes Commercial Failed 02/13/2003
Correction
Corrective Action Required
02/13/2003
FIRESTOP OCCUPANCY SEPARATION 521 FURNACE ROOM
Correction
Partial Correction
02/13/2003
ELECTRICAL RECEPTACLES/SWITCHES IRC E3901.10; E3902.6 <> NEC 380-10; 410-56(f) CHECK ALL. EXAMPLES CITED DURING INSPECTION. NOT TIGHT TO BOX VARIOUS LOCATIONS
Correction
Corrective Action Required
02/13/2003
Receive Fire Department approval
Correction
Corrective Action Required
02/13/2003
Receive Public Works Approval
Correction
Corrective Action Required
02/13/2003
Receive Planning & Development Approval COPY PROVIDED T SCANNELL E-MAIL MESSAGE DATED 2/13/03
Correction
Corrective Action Required
02/13/2003
SOD & SIDEWALK S END OF BUILDING
Correction
Corrective Action Required
02/13/2003
STRIPING OF PARKING LOT NOT DONE
Electrical Service Inspection Partial 12/03/2003
Rated Assembly Inspection Partial 12/03/2003
Correction
Partial Correction
12/03/2003
None SCREW PATTERN APPROVED PROTECT MATERIALS IN 1HR ASSY
All Rough Inspection - Commercial Partial 12/03/2003
Correction
Partial Correction
12/03/2003
None OK TO START BASE LAYER FLOOR/CEILING ASSY ENSURE LISTED ASSY TO HAVE THROUGH AND MEMBRANE PENETRATIONS PROTECTED OK TO COVER NON RATED ASSY
Occupancy Inspection - Codes Commercial Failed 12/03/2003
Correction
Corrective Action Required
12/03/2003
SOD & SIDEWALK S END OF BUILDING
Occupancy Inspection - Codes Commercial Failed 01/06/2004
All Rough Inspection - Commercial Partial 01/06/2004
Correction
Partial Correction
01/06/2004
None OK TO START BASE LAYER FLOOR/CEILING ASSY ENSURE LISTED ASSY TO HAVE THROUGH AND MEMBRANE PENETRATIONS PROTECTED OK TO COVER NON RATED ASSY
Rated Assembly Inspection Partial 01/06/2004
Correction
Partial Correction
01/06/2004
None SCREW PATTERN APPROVED PROTECT MATERIALS IN 1HR ASSY
Electrical Service Inspection Partial 01/06/2004
Correction
Partial Correction
01/06/2004
None 517 AND HOUSE 517A ONLY
Occupancy Inspection - Codes Commercial Failed 01/27/2004
All Rough Inspection - Commercial Partial 01/27/2004
Correction
Partial Correction
01/27/2004
None OK TO START BASE LAYER FLOOR/CEILING ASSY ENSURE LISTED ASSY TO HAVE THROUGH AND MEMBRANE PENETRATIONS PROTECTED OK TO COVER NON RATED ASSY
Rated Assembly Inspection Partial 01/27/2004
Correction
Partial Correction
01/27/2004
None SCREW PATTERN APPROVED PROTECT MATERIALS IN 1HR ASSY
Electrical Service Inspection Partial 01/27/2004
Correction
Partial Correction
01/27/2004
None 517 AND HOUSE 517A ONLY
Occupancy Inspection - Codes Commercial Failed 02/09/2004
Correction
Resolved
02/09/2004
Receive Public Works Approval PER M WEISENBORN 3/21/03
Correction
Resolved
02/09/2004
SOD & SIDEWALK
Correction
Corrective Action Required
02/09/2004
Receive Water Utilities Approval
Occupancy Inspection - Codes Commercial Failed 02/10/2004
Correction
Resolved
02/10/2004
ELECTRICAL RECEPTACLES/SWITCHES IRC E3901.10; E3902.6 <> NEC 380-10; 410-56(f) ENSURE ALL ARE MAINTAIND TIGHT TO BOX
Correction
Resolved
02/10/2004
Receive Fire Department approval PER J EDEN 2/9/04
Occupancy Inspection - Codes Commercial Failed 02/11/2004
Correction
Resolved
02/11/2004
Receive Water Utilities Approval PER J WALTERS 2/10/04
All Rough Inspection - Commercial Passed 02/11/2004
Correction
Resolved
02/11/2004
None
Rated Assembly Inspection Passed 02/11/2004
Correction
Resolved
02/11/2004
None
Occupancy Inspection - Codes Commercial Failed 03/04/2004
Correction
Resolved
03/04/2004
FIRESTOP OCCUPANCY SEPARATION
Correction
Resolved
03/04/2004
STRIPING OF PARKING LOT COMPLETED BUT SUBJECT TO APPROVAL BY P&D
Occupancy Inspection - Codes Commercial Passed 07/28/2005
Correction
Resolved
07/28/2005
ELECTRICAL RECEPTACLES/SWITCHES
Correction
Resolved
07/28/2005
Receive Planning & Development Approval NO REMAINING ISSUES KNOWN
Correction
Resolved
07/28/2005
STRIPING OF PARKING LOT
Electrical Service Inspection Passed 07/29/2005
Correction
Resolved
07/29/2005
None 517 AND HOUSE 517A ONLY
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home