Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 05/09/2001 10/29/2010
Correction

Codes Administration- No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

Codes Administration- Each structure shall have the address of that structure visibly posted on the jobsite throughout the construction process.
Correction

Codes Administration- A completed License Tax application must be submitted to the City of Lee's Summit and any applicable License Tax paid prior to issuing a building permit.
Correction

Codes Administration - It shall be unlawful for any person to engage in any business or manufacturing within the City without first having obtained a license therefor, paying the license fee, and registering the business or manufacturer with the Director of Finance or the Director's representative. (Lee's Summit Code of Ordinances, Section 28-24.) It is the general contractors responsiblity to make sure that all the trades on their project are licensed with the City of Lee's Summit.
Correction

Codes Administration- The engineer or architect in responsible charge of the structural design work shall include in the construction documents the special inspections required by UBC section 306 and other structural inspections required by the engineer or architect. (UBC Section 302.(c))
Correction

Codes Administration- It shall be the duty of the person doing the work authorized by a permit to notifiy the Building Inspections Division that such work is ready for inspection. (UBC Section 305.(c))
Correction

Codes Administration- The special inspector shall observe the work assigned for conformance, shall furnish inspection reports to the Codes Administration Department and the engineer or architect of record and shall submit a final signed report stating whether the work requiring special inspection was in conformance with the approved plans and applicable sections of this code. The final report shall be submitted prior to receiving a Certificate of Occupancy. (UBC Section 306.(c))
Correction

PW - Contact Public Works Inspection at 969-7450 prior to construction.
Correction

PW - Contact Barton Reese, Erosion Control Specialist, at 969-7951 for erosion control installation approval and prior to land disturbance.
Correction

PW - Please submit three (3) sets of revised civil site plans to Public Works Engineering containing the information necessary to address the Water Utilities and the Public Works Engineering Departments comments.
Correction

PW - Provide a copy of the Land Disturbance Permit application and the required attachments to the Erosion Control Specialist prior to any land disturbance activities that are to occur prior to obtaining a building permit.
Correction

PW - Re-submit the pavement design for the west entrance driveway. The pavement design indicated for the west entrance driveway on sheets C-1 and C-5 does not comply with City's standard detail SD-18 from City Ordinance No. 3719.
Correction

PW - Provide documentation and construction limits for the proposed offsite improvements.
Correction

PW - Provide complete civil site plans as per previous submittals. The civil site plan dated November 1, 2000 had sheets missing.
Correction

WU - The sanitary sewer service connection must be removed and capped at the public sanitary sewer main by the contractor.
Correction

WU - The existing domestic water service along Grand must be removed and plugged at the water main by the contractor.
Correction

WU - Contractor must give 24 hour notification to Public Works Inspections before removal of the sanitary sewer service connection and before removal/plugging the water service line connection.
Correction

P&D - Ground Mounted Equipment - Indicate the location of all ground mounted equipment and indicate how each location is screened on the landscape plan.
Correction

P&D - Free standing lighting - Indicate the type of metal halide lighting fixture, flush lens, candlepower and height of pole and fixture height.
Correction

P&D - Canopy Lighting - Indicate the type of canopy lighting proposed. Provide cut sheet specification of the "G" light fixture and how it is screened to prevent fugitive light beyond the property line.
Correction

P&D - Visibility Triangle - Indicate the 20 ft by 250 ft visibility triangle at all existing and proposed driveways on the site and at Johnson and Grand Avenue (based on the speed limit of Third Street as 35 mph).
Correction

P&D - Landscape Worksheet - Revise the required and provided units and provide calculation for each as per ordinance requirements.
Correction

P&D - Aisle Width - provide the width of the one way aisle between the existing parking and the proposed parking east of the building. Indicate the dimension from the edge of each rectangular parking space.
Correction

P&D - Minor Plat - The minor plat was picked up to be recorded on Oct. 30, 2000. The plat must be recorded prior to issuance of any building permit.
Correction

P&D - Free standing lighting - Exterior free standing lighting shall not exceed 20 ft in height and shall not exceed 400 wates and shall include cut-off shields.
Correction

P & D - All development shall be in accordance with the final site plan approved by City Council on October 5, 2000, including all conditions in staff's letter dated September 27, 2000.
Correction

Fire Department- Fire apparatus access roads shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. (UFC Section 10.204.(a))
Correction

Fire Department- Parking lots and fire apparatus access roads shall be designed and maintained to support the imposed loads of fire apparatus and shall be provided with a surface so as to provide all-weather driving capabilities. (UFC Section 10.204.(b))
Correction

Fire Department- Approved numbers or address shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Said numbers shall contrast with their background. (UFC Section 10.301.(a))
Correction

Fire Department- Extension cords shall not be utilized as a substitute for permanent wiring. Extension cords shall only be utilized with portable appliances while such appliances are in use and shall only supply one portable appliance except for approved multi-plug extension cords. Extension cords shall be grounded when serving grounded appliances. Extension cords and multi-plug extension cords shall not be affixed to structures; extened through walls, ceilings, floors, under doors or floor coverings; or be subject to environmental or physical damage. (UFC Section 85.106.(a), (b) and (c))
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Passed 06/18/2002
Correction
Resolved
06/18/2002
GENERAL INFORMATION ONLY SCOPE OFBWORK HAS NOT BEGUN PERMIT HAS EXPIRED CLOSE/VOID PERMIT BUILDER TO OBTAIN NEW PERMIT IF WORK IS TO BE INITIATED
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home