Summary
B0000012
Building Permit - Commercial
Certificate of Occupancy
REORGANIZED SCHOOL DIST NO 7
ADDITION COMMERCIAL
LS NORTH HIGH SCHOOL ADDITION
01/04/2000
03/24/2000
09/20/2000
12/11/2001
Locations
Contacts
LICO CONSTRUCTION, Address:9301 EAST 47TH ST  
REORGANIZED SCHOOL DIST NO 7, Address:600 SE MILLER  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/02/2000 10/29/2010
Correction

Codes Administration- No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

Codes Administration- Erosion control shall be provided in conformance with Article VIII, Section VIII(c) & (d) and details 48 and 48A of the City of Lee's Summit Design and Construction Manual. Erosion control devices shall be installed and maintained during all phases of the construction process. Failure to provide or maintain erosion control may result in an issuance of a stop work order which is authorized by Article I, Section XXIV.
Correction

Codes Administration- Each structure shall have the address of that structure visibly posted on the jobsite throughout the construction process.
Correction

Codes Administration- A completed License Tax application must be submitted to the City of Lee's Summit and any applicable License Tax paid prior to issuing a building permit.
Correction

Codes Administration - Each layer of fire-resistive assemblies shall be inspected and approved prior to the application of additional layers or finishes. All firestopping of penetrations and required dampers shall be inspected and approved prior to concealing.
Correction

Codes Administration- It shall be the duty of the person doing the work authorized by a permit to notifiy the Building Inspections Division that such work is ready for inspection. (UBC Section 305.(c))
Correction

Codes Administration- Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the Building Official. The Building Official, upon notification, shall make the requested inspections and shall either indicate that portion of the construction is satisfactory as completed, or shall notify the permit holder or an agent of the permit holder wherein the same fails to comply with this code. Any portions which do not comply shall be corrected and such portion shall not be covered or concealed until authorized by the Building Official. (1991 Uniform Building Code, Section 305.(d).)
Correction

Codes Administration- A reinspection fee may be assessed for each inspection or reinspection when such portion of work for which inspection is called is not complete or when corrections called for are not made. ( UBC Section 305.(g))
Correction

Codes Administration- A reinspection fee may be assessed if an approved set of plans are not readily available to the inspector and the permit card is not posted at the time of the inspection. (UBC Section 305.(g))
Correction

Codes Administration- The special inspector shall observe the work assigned for conformance, shall furnish inspection reports to the Codes Administration Department and the engineer or architect of record and shall submit a final signed report stating whether the work requiring special inspection was in conformance with the approved plans and applicable sections of this code. The final report shall be submitted prior to receiving a Certificate of Occupancy. (UBC Section 306.(c))
Correction

Fire Department- Two and one-half inch hose connections (standpipes) shall be provided at the following exit doors: 100, 105 and P100.
Correction

Fire Department- The duct detectors when activated shall be received at the panel and alarm company as a trouble alarm. All other functions of the detector including unit shutdown (as noted in the mechanical plan) shall remain the same. (UFC Section 10.503.)
Correction

Codes Administration - Provide details on the one hour assembly at the bottom of the mechanical shaft at the floor/ceiling level. (Located between restrooms 212 and 213)
Correction

Codes Administration - Where corridor walls are required to be of one-hour fire-resistive construction by Section 3305(g), interior openings for other than doors or ducts shall be protected by fixed glazing listed and labeled for a fire-protection rating of at least three-forths hour in accordance with Section 4306(i). The total area of all openings, other than doors, in any portion of an interior corridor shall not exceed 25 percent of the are of the corridor wall of the room which it is seperating from the corridor. (1991 Uniform Building Code, Section 3305(h)2.)
Correction

Codes Administration - Provide manufactors cut sheets on the horizontal sliding fire door. (This is in addition to the code information already supplied.) Two copies shall be supplied to the City prior to installation of the doors.
Correction

Codes Administration - Provide manufactors cut sheets on the rolling shutter door. Two copies shall be provided to the City prior to installation.
Correction

Codes Administration - The fire rating table on sheet G101 shows that the structural frame and the roof/ceiling assembly does not have a fire rating but table 17-A of the 1991 Uniform Building Code shows that 1-hr rated protection is required. Indicated why you do not show protection on the structural frame.
Correction

Codes Administration - The maximum number of fixture units allowed on a 4" drain line is 216 per table 4-3 of the 1991 Uniform Plumbing Code. The number of fixture units in the south two story addition is 293. The size of the drain line will have to be increased, the number of fixture units will have to be decreased or you will have to provide an alternate solution to provide proper drainage.
Correction

Codes Administration - Provide the manufactors cut sheets on the 5 gallon neutralization tanks being installed under the chemistry sinks.
Correction

Codes Administration - I am unable to find a window schedule for this project. Please indicate where it can be found or provide one if it is not included.
Correction

