Permit Application Status

B0100082


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0100082
Building Permit - Commercial
Final Completion
DEE JAYS QSR OF KANSAS INC
ALTERATION COMMERCIAL
INTERIOR REMODEL
01/22/2001
02/22/2001
08/21/2001
04/04/2001
Locations
Contacts
DJUAN JACKSON ARCVISION INC, Address:10810 INDIAN HEAD IND. BLVD  
DEE JAYS QSR OF KANSAS INC, Address:110 PERKINS RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/21/2001 10/29/2010
Correction

Codes Administration- No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

Codes Administration- Each structure shall have the address of that structure visibly posted on the jobsite throughout the construction process.
Correction

Codes Administration- A completed License Tax application must be submitted to the City of Lee's Summit and any applicable License Tax paid prior to issuing a building permit.
Correction

Codes Administration - It shall be unlawful for any person to engage in any business or manufacturing within the City without first having obtained a license therefor, paying the license fee, and registering the business or manufacturer with the Director of Finance or the Director's representative. (Lee's Summit Code of Ordinances, Section 28-24.) It is the general contractors responsiblity to make sure that all the trades on their project are licensed with the City of Lee's Summit.
Correction

Codes Administration- It shall be the duty of the person doing the work authorized by a permit to notifiy the Building Inspections Division that such work is ready for inspection. (UBC Section 305.(c))
Correction

Codes Administration- Exit doors shall be openable from the inside without the use of a key or special knowledge. (UBC Section 3304.(c))
Correction

Codes Administration- When two or more exits from a story are required by Section 3303, exit signs shall be installed at stair enclosure doors, horizontal exits and other required exits from the story. When two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicate the direction of egress. 1991 Uniform Building Code Section3314.(a)
Correction

Codes Administration- In public areas of Group B, Division 2 Occupancies, and in assembly occupancies without fixed seats, the minimum clear aisle width shall be 36 inches where tables, counters, furnishings, merchandise or other similar obstructions are placed on one side of the aisle only and 44 inches when such obstructions are placed on both sides of the aisle. 1991 UBC Section 3315.b.2
Correction

Codes Administration- Exit doors from a Group A Occupancies having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. (1991 Uniform Building Code, Section 3317.(d).)
Correction

P & D - The plan submitted January 22, 2001 proposes T-1-11 panels on the exterior of the restaurant. T-1-11 is not on the approved materials list or the conditional materials list. Under Ord. 715, Sec. 260. B.a.3. plywood paneling is prohibited. In addition, exterior wall materials which are not otherwise listed above as "approved" or "conditional" are expressly prohibited.
Correction

P & D - Since there is already an existing detached sign on the site, the new "billboard style" roof sign proposed on the front facade is not permissable. The ordinance specifically states, "In lieu of one detached sign, one (1) unilluminated, semi-illuminated or indirectly illuminated roof sign shall be permitted." See Ord. 715, Sec. 350. C. 5.d.
Correction

P & D - It is determined that the DRIVE THRU sign proposed on the left side (north) elevation (Sheet A3) is an "incidental sign." It appears to be larger than the minimum allowed for an incidental sign.
Correction

P & D - Provide a color schedule of all the exterior materials proposed or submit a "color rendering" of the restaurant.
Correction

WU - A grease/solids interceptor must be shown with an indication of size, type and detail of the interceptor.
Correction

WU - The existing backflow prevention assembly must be shown on plumbing plans.
Correction

WU - Backflow prevention assembly will be placed inside the building on the domestic water service line prior to any point of use.
Correction

WU - Backflow prevention assembly must be located in an accessible location, min. 12" from floor, min. 6" from wall, max. 48" from floor.
Correction

WU - Sanitary sewer riser diagram indicates that the new indirect waste connections (27), (16), (19), (12), (24), (25) and (17) are being connected the grease interceptor line. All of these connections must connect to the sanitary sewer line.
Correction

Codes Administration - For canopy type cooking hoods, the inside edge therof shall overhang or extend a horizontal distance of not less than six inches (6") beyond the edge of the cooking surface on all open sides. 1191 Uniform Mechanical Code Section 2003(f).
Correction

Codes Administration - Each room with an exhaust system shall have air supplied to the room equal to the amount of air to be exhausted. 1991 Uniform Mechanical Code Section 2003(i).
Correction

Codes Administration - Additions, alterations, repairs and replacement of equipment or systems shall comply with the provisions for new equipmant and systems. 1991 Uniform Mechanical Code Section 103.
Correction

Fire Department- Fire-protection equipment and fire hydrants shall be clearly identified in a manner approved by the chief to prevent obstruction by parking and other obstructions. (UFC Section 10.105b)
Correction

Fire Department- Approved numbers or address shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Said numbers shall contrast with their background. (UFC Section 10.301.(a))
Correction