Codes Administration - Provide two copies of the steel package drawings once you have received them.
Correction

Codes Administration - Exit signs shall be installed on both sides of the horizontal exit doors so that they are visable once the doors have shut.
Correction

Fire Department- Fire alarm systems; fire hydrant systems; fire-extinguishing systems, including automatic sprinklers and wet and dry standpipes; halon systems and other automatic fire-extinguishing systems shall meet the approval of the fire department as to installation and locations and shall be subject to acceptance testing and such periodic testing as required by the chief. NOTE: Acceptance testing may scheduled at least 48 hours in advance by calling 969-7343. UFC 10.503
Correction

Codes Administration - Signs shall be installed on the doors to the existing southeast stair enclosure stating that it is not an exit.
Correction

Codes Administration - Provide information on how the exiting will be maintained during construction.
Correction

Codes Administration - During the preliminary meetings the City stated that they wanted hold open devices on doors 112/2 and 113/3 that would release upon activation of the fire alarm system. I do not see these indicated in the plans or specifications.
Correction

Codes Administration - Provide details on the 1-hour fire-rated roof/ceiling assemblies used in the various areas of the additions.
Correction

Codes Administration - Explain the use of plywood in the roof assembly of the Biology Prep. Room.
Correction

PLANNING & DEVELOPMENT - No "overall" site plan was submitted with the plans. A site plan showing the proposed additions and the existing building and the surrounding site information must be submitted with the revised plans.
Correction

PLANNING & DEVELOPMENT - No new trash enclosures are proposed on the plan. If new trash enclosures are proposed, a detail drawing with approved screening materials of the trash enclosure must be submitted for approval.
Correction

PLANNING & DEVELOPMENT - The ordinance requires that all roof or ground mounted mechanical equipment proposed must be screened so that it is not visible from any public right-of-way or residentially-zoned area, as required by the ordinance. It is not clear from the submitted plans if this requirement is met. The elevations and roof plan appears to show adequate screening of all roof top units. However, a more detailed drawing would be required for staff to conduct a thorough analysis. Submit a line-of-sight study or a detailed drawings (sections/details, etc.) showing the type of screening and the height of the new roof top units. This requirement must be met.
Correction

PLANNING & DEVELOPMENT - No new exterior lighting (wall-packs & parking light poles) are proposed/shown. If exterior lighting is proposed, a lighting plan, including the manufacturer's specifications on all exterior lights proposed must be submitted and approved by the Department of Planning & Development.
Correction

PLANNING & DEVELOPMENT - It is not clear if the parking requirement is met with the proposed building addition. Is parking well within the requirements of the ordinance with the proposed addition? On the requested site plan, include a table/chart showing the required parking spaces and proposed/additional parking spaces, if any. This information must be provided.
Correction

PLANNING & DEVELOPMENT - No tree protection/landscape plan was submitted for review as required. The ordinance requires that a tree protection/landscape plan be submitted for the "disturbed area."
Correction

PLANNING & DEVELOPMENT - No "overall" site plan was submitted with the plans. A site plan showing the proposed additions and the existing school building (and pertinent surrounding site information---internal sidewalks, etc.) must be submitted with the revised plans.
Correction

Fire Department- A set of sprinkler plans and specifications bearing a State of Missouri licensed engineers seal, shall be submitted to the Fire Department for review and approval prior to construction (system modification). (1991 Uniform Fire Code, Section 10.503)
Correction

Fire Department- Fire-protection or extinguishing system coverage, spacing and specifications shall be maintained accordance with recognized standards at all time. Such systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever any building so equipped is altered, remondeled or added to. Additions, repairs, alterations and servicing shall be in accordance with recognized standards. UFC Section 10.504(a)
Correction

Fire Department- If building alteration adversely effects exit illumination, exit illumination shall be provided and maintained in accordance with the Building Code. UFC Section 12.110.(A).
Correction

Fire Department- If building alteration causes current exit signs to no longer pertain, exit signs shall be removed and placed in new location to indicate new exit passageway. UFC Section 12.(a).
Correction

Fire Department- During construction fire department access shall be maintained and not obstructed. UFC Section 87.103.(b)
Correction

Fire Department- During construction required exit components shall be maintained. UFC Section 87.101.(c)
Correction

Fire Department- During construction and alteration fire-resistive assemblies and construction shall be maintained in accordance with Section 10.602. and 10.602. UFC Section 87.104.(d)
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $12,227.00 $12,227.00 Paid 03/24/2000
24 BLDG Plan Check Fees $223.75 $223.75 Paid 03/24/2000
25 Electrical Permit Fee $299.00 $299.00 Paid 03/24/2000
25 Mechanical Permit Fees $318.50 $318.50 Paid 03/24/2000
25 Plumbing Permit Fees $266.50 $266.50 Paid 03/24/2000
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections

There are no inspections for this permit application.

Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home