Fire Department- The duct detectors when activated shall be received at the panel and alarm company as a trouble alarm. (UFC Section 10.503.)
Correction

Fire Department- Fire alarm systems; fire hydrant systems; fire-extinguishing systems, including automatic sprinklers and wet and dry standpipes; halon systems and other automatic fire-extinguishing systems shall meet the approval of the fire department as to installation and locations and shall be subject to acceptance testing and such periodic testing as required by the chief. NOTE: Acceptance testing may scheduled at least 48 hours in advance by calling 969-7343. UFC 10.503
Correction

Fire Department- Fire-protection or extinguishing system coverage, spacing and specifications shall be maintained accordance with recognized standards at all time. Such systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever any building so equipped is altered, remondeled or added to. Additions, repairs, alterations and servicing shall be in accordance with recognized standards. UFC Section 10.504(a)
Correction

Fire Department- Portable fire extiguishers shall be installed in occupancies and locations as set forth in the Uniform Fire Code Standards and as required by the Chief. Extinguishers shall be mounted in a conspicuous place with travel distance between any point in the building and extinguisher not to exceed 75 feet. Extinguishers shall be a minimum of 2A-10BC (5 lb.). (UFC Section 10.505.(a))
Correction

Fire Department- Approved fire suppression systems shall be provided for the protection of commercial food heat-processing equipment that produces grease laden vapors. The system installed to protect ventilating hoods and ducts and cooking appliances shall be installed to include cooking surfaces, deep fat fryers, griddles, upright broilers, charbroilers, range tops and grills. Protection shall also be provided for the enclosed plenum space within the hood above filters and exhaust ducts serving the hood. UFC 10.513
Correction

Fire Department- All locksets, both new and existing shall be openable from the inside without the use of a key, special tool or knowledge. (UFC.12.106)
Correction

Fire Department- Exit doors shall be operable from the inside without the use of a key or any special knowledge. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC Section 12.106.(c))
Correction

Fire Department- Exit illumination shall be provided and maintained in accordance with the Building Code. Exits shall be illuminated when the building or structure is occupied. Equipment providing emergency power for exit illumination and exit signs shall be maintained in an operable condition. (UFC Section 12.110)
Correction

Fire Department- If building alteration adversely effects exit illumination, exit illumination shall be provided and maintained in accordance with the Building Code. UFC Section 12.110.(A).
Correction

Fire Department- When two or more exits from a story are required, exit signs shall be installed ar stair enclosure doors, horizontal exits and other required exits from the story. When two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicated the direction of egress. Exit signs shall be illuminated either internally or externally in accordance with the Building Code. Where emergency power supplies are required for exit illumination, exit signs shall be illuminated by emergency power. (UFC Section 12.111)
Correction

Fire Department- Extension cords shall not be utilized as a substitute for permanent wiring. Extension cords shall only be utilized with portable appliances while such appliances are in use and shall only supply one portable appliance except for approved multi-plug extension cords. Extension cords shall be grounded when serving grounded appliances. Extension cords and multi-plug extension cords shall not be affixed to structures; extened through walls, ceilings, floors, under doors or floor coverings; or be subject to environmental or physical damage. (UFC Section 85.106.(a), (b) and (c))
Correction

Fire Department- During construction fire department access shall be maintained and not obstructed. UFC Section 87.103.(b)
Correction

Fire Department- Combustible debris shall not be accumulated within buildings. Combustible debris, rubbish and waste material shall be removed from buildings as often as practicl. Combustible debris, waste material and trash shall not be burned on site. UFC Section87.103.(e)
Correction

Codes Administration- No cold storageroom, cooling counter, compartment, receptacle, apurtenance, or device which is used, designed, or intended to be used for the storage or holding of food or drink and no dishwashing or culinary sink in any food preparation room which is used for soaking, washing, or preparing ready to serve food shall have any drain in connection therewith directly connected to any soil, waste, or vent pipe. Such equipment of fixtures shall be drained by means of indirect wast pipes, as defined in Chapter 1 of this Code, and all wastes drained by them shall discharge through an airgap into an open floor sink or other approved type receptor which is properly connected to the drainage system. (UPC Section 601)
Correction

Codes Administration- The airgap-drainage shall be not less than one (1) inch between the plumbing fixture, appliance or appurtenance outlet and the rim of the floor sink or receptor. (1991 Uniform Plumbing Code, Section 601.(c).)
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $557.00 $557.00 Paid 02/22/2001
24 BLDG Plan Check Fees $29.25 $29.25 Paid 02/22/2001
25 Electrical Permit Fee $98.11 $98.11 Paid 02/22/2001
25 Mechanical Permit Fees $21.50 $21.50 Paid 02/22/2001
25 Plumbing Permit Fees $107.00 $107.00 Paid 02/22/2001
89 Sewer Tap Fees $120.00 $120.00 Paid 02/22/2001
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections

There are no inspections for this permit application.

Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents